Summary
PRRES20213165
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
06/21/2021
06/22/2021
12/19/2021
07/03/2023
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
HIGGINBOTHAM.BRIAN@YAHOO.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,407.63 $1,407.63 Paid 06/22/2021
Right of Way Permit Fee $80.00 $80.00 Paid 06/22/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/22/2021
8331504-EFHB Middle Big Creek, Full $636.12 $636.12 Paid 06/22/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 06/22/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 06/22/2021
Water Meter Fee $455.54 $455.54 Paid 06/22/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 07/20/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Not Ready 7/12/2021 (11:30) 7/12/2021 07/12/2021
Misc
Corrective Action Required
07/12/2021
INSPECTION DENIED , EROSION CONTROL REQUIRED NO EROSION CONTROL ON LOT AT TIME OF INSPECTION 7/12/21 12:30PM
Erosion Control Inspection Residential Failed 7/12/2021 7/12/2021 07/12/2021
Misc
Corrective Action Required
07/12/2021
INSPECTION DENIED , EROSION CONTROL REQUIRED NO EROSION CONTROL ON LOT AT TIME OF INSPECTION 7/12/21 12:30PM
Footing Inspection - Residential Passed 7/20/2021 (11:30) 7/20/2021 07/20/2021
Misc
Resolved
07/20/2021
Erosion Control Inspection Residential Partial 7/20/2021 7/20/2021 07/20/2021
Misc
Resolved
07/20/2021
Underslab Plumbing Inspection - Residential Passed 8/18/2021 8/18/2021 08/18/2021
Sewer Service Inspection - R Passed 8/24/2021 (2:15) 8/24/2021 08/24/2021
Water Service Inspection - R Passed 8/27/2021 (1:00) 8/27/2021 08/27/2021
All Rough Inspection - Residential Failed 4/7/2022 4/7/2022 04/07/2022
Miscellaneous Correction
Corrective Action Required
04/07/2022
- protect se cable - complete plumbing at joist space at double garage - Complete plumbing at single bay garage - Support ridge on deck roof - Provide egress window basement - Anchor bolt required at steel column basement - Security blocking at garage man door -Strap top plates sw bed room SW corner , and at vault break in top plates. -no rafter to ceiling joist connection rear wall of sw bed room. -support lower end of valley rafter over stairs. Cantilevered built up 2x4’s and 3/4” plywood is not a support. -center rear bedroom rear west corner, tie in top plates per code. -support ceiling joist in hallway over closet. No header installed. -no ridge support over master bath from ,front closet to the rear. -provide rafter ties in the lower 1/3 over master closet. -missing boca plate front bathroom vent. -support rafters per code over hallway, rafters are spliced and supported by flat perlin. -perlin flat against bottom of rafter serves no support. Perlin supports shall be vertical. -support hip rafter where meets ridge over center bedroom/ hall. -provide rafter ties over front bedroom and entryway. -tie in top plates at front entry tall wall and front bed. 2x6wall meets 2x4wall.
Electrical Service Inspection Passed 4/7/2022 4/7/2022 04/07/2022
Gas Service Inspection - Residential Failed 4/7/2022 4/7/2022 04/07/2022
Misc
Corrective Action Required
04/07/2022
Gas line requires bonding
All Rough Inspection - Residential Failed 4/21/2022 4/21/2022 04/21/2022
Miscellaneous Correction
Corrective Action Required
04/07/2022
- Support ridge on deck roof -Strap top plates sw bed room SW corner , and at vault break in top plates. -no rafter to ceiling joist connection rear wall of sw bed room. -center rear bedroom rear west corner, tie in top plates per code. -support rafters per code over hallway, rafters are spliced and supported by flat perlin. -perlin flat against bottom of rafter serves no support. Perlin supports shall be vertical. -provide rafter ties over front bedroom and entryway.
All Rough Inspection - Residential Passed 5/2/2022 5/2/2022 05/02/2022
Miscellaneous Correction
Resolved
05/02/2022
Erosion Control Inspection Residential Partial 5/2/2022 5/2/2022 05/02/2022
Gas Service Inspection - Residential Passed 5/9/2022 5/9/2022 05/09/2022
Misc
Resolved
05/09/2022
Gas line requires bonding
Erosion Control Inspection Residential Partial 5/9/2022 5/9/2022 05/09/2022
Erosion Control Inspection Residential Failed 6/2/2022 06/02/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/02/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. MAINTAIN EROSION CONTROL ON LOT
Miscellaneous Inspection Failed 6/29/2023 06/29/2023
Misc
Informational
06/29/2023
Miscellaneous inspection to extend permit only and contractor will be able to schedule inspections
Occupancy Inspection - Codes Residential Failed 6/30/2023 6/30/2023 06/30/2023
Miscellaneous Correction
Corrective Action Required
06/30/2023
- All vertical boards in the garage above the over head doors need to be sealed at the ceiling - One joist hanger in the basement storage room is missing nails - East basement window well needs a emergency exit ladder installed - West basement window well needs more gravel added so the total bottom rung is no more then 18 inches from the base - Sump pump electrical outlet needs to state it is non GFGI protected - Master bathroom is missing an electrical outlet for the smaller vanity sink - Exterior ground level slopes towards the house by the basement window on the east side of the home - Exterior yard grading on the east side of home slopes towards the house foundation and needs to be at no less than a two percent slope away from the foundation. - Submit an as is graded plot plan - A irrigation permit is required for the system already installed - Driveway final was never completed
Piers/Caissons Inspection - Residential Failed 6/30/2023 06/30/2023
Miscellaneous Correction
Corrective Action Required
06/30/2023
Provided pier inspection for back deck
Driveway Inspection Passed 6/2/2022 06/30/2023
Misc
Informational
06/02/2022
On 6.2.2022 I performed a driveway inspection and pass the subgrade to pour concrete 6-30-23 BR Driveway is concreted to LS specification
Driveway Inspection Passed 6/30/2023 6/30/2023 06/30/2023
Misc
Informational
06/02/2022
On 6.2.2022 I performed a driveway inspection and pass the subgrade to pour concrete 6-30-23 BR Driveway is concreted to LS specification
Piers/Caissons Inspection - Residential Passed 6/30/2023 06/30/2023
Miscellaneous Correction
Resolved
06/30/2023
Provided pier inspection for back deck
Miscellaneous Correction
Informational
06/30/2023
Deck piers sign off by a third party
Occupancy Inspection - Codes Residential Full C of O 7/3/2023 07/03/2023
Miscellaneous Correction
Resolved
07/03/2023
- All vertical boards in the garage above the over head doors need to be sealed at the ceiling - One joist hanger in the basement storage room is missing nails - East basement window well needs a emergency exit ladder installed - West basement window well needs more gravel added so the total bottom rung is no more then 18 inches from the base - Sump pump electrical outlet needs to state it is non GFGI protected - Master bathroom is missing an electrical outlet for the smaller vanity sink - Exterior ground level slopes towards the house by the basement window on the east side of the home - Exterior yard grading on the east side of home slopes towards the house foundation and needs to be at no less than a two percent slope away from the foundation. - Submit an as is graded plot plan - A irrigation permit is required for the system already installed - Driveway final was never completed
Erosion Control Inspection Residential Passed 7/3/2023 07/18/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/02/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. MAINTAIN EROSION CONTROL ON LOT
Plot Plan Inspection Passed 7/3/2023 07/18/2023
Documents & Images
Date Uploaded File Type Document Name
06/21/2021 Application Form Permit Application
06/21/2021 Application Form License Tax Form
06/21/2021 Approved Plans Approved Drawings
06/22/2021 Permit Codes Residential Plan Review
06/22/2021 Plot Plan Approved Plot Plan
06/22/2021 Permit Codes Residential Plan Review
06/22/2021 Permit DS Building Permit
06/22/2021 Receipt Receipt for transaction:2021-004778
07/12/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/20/2021 Receipt Receipt for transaction:2021-005760
07/20/2021 Letter INSPECTION SUMMARY
07/20/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
04/21/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
11/29/2022 Letter Codes 140 Day Letter
01/17/2023 Letter Codes 180 Day Letter
06/28/2023 Application Form EXTENSION FORM
06/28/2023 Engineer Report/Study 1829 SW Sage Canyon Dr_SUS FRONT STOOP SLAB DECK PIER INSP_2021-10-06
06/29/2023 Letter INSPECTION SUMMARY
06/30/2023 Letter INSPECTION SUMMARY
06/30/2023 Letter INSPECTION SUMMARY
06/30/2023 Letter INSPECTION SUMMARY
06/30/2023 Letter INSPECTION SUMMARY
06/30/2023 Letter INSPECTION SUMMARY
06/30/2023 LOT 158 ASBUILT
06/30/2023 Letter INSPECTION SUMMARY
06/30/2023 Plot Plan approved as graded plot plan
07/03/2023 Letter Codes Final Certificate of Occupancy
07/03/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home