Permit Application Status

PRRES20214368


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214368
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINIHSED BASEMENT - COVERED DECK
08/23/2021
11/08/2021
02/20/2022
04/26/2023
Locations
Contacts
SPELLERBERG ENTERPRISES LLC, Address:613 NE VIEWPARK DR, Phone:(816) 550-5535  
Billy Spellerberg, Address:613 ne viewpark dr  
SPELLERBERGENTERPRISES@GMAIL.COM  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
NEW HEIGHTS ELECTRIC LLC, Address:P O BOX 163, Phone:(816) 625-9504  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $630.00 $630.00 Paid 11/08/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 11/08/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/08/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 11/08/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 11/08/2021
9110078-Valuation Fee New Single Family $1,565.10 $1,565.10 Paid 11/08/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/11/2021 (11:00) 11/11/2021 11/11/2021
Underslab Plumbing Inspection - Residential Failed 12/7/2021 12/7/2021 12/07/2021
Misc
Corrective Action Required
12/07/2021
Provide proper venting for basement bathroom see code section P3108.2.1 Horizontal wet vent
Underslab Plumbing Inspection - Residential Passed 12/8/2021 12/8/2021 12/08/2021
Misc
Resolved
12/08/2021
Provide proper venting for basement bathroom see code section P3108.2.1 Horizontal wet vent
Sewer Service Inspection - R Passed 5/9/2022 5/9/2022 05/09/2022
Water Service Inspection - R Passed 5/10/2022 (1:00) 5/10/2022 05/10/2022
All Rough Inspection - Residential Failed 7/12/2022 7/12/2022 07/12/2022
Misc
Corrective Action Required
07/12/2022
Complete exhaust vent first floor bathroom Attach csst gas line at fire place Unable to inspect cspf nail pattern on second floor bedroom near entry Nail 3 stud pack together north west bedroom Fire block top plate penetration hallway at front bedroom Fire block penetration top plate laundry Complete ductwork all bathroom fans Fire block top plate penetrations at master bedroom Project wiring within 6’ if attic access Open section of patio roof for inspection
Electrical Service Inspection Passed 7/12/2022 7/12/2022 07/12/2022
Gas Service Inspection - Residential Failed 7/12/2022 7/12/2022 07/12/2022
Misc
Corrective Action Required
07/12/2022
No pressure gauge found
All Rough Inspection - Residential Passed 7/22/2022 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
Complete exhaust vent first floor bathroom Attach csst gas line at fire place Unable to inspect cspf nail pattern on second floor bedroom near entry Nail 3 stud pack together north west bedroom Fire block top plate penetration hallway at front bedroom Fire block penetration top plate laundry Complete ductwork all bathroom fans Fire block top plate penetrations at master bedroom Project wiring within 6’ if attic access Open section of patio roof for inspection
Gas Service Inspection - Residential Passed 7/25/2022 7/25/2022 07/25/2022
Misc
Resolved
07/25/2022
No pressure gauge found
Piers/Caissons Inspection - Residential Failed 8/29/2022 (11:15) 8/29/2022 08/29/2022
Misc
Corrective Action Required
08/29/2022
inspected 3 24" piers -address north most pier no to depth -address piers not in located to plans.
Driveway Inspection Partial 9/1/2022 9/1/2022 09/01/2022
Misc
Informational
09/01/2022
9-1-22 RH. Driveway was formed up and aggregate was placed and compacted.
Driveway Inspection Passed 9/8/2022 9/8/2022 09/08/2022
Misc
Informational
09/01/2022
9-1-22 RH. Driveway was formed up and aggregate was placed and compacted. 9-8-22 RH. Driveway meets LS Specification.
Driveway Inspection Passed 9/8/2022 09/08/2022
Misc
Informational
09/08/2022
9-1-22 RH. Driveway was formed up and aggregate was placed and compacted. 9-8-22 RH. Driveway meets LS Specification.
Sidewalk Inspection Partial 3/6/2023 3/6/2023 03/06/2023
Misc
Informational
03/06/2023
3-6-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour.
Sidewalk Inspection Partial 3/6/2023 3/6/2023 03/07/2023
Misc
Informational
03/07/2023
3-6-23 RH. Sidewalk is formed up and aggreagate is placed and compacted. Approved to pour.
Sidewalk Inspection Partial 3/14/2023 3/14/2023 03/14/2023
Misc
Informational
03/06/2023
3-6-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 3-14-23 RH. Sidewalk was not completely poured and one panel is left.
Sidewalk Inspection Partial 3/21/2023 3/21/2023 03/21/2023
Misc
Informational
03/14/2023
3-6-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 3-14-23 RH. Sidewalk was not completely poured and one panel is left. 3-21-23 RH. Sidewalk was not completely poured and one panel is left.
Sidewalk Inspection Partial 3/28/2023 3/28/2023 03/28/2023
Misc
Informational
03/21/2023
3-6-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 3-14-23 RH. Sidewalk was not completely poured and one panel is left. 3-21-23 RH. Sidewalk was not completely poured and one panel is left. 3-28-23 RH. Sidewalk not completed yet.
Sidewalk Inspection Passed 4/4/2023 4/4/2023 04/04/2023
Misc
Informational
03/28/2023
3-6-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 3-14-23 RH. Sidewalk was not completely poured and one panel is left. 3-21-23 RH. Sidewalk was not completely poured and one panel is left. 3-28-23 RH. Sidewalk not completed yet. 4-4-23 RH. Sidewalk meets LS and ADA specification.
Piers/Caissons Inspection - Residential Passed 4/20/2023 04/20/2023
Misc
Resolved
04/20/2023
inspected 3 24" piers -address north most pier no to depth -address piers not in located to plans.
Plot Plan Inspection Passed 4/20/2023 04/20/2023
Erosion Control Inspection Residential Passed 4/20/2023 04/20/2023
Occupancy Inspection - Codes Residential Failed 4/20/2023 4/20/2023 04/20/2023
Misc
Corrective Action Required
04/20/2023
-lable all non GFCI outlets in unfinished spaces -garage entry door to be self closing and latching -master bath receptacle will not reset -faceplate for outlet box in furnace room
Occupancy Inspection - Codes Residential Failed 4/24/2023 4/24/2023 04/24/2023
Misc
Corrective Action Required
04/20/2023
-lable all non GFCI outlets in unfinished spaces -master bath receptacle will not reset
Occupancy Inspection - Codes Residential Full C of O 4/26/2023 4/26/2023 04/26/2023
Misc
Resolved
04/26/2023
-lable all non GFCI outlets in unfinished spaces -master bath receptacle will not reset
Documents & Images
Date Uploaded File Type Document Name
08/24/2021 3106 SW BLUE RIBBON - PERMIT APP EXCISE FORM
08/24/2021 Permit Codes Residential Plan Review
08/25/2021 Approved Plans APPROVED PLANS
08/25/2021 Plot Plan APPROVED PLOT PLAN
08/25/2021 Permit Codes Residential Plan Review
11/08/2021 Permit DS Building Permit
11/08/2021 Receipt Receipt for transaction:2021-008553
11/11/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter INSPECTION SUMMARY
04/28/2022 Letter Codes 140 Day Letter
04/28/2022 Letter Codes 140 Day Letter
04/28/2022 Letter Codes 140 Day Letter
05/09/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/12/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
07/25/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
09/01/2022 Spellerberg SVF 65 Porch revisions
09/01/2022 Approved Plans Approved Revised Drawings
09/01/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
01/26/2023 Letter Codes 140 Day Letter
03/06/2023 Letter INSPECTION SUMMARY
03/07/2023 Letter INSPECTION SUMMARY
03/14/2023 Letter INSPECTION SUMMARY
03/21/2023 Letter INSPECTION SUMMARY
03/28/2023 Letter INSPECTION SUMMARY
04/04/2023 65A as graded plot plan
04/04/2023 Letter INSPECTION SUMMARY
04/12/2023 Plot Plan approved as graded plot plan
04/20/2023 Letter INSPECTION SUMMARY
04/20/2023 Letter INSPECTION SUMMARY
04/20/2023 Letter INSPECTION SUMMARY
04/20/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter INSPECTION SUMMARY
04/26/2023 Letter Field Certificate of Occupancy
04/26/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home