Permit Application Status

PRRES20213832


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213832
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERD DECK
07/23/2021
07/26/2021
03/23/2023
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
HIGGINBOTHAM.BRIAN@YAHOO.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE ELECTRICAL CONSTRUCTION, Address:3710 ROBINSON PIKE RD, Phone:(816) 761-0200  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,137.90 $1,137.90 Paid 07/26/2021
Right of Way Permit Fee $80.00 $80.00 Paid 07/26/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/26/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 07/26/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 07/26/2021
Water Meter Fee $479.24 $479.24 Paid 07/26/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 03/22/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/2/2021 (11:30) 9/2/2021 09/02/2021
Underslab Plumbing Inspection - Residential Passed 9/24/2021 9/24/2021 09/24/2021
Sewer Service Inspection - R Passed 9/28/2021 09/28/2021
Water Service Inspection - R Passed 10/1/2021 10/01/2021
Erosion Control Inspection Residential Failed 10/1/2021 10/1/2021 10/01/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/01/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Piers/Caissons Inspection - Residential Passed 1/5/2022 1/5/2022 01/05/2022
Misc
Informational
01/05/2022
APPROVED PER CHAD M STREETER 1/3/22
Suspended Slab Inspection Passed 1/5/2022 1/5/2022 01/05/2022
Misc
Informational
01/05/2022
APPROVED PER CHAD M STREETER 1/3/22
Gas Service Inspection - Residential Not Ready 1/6/2022 1/6/2022 01/06/2022
Misc
Corrective Action Required
01/06/2022
-NOT READY FOR INSPECTION -COMPLETE FIREPLACE INSTALL -GAS LINE BOND REQUIRED
Electrical Service Inspection Failed 1/26/2022 1/26/2022 01/26/2022
Misc
Corrective Action Required
01/26/2022
COLOR CODE GEC AT TERMINATION POINTS
Gas Service Inspection - Residential Failed 1/26/2022 1/26/2022 01/26/2022
Misc
Corrective Action Required
01/06/2022
-GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Failed 1/26/2022 1/26/2022 01/26/2022
Misc
Corrective Action Required
01/26/2022
-anchor bolts should be in middle third of plate at garage -bocca protection plate DWV garage wall, plate must protect DWV at plate and2” below the top plate -seal bottom plate penetration SE cable at pantry -security blocking at master bed exterior door -protection plate at bottom plate pex master closet -fireblock between studs along soffit line at master shower -provide structural straps at all interior load bearing walls and all exterior walls bored 50% or more, strap should be 16 ga, 1 1/2” wide and extend 6” passed both side of opening -CS-PF bracing design per plans at breakfast windows see detail plans/IRC R602.10.6.4 -have engineer address rafters landing on block above ceiling joists throughout, rafter/ceiling joist/top plate nailing per code -complete electrical at basement suspended slab -fireblock at soffit line basement bath, fb annual space at DWV and seal penetration -secure all DWV 2” or less at mid point -see basement bath, basement wet bar -3” oc grid nailing pattern sheathing to header at garage portal PFH, see plans IRC R602.10.6.2
Electrical Service Inspection Passed 3/1/2022 3/1/2022 03/01/2022
Misc
Resolved
03/01/2022
Gas Service Inspection - Residential Failed 3/1/2022 3/1/2022 03/01/2022
Misc
Corrective Action Required
01/26/2022
-GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR TEST 3/1/22 no pressure
All Rough Inspection - Residential Failed 3/1/2022 3/1/2022 03/01/2022
Misc
Corrective Action Required
01/26/2022
-provide structural straps at all interior load bearing walls and all exterior walls bored 50% or more, strap should be 16 ga, 1 1/2” wide and extend 6” passed both side of opening -CS-PF bracing design per plans at breakfast windows see detail plans/IRC R602.10.6.4 -have engineer address rafters landing on block above ceiling joists throughout, rafter/ceiling joist/top plate nailing per code -complete electrical at basement suspended slab
Gas Service Inspection - Residential Failed 3/4/2022 3/4/2022 03/04/2022
Misc
Corrective Action Required
03/01/2022
-GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR TEST 3/1/22 no pressure 3/4/22 NO PRESSURE
All Rough Inspection - Residential Failed 3/3/2022 3/4/2022 03/04/2022
Misc
Corrective Action Required
03/01/2022
-complete electrical at basement suspended slab OKAY TO INSULATE
Gas Service Inspection - Residential Passed 3/8/2022 3/8/2022 03/08/2022
Misc
Resolved
03/08/2022
-GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR TEST 3/1/22 no pressure 3/4/22 NO PRESSURE
Driveway Inspection Partial 5/18/2022 5/18/2022 05/18/2022
Misc
Informational
05/18/2022
On 5.18.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Sidewalk Inspection Partial 5/18/2022 5/18/2022 05/18/2022
Misc
Informational
05/18/2022
On 5.18.2022 i performed a sidewalk inspection and pass the subgrade to pour concrete.
All Rough Inspection - Residential Passed 07/01/2022
Misc
Resolved
07/01/2022
Erosion Control Inspection Residential Passed 07/01/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/01/2022
Plot Plan Inspection Passed 07/01/2022
Occupancy Inspection - Codes Residential Temporary C of O 7/1/2022 07/01/2022
Miscellaneous Correction
Corrective Action Required
07/01/2022
driveway inspection pending Sidewalk inspection pending Obtain an irrigation permit and submit back flow certification Pay all fees Splash blocks Provide gutters and down spouts Provide permanent address numbers of contrasting colors
Driveway Inspection Passed 11/2/2022 11/2/2022 11/02/2022
Misc
Informational
05/18/2022
On 5.18.2022 I performed a driveway inspection and pass the subgrade to pour concrete 11-2-22 RH. Meets LS and ADA specification.
Sidewalk Inspection Passed 11/2/2022 11/2/2022 11/02/2022
Misc
Informational
05/18/2022
On 5.18.2022 i performed a sidewalk inspection and pass the subgrade to pour concrete. 11-2-22 RH. Meets LS and ADA specification.
Occupancy Inspection - Codes Residential Full C of O 3/23/2023 3/23/2023 03/23/2023
Miscellaneous Correction
Resolved
03/23/2023
Splash blocks
Documents & Images
Date Uploaded File Type Document Name
07/23/2021 Application Form Permit Application
07/23/2021 Application Form License Tax Form
07/26/2021 Permit Codes Residential Plan Review
07/26/2021 Permit DS Building Permit
07/26/2021 Receipt Receipt for transaction:2021-005924
09/02/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
01/04/2022 1812 SW Sage Canyon Rd_SUS GAR SLAB-STOOP & DECK PIER INSP_2022-01-03
01/05/2022 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/06/2022 Letter INSPECTION SUMMARY
01/21/2022 Approved Plans Approved Drawings
01/24/2022 Plot Plan Approved Plot Plan
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Engineer Report/Study Engineer Letter
03/04/2022 Letter INSPECTION SUMMARY
03/04/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter Codes Temporary Certificate of Occupancy
11/02/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter INSPECTION SUMMARY
03/22/2023 Letter Codes 140 Day Letter
03/22/2023 Receipt Receipt for transaction:2023-001614
03/23/2023 Letter Codes Residential Plan Review
03/23/2023 Letter Field Certificate of Occupancy
03/23/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home