Permit Application Status

PRRES20213402


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213402
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW RESIDENTIAL CONSTRUCTION. UNFINISHED BASEMENT - UNCOVERED PATIO
07/01/2021
07/07/2021
10/20/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOE@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/07/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/07/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 07/07/2021
9110078-Valuation Fee New Single Family $988.55 $988.55 Paid 07/07/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 07/07/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 07/07/2021
8331504-EFHB Middle Big Creek, Full $468.72 $468.72 Paid 10/22/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/19/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/6/2021 10/6/2021 10/06/2021
Misc
Informational
10/06/2021
9/29/2021 David ainsworth
Underslab Plumbing Inspection - Residential Failed 10/21/2021 10/21/2021 10/21/2021
Misc
Corrective Action Required
10/21/2021
Inspection denied, backfill required for access to view plumbing.
Erosion Control Inspection Residential Failed 10/21/2021 10/21/2021 10/21/2021
Misc
Corrective Action Required
10/21/2021
-fix silt fence -clean up street
Underslab Plumbing Inspection - Residential Passed 11/3/2021 11/3/2021 11/03/2021
Misc
Resolved
11/03/2021
Misc
Resolved
11/03/2021
Erosion Control Inspection Residential Failed 11/3/2021 11/03/2021
Misc
Corrective Action Required
10/21/2021
-fix silt fence -clean up street
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
11/03/2021
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Sewer Service Inspection - R Passed 11/11/2021 (1:00) 11/11/2021 11/11/2021
Water Service Inspection - R Passed 11/16/2021 11/16/2021
Electrical Service Inspection Failed 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/20/2022
NO CITY STAMPED PLANS ON SITE
Gas Service Inspection - Residential Failed 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/20/2022
NO CITY STAMPED PLANS ON SITE
All Rough Inspection - Residential Not Ready 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/20/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Gas Service Inspection - Residential Passed 5/5/2022 5/5/2022 05/05/2022
Misc
Resolved
05/05/2022
NO CITY STAMPED PLANS ON SITE
Electrical Service Inspection Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
04/20/2022
E3607.5 SYSTEM GROUNDING. An unspliced main bonding jumper shall be used to connect the equipment grounding conductor(s) and the service-disconnect enclosure to the grounded conductor of the system within the enclosure for each service disconnect. -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
All Rough Inspection - Residential Failed 5/5/2022 5/5/2022 05/05/2022
Misc
Corrective Action Required
04/20/2022
-provide structural straps at top plates bored 50% or more all exterior walls and interior load bearing walls -secure all vertical DWV 2” or less at mid point -have engineer address overbored floor joists above kitchen/bathroom 1st floor for DWV -have engineer address floor joist above garage entry several bores for DWV and pex less than 2” apart -have engineer address (5) floor joists overbored for DWV and bores less than 2” from end of joist throughout kitchen -fireblock HVAC chase 2nd floor -secure NM laundry receptacle per code -provide flashing boots all roof penetrations -provide studs shoes at exterior studs bored for DWV master bath vanity -have engineer clarify C5 triple girder truss load bearing point above 2nd floor hall, wall is shown at non load bearing in plans -address C5 girder truss 2nd floor, only (1) ply matches detail with chord -UFER at basement stairs must be accessible at finish -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
Erosion Control Inspection Residential Partial 05/05/2022
Misc
Resolved
05/05/2022
-fix silt fence -clean up street
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
05/05/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Electrical Service Inspection Passed 6/7/2022 6/7/2022 06/07/2022
Misc
Resolved
06/07/2022
All Rough Inspection - Residential Failed 6/7/2022 6/7/2022 06/07/2022
Misc
Corrective Action Required
05/05/2022
-fireblock HVAC chase 2nd floor ( see penetration at floor around ducts) -nail off stud shoes complete per manufacturer, not screws
Driveway Inspection Partial 6/7/2022 6/7/2022 06/07/2022
Driveway Inspection Partial 6/7/2022 06/07/2022
Misc
Informational
06/07/2022
Driveway approach is formed and ready to pour.
All Rough Inspection - Residential Passed 6/8/2022 6/8/2022 06/08/2022
Misc
Resolved
06/08/2022
Driveway Inspection Passed 6/9/2022 06/09/2022
Misc
Informational
06/07/2022
Driveway approach is formed and ready to pour.
Misc
Informational
06/09/2022
Driveway approach appears to be compliant.
Sidewalk Inspection Partial 6/9/2022 6/9/2022 06/09/2022
Misc
Informational
06/09/2022
On 6.9.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete. City Standards were met.
Sidewalk Inspection Passed 7/20/2022 7/20/2022 07/20/2022
Misc
Informational
06/09/2022
On 6.9.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete. City Standards were met. 7.20.2022 Sidewalk appears to be in compliance
Erosion Control Inspection Residential Passed 10/17/2022 10/17/2022 10/17/2022
Plot Plan Inspection Passed 10/17/2022 10/17/2022 10/17/2022
Occupancy Inspection - Codes Residential Failed 10/17/2022 10/17/2022 10/17/2022
Misc
Corrective Action Required
10/17/2022
-resolve outstanding inspection fee -complete plumbing basement left of water heater, open 3" line
Occupancy Inspection - Codes Residential Full C of O 10/20/2022 10/20/2022 10/20/2022
Misc
Resolved
10/20/2022
Documents & Images
Date Uploaded File Type Document Name
07/01/2021 OS #35 - PERMIT APP
07/07/2021 Plot Plan Approved Plot Plan
07/07/2021 Permit Codes Residential Plan Review
07/07/2021 Permit DS Building Permit
07/07/2021 Receipt Receipt for transaction:2021-005446
09/03/2021 Approved Plans Approved Drawings
09/03/2021 Approved Plans Approved Truss Package
09/03/2021 Approved Plans Approved Truss Layout
10/05/2021 M L Crose 2113 SW Rutherford Dr LSMO Osage Lot 35 Clayton P 2021-3402 3rd Party Footing Inspection Report 9-29-21
10/14/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
11/03/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
11/16/2021 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
05/05/2022 Letter INSPECTION SUMMARY
06/07/2022 35 Osage Field Issue Letter #2
06/07/2022 35 Osage Field Issue Letter
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/19/2022 Receipt Receipt for transaction:2022-008360
10/20/2022 Letter Field Certificate of Occupancy
10/20/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home