Permit Application Status

PRRES20215344


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215344
Building Permit - Residential
Certificate of Occupancy
NLV PERGOLA PARK LLC
NEW SINGLE FAMILY
NEW HOUSE. COVERED DECK. ROOFTOP DECK.
10/12/2021
11/15/2021
05/01/2022
02/28/2024
Locations
Contacts
LANDROCK SIGNATURE HOMES LLC, Address:4335 MCGEE ST, Phone:(816) 863-5588  
JP Roberts, Address:4335 McGee St  
NLV PERGOLA PARK LLC, Address:3152 SW GRANDSTAND CIR  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
JP@LANDROCKKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $540.00 $540.00 Paid 11/15/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 11/15/2021
Water Meter Fee $479.24 $479.24 Paid 11/15/2021
Right of Way Permit Fee $85.00 $85.00 Paid 11/15/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/15/2021
Valuation Fee New Single Family $1,388.38 $1,388.38 Paid 11/15/2021
Temporary Occupancy Fee $50.00 $50.00 Paid 11/17/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 1/31/2022 1/31/2022 01/31/2022
Sewer Service Inspection - R Passed 2/8/2022 (10:45) 2/8/2022 02/08/2022
Water Service Inspection - R Partial 2/8/2022 (10:45) 2/8/2022 02/08/2022
Miscellaneous Correction
Corrective Action Required
02/08/2022
Tap across street not complete. Pex from foundation approved
Water Service Inspection - R Passed 2/9/2022 02/09/2022
Miscellaneous Correction
Resolved
02/09/2022
Erosion Control Inspection Residential Failed 2/9/2022 02/09/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/09/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. clean street Repair silt fence
Erosion Control Inspection Residential Failed 5/24/2022 05/24/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/09/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. clean street Repair silt fence
Misc
Corrective Action Required
05/24/2022
Silt fence needs repaired around property, but especially in back where draining into alley way. 5/24/22 ES
All Rough Inspection - Residential Failed 8/5/2022 8/5/2022 08/05/2022
Miscellaneous Correction
Corrective Action Required
08/05/2022
post address Provide anchor bolt 12” from end of plate garage left side below window Sister stud at over notched stud garage right of window Solid block cantilever at patio Security blocking at sliding door Install fire place and plumb Vent fire place Add hanger to double LVL front porch Complete vent plumbing above master bathroom Complete vent ductwork master bathroom Patch floor master bathroom Address over notched joist at laundry Address over bored studs DWV exterior wall at stairs Complete DWV threw roof upstairs Upstairs bathroom vent needs ductwork Fire block upstairs tub at plumbing Provide guard roof deck Steel column missing in basement Anchor all steel columns
Electrical Service Inspection Passed 8/5/2022 8/5/2022 08/05/2022
Gas Service Inspection - Residential Failed 8/5/2022 8/5/2022 08/05/2022
Misc
Corrective Action Required
08/05/2022
plumb fire place and subimt re inspection.
Gas Service Inspection - Residential Passed 8/10/2022 8/10/2022 08/10/2022
Misc
Resolved
08/10/2022
All Rough Inspection - Residential Failed 8/10/2022 8/10/2022 08/10/2022
Miscellaneous Correction
Corrective Action Required
08/05/2022
Address over bored studs DWV exterior wall at stairs Complete roof boots OK to insulate
Footing Inspection - Residential Passed 8/12/2022 08/12/2022
Misc
Informational
08/12/2022
Third party inspection completed.
All Rough Inspection - Residential Passed 8/12/2022 8/12/2022 08/12/2022
Miscellaneous Correction
Resolved
08/12/2022
Sidewalk Inspection Partial 9/7/2022 9/7/2022 09/07/2022
Misc
Informational
09/07/2022
Sidewalk was framed up with aggregate in and compacted. 9/7/22 ES
Sidewalk Inspection Passed 9/15/2022 9/15/2022 09/16/2022
Misc
Informational
09/07/2022
Sidewalk was framed up with aggregate in and compacted. 9/7/22 ES Sidewalk meets LS and ADA spec. 9/16/22 ES
Occupancy Inspection - Codes Residential Failed 11/14/2022 11/14/2022 11/14/2022
Misc
Corrective Action Required
11/14/2022
NO INSPECTION PERFORMED, -POST ADDRESS
Occupancy Inspection - Codes Residential Failed 11/15/2022 11/15/2022 11/15/2022
Misc
Resolved
11/15/2022
NO INSPECTION PERFORMED, -POST ADDRESS
Misc
Corrective Action Required
11/15/2022
-sod -splash blocks and sump pump discharge to extend 36” from foundation -obtain lawn irrigation permit -complete kitchen to provide place to cook and prepare food -wall boxes hanging from NM wire -guard rail at garage stairs and steps -garage outlets higher than 5.5 -back flow device at water spigot in basement -label all non GFCI outlets in unfinished spaces -complete gas at water heater -cover blanks in service panel -gutters for scuppers -provide as graded plot plan or grade to plans -uncover covered manhole
Occupancy Inspection - Codes Residential Ready for Temp CO 11/17/2022 11/17/2022 11/17/2022
Misc
Corrective Action Required
11/15/2022
-sod -splash blocks and sump pump discharge to extend 36” from foundation -obtain lawn irrigation permit -Pending sidewalk inspection -gutters for scuppers -provide as graded plot plan or grade to plans -uncover covered manhole
Plot Plan Inspection Passed 10/11/2023 10/11/2023
Erosion Control Inspection Residential Passed 10/11/2023 10/11/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/11/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. clean street Repair silt fence
Misc
Resolved
10/11/2023
Silt fence needs repaired around property, but especially in back where draining into alley way. 5/24/22 ES
Occupancy Inspection - Codes Residential Failed 12/17/2022 10/11/2023
Misc
Corrective Action Required
11/17/2022
-obtain lawn irrigation permit -
Occupancy Inspection - Codes Residential Full C of O 02/28/2024
Misc
Resolved
02/28/2024
-obtain lawn irrigation permit -
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home