Summary
PRRES20214712
Building Permit - Residential
Certificate of Occupancy
KEVIN HIGDON CONSTRUCTION LLC
NEW 3 OR 4 FAMILY
NEW THREE-PLEX - UNFINISHED BASEMENT - COVERED DECK - ROOF TRUSSES. *790 AND 794 NE ALGONQUIN HAS BASEMENT FINISH ONLY.
09/08/2021
09/16/2021
03/09/2022
07/21/2023
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
DOUG@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $2,594.26 $2,594.26 Paid 09/16/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/16/2021
8331507-Sewer Connection Fee $900.00 $900.00 Paid 09/16/2021
8331401-Water Tap Fee $10,965.00 $10,965.00 Paid 09/16/2021
8350015-Water Meter Fee $1,437.72 $1,437.72 Paid 09/16/2021
8331506-EFHB Maybrook, Full $1,278.30 $1,278.30 Paid 09/16/2021
7232302-Residential License Tax Fee $3,231.36 $3,231.36 Paid 09/16/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 12/30/2022
9110078-Valuation Fee New Single Family $443.69 $443.69 Paid 12/30/2022
$3,037.95
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/27/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/09/2023
9110078-Valuation Fee for New 3 or 4 Family $51.12 $51.12 Paid 03/31/2023
$3,089.07
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/05/2023
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/19/2021 (1:30) 10/19/2021 10/19/2021
Sewer Service Inspection - R Partial 11/3/2021 (1:30) 11/3/2021 11/03/2021
Misc
Informational
11/03/2021
SEWER FOR UNIT 790-OK
Sewer Service Inspection - R Passed 11/4/2021 11/04/2021
Misc
Informational
11/03/2021
SEWER FOR UNIT 790->794-OK
Water Service Inspection - R Passed 11/8/2021 (1:00) 11/8/2021 11/08/2021
Misc
Corrective Action Required
11/08/2021
Water service for 790-794 OK
Underslab Plumbing Inspection - Residential Not Ready 11/29/2021 11/29/2021 11/29/2021
Underslab Electrical Inspection - Residential Passed 12/9/2021 12/9/2021 12/09/2021
Underslab Plumbing Inspection - Residential Failed 12/9/2021 12/9/2021 12/09/2021
Misc
Corrective Action Required
12/09/2021
-PROVIDE CONTINUOUS GRAVEL SUPPORT
Rated Assembly Inspection Failed 5/13/2022 5/13/2022 05/13/2022
Misc
Corrective Action Required
05/13/2022
**See allrough inspection
All Rough Inspection - Residential Failed 5/13/2022 5/13/2022 05/13/2022
Misc
Corrective Action Required
05/13/2022
**SHALL CLEAN UP THE CHAPEL RIDGE STREET AND INSTALL EROSION CONTROL ALONG THE STREET UNIT 790: -Strap and nail top plates lapped less than two ft at front bathroom -Nail together girder truss per truss detail; provide full support at exterior wall end; tie down girder truss to wall -Install ducting to bath fan -Fill in gap at exterior door hinges and strike plate side with solid wood per security code -Nail corner studs per code -Connect gas line to fireplace -Complete electrical to fireplace -Fb gap between FlameBlock and firewall in attic above rear dining -Cover roof deck hole above rear dining with GB or FlameBlock -Drain vent piping in attic toward drain -Brace firewall -Close hole at bottom wall plate in laundry -Toe nail all joists to sill plates and top plates in basement with 4-8d or 3-10d -S-traps not allowed. Vent connections shall not be below trap weirs -Reinstall blockings of joists at basement window UNIT 792: -Fb gap between roof deck and firewall -Nail together girder truss per truss detail; provide full support at firewall end; tie down girder truss to wall -Connect duct to master bathroom fan; complete ducting to outdoor -Install blocking and fasten firewall to framing at master bathroom -Provide min 4 ft of roof deck fire protection from firewall -Engineer to address repair of damaged truss above master bathroom -Fill in gap at exterior door hinges with solid wood per security code -Fb fireplace space from roof -Connect gas line to fireplace -Complete electrical to fireplace -Fb gap between FlameBlock and firewall in attic above rear dining -Fasten firewall to framing per UL at kitchen wall -Support 4 ft and drain plumbing vent piping in attic toward drain -Brace firewall -Toe nail all joists to sill plates and top plates in basement with 4-8d or 3-10d -S-traps not allowed. Vent connections shall not be below trap weirs -Over notched joist below master shower. Sister another joist next to it and nail together -Reinstall blockings of joists at basement window UNIT 794: -Reinstall stud at foyer/garage wall -Fb gap between roof deck and firewall -Provide full support of girder truss at firewall end; tie down girder truss to wall -Complete electrical to front bedroom smoke alarm -Install ducting to bath fans -Tie down trusses above fireplace -Fb fireplace space from roof -Connect gas line to fireplace -Complete electrical to fireplace -Brace firewall -Toe nail all joists to sill plates and top plates in basement with 4-8d or 3-10d -S-traps not allowed. Vent connections shall not be below trap weirs -Over notched joist below master shower. Sister another joist next to it and nail together -Reinstall blockings of joists at basement window -Anchor sill plates per code **DO NOT INSULATE
Gas Service Inspection - Residential Passed 5/13/2022 5/13/2022 05/13/2022
All Rough Inspection - Residential Failed 5/31/2022 5/31/2022 05/31/2022
Misc
Corrective Action Required
05/13/2022
UNIT 790: -Connect gas line to fireplace -Fb gap between FlameBlock and firewall in attic above rear dining -Engineer to address repair of damaged truss above kitchen -Drain vent piping in attic toward drain -Brace firewall -S-traps not allowed at master shower. Vent connections shall not be below trap weirs -Reinstall blockings of joists at basement window UNIT 792: -Engineer to address repair of damaged truss above master bathroom -Connect gas line to fireplace -Fb gap between FlameBlock and firewall in attic above rear dining -Support 4 ft and drain plumbing vent piping in attic toward drain -Brace firewall -S-traps not allowed at master shower. Vent connections shall not be below trap weirs UNIT 794: -Connect gas line to fireplace -Brace firewall -S-traps not allowed at master shower. Vent connections shall not be below trap weirs **OK TO INSULATE
Rated Assembly Inspection Passed 5/31/2022 5/31/2022 05/31/2022
Misc
Resolved
05/31/2022
**See allrough inspection
All Rough Inspection - Residential Failed 6/14/2022 6/14/2022 06/14/2022
Misc
Corrective Action Required
05/31/2022
UNIT 790: -Engineer to address repair of damaged truss above kitchen **Fasten OSB sheathing per engineer letter. Fasten to all truss members. 2 rows of nails for 2x3 and 3 rows of nails for 2x4 -Drain vent piping in attic toward drain **vent piping above the kitchen must slope toward drain UNIT 792: -Engineer to address repair of damaged truss above master bathroom -Support 4 ft and drain plumbing vent piping in attic toward drain UNIT 794-OK TO ROCK
All Rough Inspection - Residential Failed 6/17/2022 6/17/2022 06/17/2022
Misc
Corrective Action Required
06/14/2022
UNIT 790: -Engineer to address repair of damaged truss above kitchen **Fasten OSB sheathing per engineer letter. Fasten to all truss members. 2 rows of nails for 2x3 and 3 rows of nails for 2x4 -Drain vent piping in attic toward drain **vent piping above the kitchen must slope toward drain UNIT 792: -Support 4 ft and drain plumbing vent piping in attic toward drain UNIT 794-OK TO ROCK
Driveway Inspection Partial 8/4/2022 8/4/2022 08/04/2022
Misc
Informational
08/04/2022
8-4-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Partial 8/5/2022 8/5/2022 08/12/2022
Misc
Informational
08/04/2022
8-4-22 AN forms are in place and aggregate is present and compacted 8-12-22 AN driveway looks good and meets Ada spec
Driveway Inspection Passed 08/12/2022
Misc
Informational
08/12/2022
8-4-22 AN forms are in place and aggregate is present and compacted 8-12-22 AN driveway looks good and meets Ada spec
Sidewalk Inspection Partial 8/5/2022 8/5/2022 08/12/2022
Misc
Informational
08/12/2022
8-4-22 AN forms are in place and aggregate is present and compacted
Sidewalk Inspection Passed 08/12/2022
Misc
Informational
08/12/2022
8-4-22 AN forms are in place and aggregate is present and compacted 8-12-22 AN sidewalk looks good and meets Ada spec
Underslab Plumbing Inspection - Residential Passed 08/24/2022
Misc
Resolved
08/24/2022
-PROVIDE CONTINUOUS GRAVEL SUPPORT
Electrical Service Inspection Passed 8/24/2022 8/24/2022 08/24/2022
Piers/Caissons Inspection - Residential Passed 12/12/2022 (1:45) 12/12/2022 12/12/2022
Misc
Informational
12/12/2022
Some of the pier holes of units 790-792 reach solid rocks, short of 36”
All Rough Inspection - Residential Failed 1/13/2023 1/13/2023 01/13/2023
Misc
Corrective Action Required
06/17/2022
UNIT 790: -Engineer to address repair of damaged truss above kitchen **Fasten OSB sheathing per engineer letter. Fasten to all truss members. 2 rows of nails for 2x3 and 3 rows of nails for 2x4 -Drain vent piping in attic toward drain **vent piping above the kitchen must slope toward drain UNIT 792: -Support 4 ft and drain plumbing vent piping in attic toward drain UNIT 794 basement finish: -Fb wall from soffit and joist space throughout **Underslab plumbing ok
All Rough Inspection - Residential Failed 1/18/2023 1/18/2023 01/18/2023
Misc
Corrective Action Required
01/13/2023
UNIT 790: -Engineer to address repair of damaged truss above kitchen **Fasten OSB sheathing per engineer letter. Fasten to all truss members. 2 rows of nails for 2x3 and 3 rows of nails for 2x4 -Drain vent piping in attic toward drain **vent piping above the kitchen must slope toward drain UNIT 792: -Support 4 ft and drain plumbing vent piping in attic toward drain UNIT 794 basement finish: -Fb wall from soffit and joist space throughout **fb closet wall from soffit **Underslab plumbing ok
All Rough Inspection - Residential Partial 1/20/2023 01/20/2023
Misc
Corrective Action Required
01/18/2023
UNIT 790: -Engineer to address repair of damaged truss above kitchen **Fasten OSB sheathing per engineer letter. Fasten to all truss members. 2 rows of nails for 2x3 and 3 rows of nails for 2x4 -Drain vent piping in attic toward drain **vent piping above the kitchen must slope toward drain UNIT 792: -Support 4 ft and drain plumbing vent piping in attic toward drain UNIT 794 basement finish-ok to rock **Underslab plumbing ok
Occupancy Inspection - Codes Residential Ready for Temp CO 2/27/2023 2/27/2023 02/27/2023
Misc
Corrective Action Required
02/27/2023
Exterior: -Final grade, sod, splash blocks Unit 794: -Complete exterior, deck, etc **TCO approved for unit 794 only
All Rough Inspection - Residential Failed 3/8/2023 3/8/2023 03/08/2023
Misc
Corrective Action Required
01/20/2023
UNIT 790: -Engineer to address repair of damaged truss above kitchen **Fasten OSB sheathing per engineer letter. Fasten to all truss members. 2 rows of nails for 2x3 and 3 rows of nails for 2x4 -Drain vent piping in attic toward drain **vent piping above the kitchen must slope toward drain
Occupancy Inspection - Codes Residential Failed 3/8/2023 3/8/2023 03/08/2023
Misc
Corrective Action Required
02/27/2023
Exterior: -Final grade, sod, splash blocks Unit 792: -Exterior not inspected at this time -Water meter is buried -Provide sewer tracer wire port at grade -Install floodlight bulbs at rear -Kitchen island receptacle not gfci-protected -Install backflow preventer at hose bibb Unit 794: -Complete exterior, deck, etc **TCO approved for unit 794 only
Occupancy Inspection - Codes Residential Ready for Temp CO 3/9/2023 03/09/2023
Misc
Corrective Action Required
03/08/2023
Exterior: -Final grade, sod, splash blocks Unit 792: -Exterior not inspected at this time -Water meter is buried -Provide sewer tracer wire port at grade -Install floodlight bulbs at rear Unit 794: -Complete exterior, deck, etc **TCO approved for unit 792 and 794 only
All Rough Inspection - Residential Failed 4/5/2023 4/5/2023 04/05/2023
Misc
Corrective Action Required
03/08/2023
UNIT 790: -Engineer to address repair of damaged truss above kitchen **Fasten OSB sheathing per engineer letter. Fasten to all truss members. 2 rows of nails for 2x3 and 3 rows of nails for 2x4 -Drain vent piping in attic toward drain **vent piping above the kitchen must slope toward drain Basement finish all-rough: -Fb top of wall space with 3/4” sheathing or other approved materials -Fb wall from soffit -Vent bathroom fan -Have engineer address cutting openings into foundation wall. Complete framing -Expose shower trap plumbing. Shower trap shall not be vented by the 3” waste stack
All Rough Inspection - Residential Partial 4/10/2023 4/10/2023 04/10/2023
Misc
Corrective Action Required
04/05/2023
UNIT 790: -Engineer to address repair of damaged truss above kitchen **Fasten OSB sheathing per engineer letter. Fasten to all truss members. 2 rows of nails for 2x3 and 3 rows of nails for 2x4
All Rough Inspection - Residential Passed 5/5/2023 5/5/2023 05/05/2023
Misc
Resolved
05/05/2023
UNIT 790: -Engineer to address repair of damaged truss above kitchen **Fasten OSB sheathing per engineer letter. Fasten to all truss members. 2 rows of nails for 2x3 and 3 rows of nails for 2x4
Occupancy Inspection - Codes Residential Ready for Temp CO 5/5/2023 05/05/2023
Misc
Corrective Action Required
03/09/2023
Exterior: -Final grade, sod, splash blocks Unit 790: -Provide engineer approval for truss repair above kitchen -Provide sewer tracer wire port at grade -Provide min 6” clearance from bottom of siding to grade -Shim gap under joists at hanger support; nail hanger; fasten the deck beam to support post with two 1/2” through bolts or equivalence Unit 792: -Exterior not inspected at this time -Provide sewer tracer wire port at grade -Install floodlight bulbs at rear Unit 794: -Complete exterior, deck, etc **TCO approved for all units
Plot Plan Inspection Passed 5/9/2023 05/09/2023
Occupancy Inspection - Codes Residential Temporary C of O 6/13/2023 06/13/2023
Misc
Corrective Action Required
05/05/2023
Unit 790: -Provide sewer tracer wire port at grade -Fasten the deck beam to support post with two 1/2” through bolts or equivalence. The posts are supposed to be notched the whole height of the deck beam and attached to the beam with two 1/2" through bolts or equivalent connector. The upper posts can be secured to the lower posts against uplift with straps Unit 792: -Provide sewer tracer wire port at grade -Fasten the deck beam to support post with two 1/2” through bolts or equivalence. The posts are supposed to be notched the whole height of the deck beam and attached to the beam with two 1/2" through bolts or equivalent connector. The upper posts can be secured to the lower posts against uplift with straps -Install floodlight bulbs at rear Unit 794: -Fasten the deck beam to support post with two 1/2” through bolts or equivalence. The posts are supposed to be notched the whole height of the deck beam and attached to the beam with two 1/2" through bolts or equivalent connector. The upper posts can be secured to the lower posts against uplift with straps **TCO approved for all units
Occupancy Inspection - Codes Residential Failed 6/27/2023 6/27/2023 06/27/2023
Misc
Corrective Action Required
06/13/2023
-Provide sewer tracer wire port at grade
Occupancy Inspection - Codes Residential Full C of O 7/21/2023 07/21/2023
Misc
Resolved
07/21/2023
-Provide sewer tracer wire port at grade
Documents & Images
Date Uploaded File Type Document Name
09/08/2021 Application Form Permit Application
09/08/2021 Application Form License Tax Form
09/10/2021 Permit Codes Residential Plan Review
09/13/2021 Approved Plans Approved Drawings
09/16/2021 Permit Codes Residential Plan Review
09/16/2021 Permit DS Building Permit
09/16/2021 Receipt Receipt for transaction:2021-007381
09/20/2021 Plot Plan Approved Plot Plan
10/19/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/04/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
11/29/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/27/2021 Approved Plans Approved Truss Layout
12/27/2021 Approved Plans Approved Truss Package
05/13/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
05/13/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
06/14/2022 I52405076_220709
06/14/2022 I52139755_220709
06/14/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
08/04/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/24/2022 Letter INSPECTION SUMMARY
08/24/2022 Letter INSPECTION SUMMARY
12/12/2022 Letter INSPECTION SUMMARY
12/29/2022 Application Form BASEMENT FINISH APPLICATION
12/30/2022 Receipt Receipt for transaction:2022-009733
01/03/2023 Approved Plans APPROVED BASEMENT DRAWING
01/13/2023 Letter INSPECTION SUMMARY
01/18/2023 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
02/27/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/27/2023 Receipt Receipt for transaction:2023-001094
03/08/2023 Letter INSPECTION SUMMARY
03/08/2023 Letter INSPECTION SUMMARY
03/09/2023 Certificate/License Codes Temporary Certificate of Occupancy
03/09/2023 Receipt Receipt for transaction:2023-001330
03/30/2023 Scope of Work SCOPE OF WORK
03/30/2023 Approved Plans 790 APPROVED BASEMENT DRAWING
03/31/2023 Receipt Receipt for transaction:2023-001809
04/05/2023 Letter INSPECTION SUMMARY
04/10/2023 Letter INSPECTION SUMMARY
05/05/2023 Letter INSPECTION SUMMARY
05/05/2023 LOT 19 ASBUILT
05/05/2023 Builder_s Basement Finish _1 Plan (version 3)
05/05/2023 790 Algonquin
05/05/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/05/2023 Receipt Receipt for transaction:2023-002851
05/08/2023 Plot Plan approved as graded plot plan
05/09/2023 Letter INSPECTION SUMMARY
06/13/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/27/2023 Letter INSPECTION SUMMARY
07/21/2023 Letter Field Certificate of Occupancy
07/21/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.