Summary
PRRES20214193
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK TILE ROOF
08/11/2021
08/19/2021
02/08/2022
04/29/2022
Locations
Contacts
Classic Design Homes LLC, Address:909 SE Scarlet Ct  
CHOYCE LLC, Address:PO BOX 847  
Chad Butler, Address:909 SE Scarlet Ct, Phone:(816) 699-7727  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
Aesir Electric LLC, Address:27202 E 283RD ST, Phone:(816) 288-4309  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
CHADBUTLER@CASSICDESIGNKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331506-EFHB Maybrook, Full $596.54 $596.54 Paid 08/19/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 08/19/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/19/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/19/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/19/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/19/2021
9110078-Valuation Fee New Single Family $1,340.65 $1,340.65 Paid 08/19/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 9/20/2021 09/20/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/20/2021
EROSION CONTROL REQUIRED ALONG THE STREET AND AT LOT ENTRANCE. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Footing Inspection - Residential Failed 9/20/2021 09/20/2021
Misc
Corrective Action Required
09/20/2021
**DENIED DUE TO EROSION CONTROL DEFICIENCY
Footing Inspection - Residential Passed 9/24/2021 (8:00) 9/24/2021 09/24/2021
Misc
Resolved
09/24/2021
**DENIED DUE TO EROSION CONTROL DEFICIENCY
Underslab Plumbing Inspection - Residential Passed 10/22/2021 10/22/2021 10/22/2021
Miscellaneous Inspection Passed 11/2/2021 11/02/2021
Informational
11/02/2021
-Garage structural slab-OK
Sewer Service Inspection - R Passed 11/18/2021 (10:15) 11/18/2021 11/18/2021
Water Service Inspection - R Passed 11/22/2021 (9:45) 11/22/2021 11/22/2021
Driveway Inspection Partial 12/27/2021 12/28/2021
Misc
Informational
12/28/2021
12-27-21 AN Forms are in place and aggregate is present and compacted.
Electrical Service Inspection Failed 12/28/2021 12/28/2021 12/28/2021
Misc
Corrective Action Required
12/28/2021
-Provide a listed grounding clamp to rebar. The acorn grounding clamp is only listed for grounding connection of copper conductor to grounding rod. Hint: Notice the contact of dissimilar metals (copper GEC to iron)when use the acorn grounding clamp to rebar
Electrical Service Inspection Passed 12/29/2021 12/29/2021 12/29/2021
Misc
Resolved
12/29/2021
All Rough Inspection - Residential Failed 1/5/2022 1/5/2022 01/05/2022
Misc
Corrective Action Required
01/05/2022
-More nailing into garage PFH h-frame -Provide anchor within 12” of garage sill plate break -Nail corner studs per code with 16d@12” oc or equivalent nailing -Cannot supply attic light from dedicated garage 20 amp receptacle circuit -Fb all wall plate penetration at mud/pantry; at master bathroom sink wall -Hanger above rear dining wall corner; hangers outside master bedroom -Security code: fill in gap behind exterior door hinges and strike plate side with solid wood -Brace ends of roof support beams against rotation -Fb fireplace space with 3/4” sheathing and at gaps -Provide 3-stud support for 14” lvl at fireplace/bedroom wall -Bath fan flexible ducts cannot exceed 14 ft. Need to start switching to 4” flexible or hard duct per IRC1505 -Strap top plates lapped less than 24” at master closet -Provide 18” lvl beam above kitchen -Provide 5-stud support for kitchen lvl beam -Provide floor receptacle at guardrail -Provide min 6’8” headroom clearance above stair -Toe nail all joists to sill plates and top plates per code -Anchor basement sill plates per code -Provide venting for front bathroom tub trap -Fb basement wall vertically at ten ft or less interval; fb with 3/4” sheathing or other approved material; Fb gaps, Fb space at basement bathroom shower -Provide double 2x12 header at basement slide door **DO NOT INSULATE
Gas Service Inspection - Residential Passed 1/5/2022 01/05/2022
Driveway Inspection Passed 1/3/2022 1/3/2022 01/07/2022
Misc
Informational
12/28/2021
12-27-21 AN Forms are in place and aggregate is present and compacted.
Misc
Informational
01/07/2022
1-7-22 AN Driveway looks good and meets Ada spec
All Rough Inspection - Residential Failed 1/10/2022 1/10/2022 01/10/2022
Misc
Corrective Action Required
01/05/2022
-Nail corner studs per code with 16d@12” oc or equivalent nailing -Bath fan flexible ducts cannot exceed 14 ft. Need to start switching to 4” flexible or hard duct per IRC1505 -Strap top plates lapped less than 24” at master closet -Fb basement wall vertically at ten ft or less interval; fb with 3/4” sheathing or other approved material; Fb gaps, Fb space at basement bathroom shower **OK TO INSULATE
All Rough Inspection - Residential Partial 1/12/2022 1/12/2022 01/12/2022
Misc
Corrective Action Required
01/10/2022
-Bath fan flexible ducts cannot exceed 14 ft. Need to start switching to 4” flexible or hard duct per IRC1505 **Bathroom fan in basement **OK TO ROCK
All Rough Inspection - Residential Passed 1/19/2022 1/19/2022 01/19/2022
Misc
Resolved
01/19/2022
Sidewalk Inspection Partial 3/30/2022 3/30/2022 03/30/2022
Misc
Informational
03/30/2022
3-30-22 AN forms are in place and aggregate is present and compacted
Sidewalk Inspection Failed 4/8/2022 4/8/2022 04/08/2022
Misc
Informational
03/30/2022
3-30-22 AN forms are in place and aggregate is present and compacted
Miscellaneous Correction
Corrective Action Required
04/08/2022
4-8-22 AN 4 pics attached. 1 - The ADA truncated dome needs to go the whole width of the panel with a max of 1in gap on each side also smooth tie bars at the curb and isolation joint at the back of the Ada ramp. 2- there are 2 storm boxes and they need expansion joints between the sidewalk and storm box lid. 3 - one of the panels have been broken by equipment driving over it.
Plot Plan Inspection Passed 4/26/2022 04/26/2022
Erosion Control Inspection Residential Passed 04/26/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/26/2022
EROSION CONTROL REQUIRED ALONG THE STREET AND AT LOT ENTRANCE. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Sidewalk Inspection Passed 4/18/2022 4/18/2022 04/29/2022
Misc
Informational
04/08/2022
3-30-22 AN forms are in place and aggregate is present and compacted
Miscellaneous Correction
Corrective Action Required
04/08/2022
4-8-22 AN 4 pics attached. 1 - The ADA truncated dome needs to go the whole width of the panel with a max of 1in gap on each side also smooth tie bars at the curb and isolation joint at the back of the Ada ramp. 2- there are 2 storm boxes and they need expansion joints between the sidewalk and storm box lid. 3 - one of the panels have been broken by equipment driving over it.
Misc
Informational
04/29/2022
4-29-22 AN all repairs have been made and look good
Occupancy Inspection - Codes Residential Full C of O 4/29/2022 4/29/2022 04/29/2022
Documents & Images
Date Uploaded File Type Document Name
08/11/2021 LOT 42 FINAL
08/12/2021 LS
08/12/2021 LEE'S SUMMIT
08/12/2021 Permit Codes Residential Plan Review
08/16/2021 Approved Plans Approved Drawings
08/16/2021 Plot Plan Approved Plot Plan
08/17/2021 Permit Codes Residential Plan Review
08/19/2021 Permit DS Building Permit
08/19/2021 Receipt Receipt for transaction: 2021-006667
09/24/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/24/2021 Villas at Chapel Ridge, Lot 42
10/22/2021 Letter INSPECTION SUMMARY
11/02/2021 Letter INSPECTION SUMMARY
11/18/2021 Letter INSPECTION SUMMARY
11/22/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
12/29/2021 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/06/2022 Heritage - Structural Letter (January 6, 2022)
01/07/2022 Letter INSPECTION SUMMARY
01/07/2022 Letter INSPECTION SUMMARY
01/10/2022 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
04/08/2022 Sidewalk 1
04/08/2022 Sidewalk 2_Sidewalk 2
04/08/2022 Sidewalk 3
04/08/2022 Sidewalk 4
04/08/2022 Letter INSPECTION SUMMARY
04/25/2022 Plot Plan Approved As Graded Plot Plan
04/26/2022 Letter INSPECTION SUMMARY
04/26/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter INSPECTION SUMMARY
04/29/2022 Letter Codes Final Certificate of Occupancy
04/29/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home