Permit Application Status

PRRES20214592


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214592
Building Permit - Residential
Certificate of Occupancy
NEW 3 OR 4 FAMILY
NEW TRIPLEX. WALKOUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK.
09/01/2021
09/17/2021
03/15/2022
02/01/2023
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
DOUG@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $2,594.55 $2,594.55 Paid 09/17/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/17/2021
8331507-Sewer Connection Fee $1,080.00 $1,080.00 Paid 09/17/2021
8331401-Water Tap Fee $10,965.00 $10,965.00 Paid 09/17/2021
8350015-Water Meter Fee $1,437.72 $1,437.72 Paid 09/17/2021
7232302-Residential License Tax Fee $3,231.36 $3,231.36 Paid 09/17/2021
8331506-EFHB Maybrook, Full $1,533.96 $1,533.96 Paid 09/17/2021
9110078-Valuation Fee for New 3 or 4 Family $147.41 $147.41 Paid 08/04/2022
$2,741.96
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/04/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/31/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/6/2021 (11:30) 10/6/2021 10/06/2021
Sewer Service Inspection - R Partial 11/2/2021 (10:45) 11/2/2021 11/02/2021
Misc
Corrective Action Required
11/02/2021
SEWER FOR UNIT 807, 809-OK
Sewer Service Inspection - R Passed 11/3/2021 (1:15) 11/3/2021 11/03/2021
Misc
Informational
11/03/2021
SEWER FOR UNIT 805, 807, 809-OK
Underslab Plumbing Inspection - Residential Passed 11/4/2021 11/4/2021 11/04/2021
Water Service Inspection - R Passed 11/5/2021 (11:30) 11/5/2021 11/05/2021
Underslab Electrical Inspection - Residential Passed 11/11/2021 11/11/2021 11/11/2021
Rated Assembly Inspection Partial 1/18/2022 1/18/2022 01/18/2022
Misc
Informational
01/18/2022
2-hr firewall not completed but looking good so far
All Rough Inspection - Residential Failed 4/15/2022 4/15/2022 04/15/2022
Misc
Corrective Action Required
04/15/2022
**REPAIR EROSION CONTROL AT WEST SIDE OF LOT 809: -Nail deck joist hangers; 2 lag screws at end of ledger board -Anchor basement sill plates within 12” of break -Brace firewall -Toe nail joist to top plates -Install basement ceiling joist hangers near stair -In garage, anchor sill plate min 7x bolt diameter away from sill plate break -Anchor garage PFH wall plates per code -Complete fireplace framing and fasten fireplace to framing -Firewall to extend to roof soffit; provide 4 ft of roof deck fire protection above master bathroom area -Provide full bearing support for girder truss at front bedroom with (4)2x4 studs all the way to foundation wall; tie down GT -Provide truss layout 807: -Nail deck joist hangers; 2 lag screws at end of ledger board **No access to unit. The east unit door was opened, the other units are locked. Builder provided no lockbox code. Attempt to contact failed 805: -Nail siding to sill plates per code -Provide 2 lag screws at end of ledger board -Fasten front ZIP board per code **No access to unit. The east unit door was opened, the other units are locked. Builder provided no lockbox code. Attempt to contact failed
Rated Assembly Inspection Failed 4/15/2022 4/15/2022 04/15/2022
Misc
Resolved
04/15/2022
Misc
Corrective Action Required
04/15/2022
**No access to all units
Gas Service Inspection - Residential Failed 4/15/2022 4/15/2022 04/15/2022
Misc
Corrective Action Required
04/15/2022
-No access to units 805&807. All pressure gauges held for min ten minutes
All Rough Inspection - Residential Failed 5/27/2022 5/27/2022 05/27/2022
Misc
Corrective Action Required
04/15/2022
**BASEMENT FINISH INSPECTED 809: -Nail deck joist hangers; 2 lag screws at end of ledger board -In garage, anchor sill plate min 7x bolt diameter away from sill plate break -Anchor garage PFH wall plates per code with 2”x2” washers -Expose underslab plumbing for inspection and terminate all abandoned plumbing -Fb basement bedroom wall from soffit **OK TO INSULATE 807: -Nail deck joist hangers; 2 lag screws at end of ledger board -Provide vertical fire blocking at kitchen firewall -Install 2”x2” washers at garage PFH walls -Protect wiring within six ft of attic access -Expose underslab plumbing for inspection and terminate all abandoned plumbing -Fb basement bedroom wall from soffit -Provide engineer address for over-notched joist below master bathroom shower -Anchor sill plate within 12” of the basement door **OK TO INSULATE 805: -Provide 2 lag screws at end of ledger board -Provide full bearing support for girder truss at front bedroom with (4)2x4 studs all the way to foundation wall -Protect wiring at front bathroom closet wall -Strap exterior wall top plates bored more than 50% in master bathroom -Install 2”x2” washers at garage PFH walls -Fb basement bedroom wall from soffit -Expose underslab plumbing for inspection and terminate all abandoned plumbing -Complete feeder to load panel **OK TO INSULATE
Rated Assembly Inspection Passed 5/27/2022 5/27/2022 05/27/2022
Misc
Resolved
05/27/2022
**No access to all units
Gas Service Inspection - Residential Passed 5/27/2022 5/27/2022 05/27/2022
Misc
Resolved
05/27/2022
-No access to units 805&807. All pressure gauges held for min ten minutes
All Rough Inspection - Residential Failed 6/7/2022 6/7/2022 06/07/2022
Misc
Corrective Action Required
05/27/2022
**BASEMENT FINISH INSPECTED 809: -Nail deck joist hangers; 2 lag screws at end of ledger board -In garage, anchor sill plate min 7x bolt diameter away from sill plate break -Anchor garage PFH wall plates per code with 2”x2” washers -Expose underslab plumbing for inspection and terminate all abandoned plumbing **OK TO INSULATE 807: -Nail deck joist hangers; 2 lag screws at end of ledger board -Protect wiring within six ft of attic access -Expose underslab plumbing for inspection and terminate all abandoned plumbing -Provide engineer address for over-notched joist below master bathroom shower **OK TO INSULATE 805: -Provide 2 lag screws at end of ledger board -Protect wiring at front bathroom closet wall -Strap exterior wall top plates bored more than 50% in master bathroom -Expose underslab plumbing for inspection and terminate all abandoned plumbing **OK TO INSULATE
All Rough Inspection - Residential Partial 6/10/2022 6/10/2022 06/10/2022
Misc
Corrective Action Required
06/07/2022
**BASEMENT FINISH INSPECTED 809: -Expose underslab plumbing for inspection and terminate all abandoned plumbing **OK TO ROCK 807: -Expose underslab plumbing for inspection and terminate all abandoned plumbing **OK TO ROCK 805: -Expose underslab plumbing for inspection and terminate all abandoned plumbing **OK TO ROCK
Driveway Inspection Partial 6/28/2022 6/28/2022 06/28/2022
Misc
Informational
06/28/2022
6-28-22 AN address 805, 807, 809 forms are in place and aggregate is present and compacted
Sidewalk Inspection Partial 6/28/2022 6/28/2022 06/28/2022
Misc
Informational
06/28/2022
6-28-22 AN address 805, 807, 809 forms are in place and aggregate is present and compacted
Driveway Inspection Passed 7/5/2022 7/5/2022 07/01/2022
Misc
Informational
06/28/2022
6-28-22 AN address 805, 807, 809 forms are in place and aggregate is present and compacted
Misc
Informational
07/01/2022
7-1-22 AN all of the driveways look good and meet Ada spec
Sidewalk Inspection Passed 7/5/2022 7/5/2022 07/01/2022
Misc
Informational
06/28/2022
6-28-22 AN address 805, 807, 809 forms are in place and aggregate is present and compacted
Misc
Informational
07/01/2022
7-1-22 AN all of the sidewalks look good and meet ADA Spec
Piers/Caissons Inspection - Residential Passed 7/6/2022 (8:45) 7/6/2022 07/06/2022
Electrical Service Inspection Passed 7/8/2022 7/8/2022 07/08/2022
All Rough Inspection - Residential Passed 08/04/2022
Misc
Resolved
08/04/2022
**BASEMENT FINISH INSPECTED 809: -Expose underslab plumbing for inspection and terminate all abandoned plumbing **OK TO ROCK 807: -Expose underslab plumbing for inspection and terminate all abandoned plumbing **OK TO ROCK 805: -Expose underslab plumbing for inspection and terminate all abandoned plumbing **OK TO ROCK
Occupancy Inspection - Codes Residential Ready for Temp CO 8/4/2022 8/4/2022 08/04/2022
Misc
Corrective Action Required
08/04/2022
*805 -Final grading and sod - obtain an irrigation permit - Gutter and down spouts - splash block - check water meter height when sod is in. - Provide permanent front door This is for TCO of 805 only. 3 plex.
Occupancy Inspection - Codes Residential Temporary C of O 08/05/2022
Misc
Corrective Action Required
08/04/2022
*805 -Final grading and sod - obtain an irrigation permit - Gutter and down spouts - splash block - check water meter height when sod is in. - Provide permanent front door This is for TCO of 805 only. 3 plex.
Plot Plan Inspection Passed 9/9/2022 09/09/2022
Occupancy Inspection - Codes Residential Failed 10/27/2022 10/27/2022 10/27/2022
Misc
Corrective Action Required
08/05/2022
UNIT 805: - Obtain an irrigation permit - check water meter height when sod is in. UNIT 809: -Obtain lawn irrigation permit and submit backflow valve test report to city -Water meter-to-lid distance exceeds city spec. (14"-18") -Provide sewer tracer wire port at grade -Install floodlight -Provide min 6 inches of clearance from siding to grade at rear of house -Provide two 1/2” through bolts (or equivalent) at each deck beam-post attachment -Complete dishwasher electrical -Provide a water hammering arrestor for dishwasher water supply -Correct ground fault condition at deck receptacle -Install cover plate for sump pump receptacle **TCO approved for unit 805 only.
Occupancy Inspection - Codes Residential Ready for Temp CO 10/31/2022 10/31/2022 10/31/2022
Misc
Corrective Action Required
10/27/2022
UNIT 805: - Obtain an irrigation permit - check water meter height when sod is in. UNIT 809: -Obtain lawn irrigation permit and submit backflow valve test report to city -Water meter-to-lid distance exceeds city spec. (14"-18") -Provide sewer tracer wire port at grade -Install floodlight -Provide min 6 inches of clearance from siding to grade at rear of house -Provide two 1/2” through bolts (or equivalent) at each deck beam-post attachment **TCO approved for unit 805 and 809 only.
Occupancy Inspection - Codes Residential Temporary C of O 12/1/2022 12/1/2022 12/01/2022
Misc
Corrective Action Required
10/31/2022
UNIT 805: - Obtain an irrigation permit. UNIT 809: -Obtain lawn irrigation permit and submit backflow valve test report to city -Water meter-to-lid distance exceeds city spec. (14"-18") **TCO approved for unit 805 and 809 only.
Occupancy Inspection - Codes Residential Failed 2/1/2023 2/1/2023 02/01/2023
Misc
Corrective Action Required
12/01/2022
UNIT 805-OK UKIT 807: -Install floodlight bulbs -Bottom support brackets for garage door track must be at 10” above floor -Remove foundation wall ties in basement UNIT 809-OK **TCO approved for units 805&809 only
Occupancy Inspection - Codes Residential Full C of O 2/1/2023 2/1/2023 02/01/2023
Misc
Resolved
02/01/2023
UNIT 805-OK UKIT 807: -Install floodlight bulbs -Bottom support brackets for garage door track must be at 10” above floor -Remove foundation wall ties in basement UNIT 809-OK **TCO approved for units 805&809 only
Documents & Images
Date Uploaded File Type Document Name
09/01/2021 Letter EXCISE TAX FORM
09/10/2021 Application Form APPLICATION
09/16/2021 Permit Codes Residential Plan Review
09/17/2021 TCR011 Triplex - Sealed Plans (September 17, 2021)
09/17/2021 Approved Plans APPROVED DRAWINGS
09/17/2021 Plot Plan APPROVED PLOT PLAN
09/17/2021 Letter LETTER
09/17/2021 Permit Codes Residential Plan Review
09/17/2021 Permit DS Building Permit
09/17/2021 Receipt Receipt for transaction:2021-007410
10/06/2021 Letter INSPECTION SUMMARY
11/02/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/04/2021 Letter INSPECTION SUMMARY
11/05/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
12/27/2021 211238A lay
12/28/2021 Drawing APPROVED DRAWINGS
12/28/2021 Approved Plans APPROVED TRUSS PACKAGE
01/18/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/19/2022 Scope of Work SCOPE OF WORK
04/21/2022 Approved Plans APPROVED BASEMENT DRAWING
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/10/2022 I52405076_220709
06/10/2022 807 Algonquin
06/10/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
08/04/2022 Letter INSPECTION SUMMARY
08/04/2022 Receipt Receipt for transaction:2022-006414
08/05/2022 Letter Codes Temporary Certificate of Occupancy
09/08/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
09/09/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter INSPECTION SUMMARY
10/31/2022 Certificate/License Codes Temporary Certificate of Occupancy
10/31/2022 Receipt Receipt for transaction:2022-008595
12/01/2022 Certificate/License Codes Temporary Certificate of Occupancy
02/01/2023 Letter INSPECTION SUMMARY
02/01/2023 Letter Field Certificate of Occupancy
02/01/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home