Summary
PRRES20214938
Building Permit - Residential
Certificate of Occupancy
KEVIN HIGDON CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK - SUSPENDED STOOP
09/21/2021
10/04/2021
03/27/2022
12/28/2023
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
KEVIN@HIGDONBUILDERS.COM  
KEVIN HIGDON CONSTRUCTION LLC, Address:1450 SE BROADWAY DR  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE ELECTRICAL CONSTRUCTION, Address:3710 ROBINSON PIKE RD, Phone:(816) 761-0200  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
KEVIN HIGDON CONSTRUCTION LLC, Address:1450 SE BROADWAY DR  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/04/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/04/2021
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 10/04/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 10/04/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/04/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/04/2021
9110078-Valuation Fee New Single Family $1,073.48 $1,073.48 Paid 10/04/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/23/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Partial 11/16/2021 11/16/2021 11/16/2021
Misc
Corrective Action Required
11/16/2021
UPLOAD ENGINEER REPORT THAT WAS ON SITE AT INSPECTION CONCERNING SOIL CONDITIONS FOR FOOTING
Water Service Inspection - R Partial 11/30/2021 (8:30) 11/30/2021 11/30/2021
Sewer Service Inspection - R Partial 12/1/2021 (10:00) 12/1/2021 12/01/2021
Misc
Informational
12/01/2021
PARTIAL INSPECTION ON SEWER FROM FOUNDATION APPROX 40' TO SW AT REAR OF HOUSE
Sewer Service Inspection - R Passed 12/2/2021 (9:15) 12/2/2021 12/02/2021
Misc
Resolved
12/02/2021
PARTIAL INSPECTION ON SEWER FROM FOUNDATION APPROX 40' TO SW AT REAR OF HOUSE
Water Service Inspection - R Passed 12/2/2021 (11:15) 12/2/2021 12/02/2021
Underslab Plumbing Inspection - Residential Failed 1/4/2022 1/4/2022 01/04/2022
Misc
Corrective Action Required
01/04/2022
-INTERIOR DRAIN TILE, IF NO SUMP PUMP WITH WALKOUT INTERIOR DRAIN TILE MUST DRAIN TO DAYLIGHT
Underslab Plumbing Inspection - Residential Passed 1/12/2022 1/12/2022 01/12/2022
Misc
Resolved
01/12/2022
Electrical Service Inspection Passed 5/18/2022 05/18/2022
Erosion Control Inspection Residential Partial 5/18/2022 5/18/2022 05/18/2022
Gas Service Inspection - Residential Failed 5/18/2022 05/18/2022
Misc
Corrective Action Required
05/18/2022
-Complete gas line install at fireplace
All Rough Inspection - Residential Failed 5/18/2022 05/18/2022
Misc
Corrective Action Required
05/18/2022
-provide nailing pattern 3” grid at garage door PFH per plans/IRC R602.10.6.2 -Provide anchor bolt per code at garage PFH portal -12” oc nailing all abutting corners -Have engineer address rafters on blocks above ceiling joist -provide bocca protection plate at DWV garage wall/pantry top plate -support hips -have engineer address hips landing on blocks above top plate -provide security block rear deck door -address top plate to top plate lap corner connection at great room 2x6 exterior wall -complete gas line install at fireplace -fireblock fireplace lid -provide dbl joist hanger above basement stairs foyer -support ridge at ends front bedroom -solid block all sheathing breaks -provide joist hangers at ceiling joist master bath and front bed closet -Fireblock deadspace behind front bath tub -see plans garage note at dbl car bay, 2-2x10 upset -Provide CS-PF portal bracing design per plans at breakfast/kitchen -Have engineer address dbl 2x12 beams at covered deck landing on blocks for bearing, ceiling joists notched around beam -GB method of interior wall bracing will require screw pattern inspection after given the go ahead for insulation/rock -min 24” lap between dbl top plate breaks, see great room -provide joist hangers at joists, basement stairs, basement bed hall -UFER must remain accessible at finish -secure ward flex gas line span across joist at basement den at least 3” from end of joist, at steel beam will need to fur down for gas line, ensure that bend radius is not more than what is allowed by manufacturer
Gas Service Inspection - Residential Failed 6/22/2022 6/22/2022 06/22/2022
Misc
Corrective Action Required
05/18/2022
-Gas pressure 3 psi, must maintain 10 psi for test
All Rough Inspection - Residential Passed 6/22/2022 6/22/2022 06/22/2022
Misc
Resolved
06/22/2022
Erosion Control Inspection Residential Partial 6/22/2022 6/22/2022 06/22/2022
Gas Service Inspection - Residential Passed 6/24/2022 6/24/2022 06/24/2022
Misc
Resolved
06/24/2022
Driveway Inspection Partial 7/20/2022 7/20/2022 07/20/2022
Misc
Informational
07/20/2022
7.20.2022. I conducted a Driveway inspection and pass the sub-grade to pour concrete
Driveway Inspection Passed 8/8/2022 8/8/2022 08/08/2022
Misc
Informational
07/20/2022
7.20.2022. I conducted a Driveway inspection and pass the sub-grade to pour concrete 8.8.2022 Driveway appears to be compliant
Occupancy Inspection - Codes Residential Failed 9/22/2022 9/22/2022 09/22/2022
Misc
Corrective Action Required
09/22/2022
-Upload engineer letter to portal from footing concerning soil conditions -no pier inspection performed, submit engineer letter -final grade and sod -splash blocks -downspouts and gutters -provide gravel base at water meter pit -complete top tread of flight basement stairs, more than 3/8” variance from stairs rises -provide AFCI protection at office circuit -provide access for UFER ground -properly support outer beams of covered deck at house
Piers/Caissons Inspection - Residential Failed 9/22/2022 9/22/2022 09/22/2022
Misc
Corrective Action Required
09/22/2022
NO PIER INSPECTION PERFORMED, SUBMIT ENGINEER LETTER
Footing Inspection - Residential Passed 9/23/2022 9/23/2022 09/23/2022
Misc
Resolved
09/23/2022
UPLOAD ENGINEER REPORT THAT WAS ON SITE AT INSPECTION CONCERNING SOIL CONDITIONS FOR FOOTING
Piers/Caissons Inspection - Residential Passed 9/23/2022 9/23/2022 09/23/2022
Misc
Resolved
09/23/2022
NO PIER INSPECTION PERFORMED, SUBMIT ENGINEER LETTER
Occupancy Inspection - Codes Residential Ready for Temp CO 9/23/2022 9/23/2022 09/23/2022
Misc
Corrective Action Required
09/22/2022
-final grade and sod -splash blocks -downspouts and gutters -provide gravel base at water meter pit
Occupancy Inspection - Codes Residential Temporary C of O 09/23/2022
Misc
Corrective Action Required
09/23/2022
-final grade and sod -splash blocks -downspouts and gutters -provide gravel base at water meter pit
Occupancy Inspection - Codes Residential Failed 10/19/2022 10/19/2022 10/19/2022
Misc
Corrective Action Required
09/23/2022
-PROVIDE SPLASH BLOCKS ALL DOWNSPOUT AND SUMP PUMP DISCHARGE LOCATIONS, MIN 36" DISCHARGE FROM FOUNDATION -REMOVE ALL CONSTRUCTION DEBRIS AND TRASH AT REAR OF LOT
Erosion Control Inspection Residential Passed 10/19/2022 10/19/2022 10/19/2022
Plot Plan Inspection Passed 10/19/2022 10/19/2022 10/19/2022
Occupancy Inspection - Codes Residential Failed 8/7/2023 08/07/2023
Misc
Corrective Action Required
10/19/2022
SUMP PUMP DISCHARGE LOCATIONS, MIN 36" DISCHARGE FROM FOUNDATION
Occupancy Inspection - Codes Residential Full C of O 12/28/2023 12/28/2023
Misc
Resolved
12/28/2023
SUMP PUMP DISCHARGE LOCATIONS, MIN 36" DISCHARGE FROM FOUNDATION
Documents & Images
Date Uploaded File Type Document Name
09/21/2021 Application Form APPLICATION
09/21/2021 Application Form EXCISE TAX APP.
09/21/2021 Approved Plans approved plans
09/21/2021 Permit Codes Residential Plan Review
09/23/2021 LOT 133A CON 9-23-21
09/24/2021 Permit Codes Residential Plan Review
09/28/2021 Permit Codes Residential Plan Review
10/04/2021 Plot Plan APPROVED PLOT PLAN
10/04/2021 Permit Codes Residential Plan Review
10/04/2021 Permit DS Building Permit
10/04/2021 Receipt Receipt for transaction:2021-007746
11/16/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
12/01/2021 Letter INSPECTION SUMMARY
12/02/2021 Letter INSPECTION SUMMARY
12/02/2021 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
06/21/2022 Engineer Report/Study Engineer Letter
06/22/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/22/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
09/22/2022 Letter INSPECTION SUMMARY
09/22/2022 Letter INSPECTION SUMMARY
09/22/2022 Engineer Report/Study 1519 SW BLACKSTONE PL SOIL
09/22/2022 Engineer Report/Study 1519 SW Blackstone Pl_DECK PIER INSP_2022-07-20
09/23/2022 Letter INSPECTION SUMMARY
09/23/2022 Letter INSPECTION SUMMARY
09/23/2022 Receipt Receipt for transaction:2022-007764
09/23/2022 Letter Codes Temporary Certificate of Occupancy
10/19/2022 Letter INSPECTION SUMMARY
10/19/2022 Letter INSPECTION SUMMARY
10/19/2022 Letter INSPECTION SUMMARY
08/07/2023 Letter INSPECTION SUMMARY
08/07/2023 Letter INSPECTION SUMMARY
12/28/2023 Letter Codes Final Certificate of Occupancy
12/28/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home