Permit Application Status

PRRES20213109


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213109
Building Permit - Residential
Certificate of Occupancy
NEW 3 OR 4 FAMILY
NEW 4-PLEX - UNFINISHED BASEMENT - UNCOVERED PATIO
06/17/2021
06/21/2021
12/14/2021
10/06/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $3,141.17 $3,141.17 Paid 06/21/2021
8331507-Sewer Connection Fee $1,560.00 $1,560.00 Paid 06/21/2021
8331401-Water Tap Fee $14,324.00 $14,324.00 Paid 06/21/2021
8350015-Water Meter Fee $1,822.16 $1,822.16 Paid 06/21/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/21/2021
7232302-Residential Excise Tax Fee $4,308.48 $4,308.48 Paid 06/21/2021
8331504-EFHB Middle Big Creek, Full $1,740.96 $1,740.96 Paid 10/22/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $150.00 $150.00 Paid 07/11/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/11/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/25/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/30/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 10/05/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/2/2021 9/2/2021 09/02/2021
Misc
Informational
09/02/2021
APPROVED PER DAVID P AINSWORTH 8/25/21
Sewer Service Inspection - R Partial 9/21/2021 (9:30) 9/21/2021 09/21/2021
Misc
Informational
09/21/2021
3723, 3725 OK
Sewer Service Inspection - R Partial 9/22/2021 (10:30) 9/22/2021 09/22/2021
Misc
Informational
09/21/2021
3723, 3725, 3721 OK
Sewer Service Inspection - R Passed 9/23/2021 (2:30) 9/23/2021 09/23/2021
Misc
Informational
09/22/2021
3723, 3725, 3721, 3727 OK
Underslab Plumbing Inspection - Residential Passed 9/23/2021 9/23/2021 09/23/2021
Misc
Informational
09/23/2021
.3721,3721,3725,3727 OK
Water Service Inspection - R Partial 9/24/2021 9/24/2021 09/24/2021
Misc
Informational
09/24/2021
3723,3725,3727 OK
Water Service Inspection - R Passed 9/27/2021 (9:15) 9/27/2021 09/27/2021
Misc
Informational
09/24/2021
3723,3725,3727,3721 OK
Gas Service Inspection - Residential Failed 2/28/2022 02/28/2022
Misc
Corrective Action Required
02/28/2022
Not ready
All Rough Inspection - Residential Failed 2/28/2022 2/28/2022 02/28/2022
Misc
Corrective Action Required
02/28/2022
**PROVIDE MIN 3/4” GRAVEL AT DRIVEWAY UNIT 3721: -Install trim and flashing above slide door -Nail garage PFH wall sheathing to studs, sill plates, and header per code; install tension straps -Anchor garage sill plate within 12” of break -Install wall bracing straps per plan -Strap interior bearing wall top plates where bored more than 50% (at garage&half bath wall) -Install front entry door per security code -Joists above foyer bored more than allowed 1/3 joist depth -Install stud shoe at exterior wall stud where bored more than 40% (at SE cable) -Toe nail joists to top plates per code -Fb fire separation wall space vertically at ten ft or less interval -Fire caulk fire wall penetrations by SE cables -Fb duct chase from roof -Strap top plates lapped less than 24” at 2nd floor rear wall -Protect SE cables at top and bottom wall plates -Repair damaged fire rock at front bedroom -Connect fire rock to framing at bedroom 3 -Install breakaway alum clips at 10 ft oc for the top 23 ft of fire wall; install breakaway alum clips at 5 ft oc for fire wall below the top 23 ft; In attic, secure fire rock at max 10 ft -Support A truss to B2 girder above front bedroom -Provide information for lok screw rating. The B2 girder has 1169 lbs and 844 lbs uplift at ends -Nail together B2 girder per truss detail -Fb space at master bathroom shower from roof -Provide bearing to basement sill plate for cut joist below door from garage into dwelling; below entry door -Toe nail basement ceiling joists to sill plates per code -Provide double 2x10 header above basement window -Install hangers above furnace -Complete gas piping **DO NOT INSULATE UNIT 3723: -Not ready UNIT 3725: -Nail garage PFH wall sheathing to studs, sill plates, and header per code; install tension straps -Anchor garage sill plate within 12” of break -Strap interior bearing wall top plates where bored more than 50% (at garage&half bath wall) -Joists above foyer bored more than allowed 1/3 joist depth -Toe nail joists to top plates per code -Fb fire separation wall space vertically at ten ft or less interval -Strap wall top plates lapped less than 24” at bedroom 2 -Fire caulk fire wall penetrations by SE cables -Provide 4 ft of roof deck fire protection from the firewall -Connect fire rock to framing at bedroom 3 -Install breakaway alum clips at 10 ft oc for the top 23 ft of fire wall; install breakaway alum clips at 5 ft oc for fire wall below the top 23 ft; In attic, secure fire rock at max 10 ft -Complete wall framing at 2nd fl hallway bathroom receptacle -Secure wiring within 8” of receptacle box at master bedroom (right of window on firewall) -Tie down B4 girder to wall -Fb space at master bathroom shower from roof -Strap sill plate to window header -Install hangers above furnace -Complete gas piping **OK TO INSULATE UNIT 3727: -Install trim and flashing above slide door -Nail garage PFH wall sheathing to studs, sill plates, and header per code; install tension straps -Anchor garage sill plate within 12” of break -Fasten fire rock to blockings per UL design -Strap interior bearing wall top plates where bored more than 50% (at garage&half bath wall) -Joists above foyer bored more than allowed 1/3 joist depth -Toe nail joists to top plates per code -Fb fire separation wall space vertically at ten ft or less interval -Fire caulk attic fire wall penetrations by SE cables -Protect 3” DVW at closet/duct chase bottom wall plate -Connect fire rock to framing at bedroom 3 -Install breakaway alum clips at 10 ft oc for the top 23 ft of fire wall; install breakaway alum clips at 5 ft oc for fire wall below the top 23 ft; In attic, secure fire rock at max 10 ft -Tie down B2 girder truss -Fb space at master bathroom shower from roof -Strap sill plate to window header -Install hangers above furnace -Complete gas piping **OK TO INSULATE
Electrical Service Inspection Failed 2/28/2022 02/28/2022
Misc
Corrective Action Required
02/28/2022
-Install #4 copper jumper from the bus bar where the ufer GEC is connected to to the service grounded bus bar (the lug is on the other side) -Ampacity adjustment for SE cables installed in attic space is required. Refer to NEC 334/338, 310.15(B)(7) FYI: you do not have to install 4 separate GEC to ufer rebar. Only one min #4 copper GEC to ufer rebar is required.
All Rough Inspection - Residential Failed 3/8/2022 3/8/2022 03/08/2022
Misc
Corrective Action Required
02/28/2022
**3/8/21- NOT READY FOR INSPECTION, BEGAN AT UNIT 3721 NUMEROUS DEFICIENCIES REMAIN, CORRECT ALL DEFICIENCIES BEFORE RESCHEDULING INSPECTION **PROVIDE MIN 3/4” GRAVEL AT DRIVEWAY <---GET THIS ADDRESSED BEFORE RESCHEDULING INSPECTION UNIT 3721: -Install trim and flashing above slide door -Nail garage PFH wall sheathing to studs, sill plates, and header per code; install tension straps -Anchor garage sill plate within 12” of break -Install wall bracing straps per plan -Strap interior bearing wall top plates where bored more than 50% (at garage&half bath wall) -Install front entry door per security code -Joists above foyer bored more than allowed 1/3 joist depth -Install stud shoe at exterior wall stud where bored more than 40% (at SE cable) -Toe nail joists to top plates per code -Fb fire separation wall space vertically at ten ft or less interval -Fire caulk fire wall penetrations by SE cables. Refer to A7.1 for detail -Fb duct chase from roof -Strap top plates lapped less than 24” at 2nd floor rear wall -Protect SE cables at top and bottom wall plates -Repair damaged fire rock at front bedroom -Connect fire rock to framing at bedroom 3 -Install breakaway alum clips at 10 ft oc for the top 23 ft of fire wall; install breakaway alum clips at 5 ft oc for fire wall below the top 23 ft; In attic, secure fire rock at max 10 ft -Support A truss to B2 girder above front bedroom -Provide information for lok screw rating. The B2 girder has 1169 lbs and 844 lbs uplift at ends -Nail together B2 girder per truss detail -Fb space at master bathroom shower from roof -Provide bearing to basement sill plate for cut joist below door from garage into dwelling; below entry door -Toe nail basement ceiling joists to sill plates per code -Provide double 2x10 header above basement window -Install hangers above furnace -Complete gas piping **DO NOT INSULATE UNIT 3723: -Not ready UNIT 3725: -Nail garage PFH wall sheathing to studs, sill plates, and header per code; install tension straps -Anchor garage sill plate within 12” of break -Strap interior bearing wall top plates where bored more than 50% (at garage&half bath wall) -Joists above foyer bored more than allowed 1/3 joist depth -Toe nail joists to top plates per code -Fb fire separation wall space vertically at ten ft or less interval -Strap wall top plates lapped less than 24” at bedroom 2 -Fire caulk fire wall penetrations by SE cables. Refer to A7.1 for detail -Provide 4 ft of roof deck fire protection from the firewall -Connect fire rock to framing at bedroom 3 -Install breakaway alum clips at 10 ft oc for the top 23 ft of fire wall; install breakaway alum clips at 5 ft oc for fire wall below the top 23 ft; In attic, secure fire rock at max 10 ft -Complete wall framing at 2nd fl hallway bathroom receptacle -Secure wiring within 8” of receptacle box at master bedroom (right of window on firewall) -Tie down B4 girder to wall -Fb space at master bathroom shower from roof -Strap sill plate to window header -Install hangers above furnace -Complete gas piping **OK TO INSULATE UNIT 3727: -Install trim and flashing above slide door -Nail garage PFH wall sheathing to studs, sill plates, and header per code; install tension straps -Anchor garage sill plate within 12” of break -Fasten fire rock to blockings per UL design -Strap interior bearing wall top plates where bored more than 50% (at garage&half bath wall) -Joists above foyer bored more than allowed 1/3 joist depth -Toe nail joists to top plates per code -Fb fire separation wall space vertically at ten ft or less interval -Fire caulk attic fire wall penetrations by SE cables. Refer to A7.1 for detail -Protect 3” DVW at closet/duct chase bottom wall plate -Connect fire rock to framing at bedroom 3 -Install breakaway alum clips at 10 ft oc for the top 23 ft of fire wall; install breakaway alum clips at 5 ft oc for fire wall below the top 23 ft; In attic, secure fire rock at max 10 ft -Tie down B2 girder truss -Fb space at master bathroom shower from roof -Strap sill plate to window header -Install hangers above furnace -Complete gas piping
Gas Service Inspection - Residential Failed 3/22/2022 3/22/2022 03/22/2022
Misc
Corrective Action Required
02/28/2022
GAS LINE BONDS REQUIRED
Electrical Service Inspection Failed 3/22/2022 3/22/2022 03/22/2022
Misc
Corrective Action Required
02/28/2022
-Install #4 copper jumper from the bus bar where the ufer GEC is connected to to the service grounded bus bar (the lug is on the other side) -Ampacity adjustment for SE cables installed in attic space is required. Refer to NEC 334/338, 310.15(B)(7) FYI: you do not have to install 4 separate GEC to ufer rebar. Only one min #4 copper GEC to ufer rebar is required.
All Rough Inspection - Residential Failed 3/22/2022 3/22/2022 03/22/2022
Misc
Corrective Action Required
03/08/2022
UNIT 3721: -Joists above foyer bored more than allowed 1/3 joist depth -Fire caulk fire wall penetrations by SE cables. Refer to A7.1 for detail -fb at top plate at fire rock wall duct chase 2nd floor bed -seal top plate penetration 2nd floor bed -Repair damaged fire rock at front bedroom **OK TO INSULATE UNIT 3723: -Tighten anchor bolts garage -Fb fire separation wall space vertically at ten ft or less interval -secure all DWV 2” or less at mid point -fireblock HVAC through floor penetrations at great room chase -Joists above foyer bored more than allowed 1/3 joist depth -security blocking at front door hinge side -(2) 2x4 trimmer studs at garage entry per plans -dbl 2x10 floor joists at garage per plans -Toe nail joists to top plates per code -Fire caulk fire wall penetrations by SE cables. Refer to A7.1 for detail -repair damaged fire rock 2nd floor -Strap interior bearing wall top plates where bored more than 50% - see 2nd floor -fb at top plate at fire rock wall duct chase 2nd floor bed -provide (4) 2x4 stud pack at girder truss bearing ends per plans -provide bocca protection plate at bottom plate HVAC chase 2nd floor bed closet -have ladder on site to be able to inspect fire rated plywood and fire rock 2nd floor -all truss lateral bracing per plans -secure SCH40 steel column to floor at basement -provide anchor bolts at bottom plate basement egress window **DO NOT INSULATE** UNIT 3725: -Joists above foyer bored more than allowed 1/3 joist depth -Fb fire separation wall space vertically at ten ft or less interval -Fire caulk fire wall penetrations by SE cables. Refer to A7.1 for detail **OK TO INSULATE UNIT 3727: -Nail garage PFH wall sheathing to studs, sill plates, and header per code; install tension straps -Joists above foyer bored more than allowed 1/3 joist depth -Fire caulk attic fire wall penetrations by SE cables. Refer to A7.1 for detail -Protect 3” DVW at closet/duct chase bottom wall plate **OK TO INSULATE
Rated Assembly Inspection Failed 3/22/2022 3/22/2022 03/22/2022
Misc
Corrective Action Required
03/22/2022
UNIT 3721: -Fire caulk fire wall penetrations by SE cables. Refer to A7.1 for detail -fb at top plate at fire rock wall duct chase 2nd floor bed -Repair damaged fire rock at front bedroom UNIT 3723: -Fb fire separation wall space vertically at ten ft or less interval -Fire caulk fire wall penetrations by SE cables. Refer to A7.1 for detail -repair damaged fire rock 2nd floor -have ladder on site to be able to inspect fire rated plywood and fire rock 2nd floor UNIT 3725: -Fb fire separation wall space vertically at ten ft or less interval -Fire caulk fire wall penetrations by SE cables. Refer to A7.1 for detail UNIT 3727: -Fire caulk attic fire wall penetrations by SE cables. Refer to A7.1 for detail
Gas Service Inspection - Residential Failed 3/29/2022 3/29/2022 03/29/2022
Misc
Corrective Action Required
03/22/2022
GAS LINE BONDS REQUIRED, schedule with all rough inspection
Electrical Service Inspection Passed 3/30/2022 3/30/2022 03/30/2022
Misc
Resolved
03/30/2022
-Install #4 copper jumper from the bus bar where the ufer GEC is connected to to the service grounded bus bar (the lug is on the other side) -Ampacity adjustment for SE cables installed in attic space is required. Refer to NEC 334/338, 310.15(B)(7) FYI: you do not have to install 4 separate GEC to ufer rebar. Only one min #4 copper GEC to ufer rebar is required.
All Rough Inspection - Residential Failed 3/30/2022 3/30/2022 03/30/2022
Misc
Corrective Action Required
03/22/2022
UNIT 3721: -Seal old plate penetrations for SE cable at 1st and 2nd floor -Add stud shoes at exterior studs bored for SE cable -Repair damaged fire rock at front bedroom, firecaulk -have engineer address floor joists bored for SE feeder cable ls less than 2” from end of joist UNIT 3723: -seal old SE cable penetrations in top and bottom plates 1st/2nd floor -repair damaged fire rock 2nd floor -C channel guide required at fire rock to roof deck see A7.0 plans, large gaps between rock to deck -Strap interior bearing wall top plates where bored more than 50% - see 2nd floor -fb at top plate at fire rock wall duct chase 2nd floor bed -have engineer address floor joists bored for SE feeder cable ls less than 2” from end of joist UNIT 3725: -seal old SE cable penetrations in top and bottom plates 1st/2nd floor -repair damaged fire rock -C channel guide required at fire rock to roof deck, see page A7.0 -4’ rated plywood attached at underside of deck, fire rated plywood face nailed to plywood -have engineer address floor joists bored for SE feeder cable ls less than 2” from end of joist UNIT 3727: -seal bottom plate penetration at 2nd and 1st floor for old SE cable penetration -Fire caulk attic fire wall penetrations by SE cables. Refer to A7.1 for detail -repair damaged fire rock
Rated Assembly Inspection Failed 3/30/2022 3/30/2022 03/30/2022
Misc
Corrective Action Required
03/22/2022
UNIT 3721: -Repair damaged fire rock at front bedroom, firecaulk UNIT 3723: -repair damaged fire rock 2nd floor -C channel guide required at fire rock to roof deck see A7.0 plans, large gaps between rock to deck -fb at top plate at fire rock wall duct chase 2nd floor bed UNIT 3725: -repair damaged fire rock -C channel guide required at fire rock to roof deck, see page A7.0 -4’ rated plywood attached at underside of deck, fire rated plywood face nailed to plywood UNIT 3727: -Fire caulk attic fire wall penetrations by SE cables. Refer to A7.1 for detail -repair damaged fire rock
Erosion Control Inspection Residential Failed 4/1/2022 04/01/2022
Misc
Corrective Action Required
04/01/2022
ADDRESS EROSION CONTROL AT FRONT OF LOT
All Rough Inspection - Residential Failed 4/1/2022 4/1/2022 04/01/2022
Misc
Corrective Action Required
03/30/2022
UNIT 3721: OK UNIT 3723: -repair damaged fire rock 2nd floor UNIT 3725: -repair damaged fire rock -C channel guide required at fire rock to roof deck, see page A7.0, remove blocking to allow for inspection UNIT 3727: OK **OK TO INSULATE**
Gas Service Inspection - Residential Passed 4/1/2022 4/1/2022 04/01/2022
Misc
Resolved
04/01/2022
GAS LINE BONDS REQUIRED, schedule with all rough inspection
Rated Assembly Inspection Failed 4/1/2022 4/1/2022 04/01/2022
Misc
Corrective Action Required
03/30/2022
UNIT 3721: OK UNIT 3723: -repair damaged fire rock 2nd floor UNIT 3725: -repair damaged fire rock -C channel guide required at fire rock to roof deck, see page A7.0, remove blocking to allow for inspection UNIT 3727: OK
All Rough Inspection - Residential Passed 4/5/2022 4/5/2022 04/05/2022
Misc
Resolved
04/05/2022
Rated Assembly Inspection Passed 4/5/2022 4/5/2022 04/05/2022
Misc
Resolved
04/05/2022
Driveway Inspection Passed 4/1/2022 04/28/2022
Misc
Informational
04/01/2022
On Friday 4.1.2022 i performed a driveway inspection and pass the subgrade to pour concrete for addresses 3721 SW Walsh Dr and 3727 SW Walsh Dr. This is a 4 plex house that has two more driveways to be inspected.
Sidewalk Inspection Partial 5/9/2022 5/9/2022 05/09/2022
Misc
Informational
05/09/2022
This is a fourplex unit. On 5.9.2022 I performed a sidewalk inspection for units 3723 and 3725 SW Walsh Drive and pass the subgrade to pour concrete.
Driveway Inspection Partial 5/9/2022 5/9/2022 05/09/2022
Misc
Informational
05/09/2022
This is a fourplex unit. On 5.9.2022 I performed a driveway inspection for units 3723 and 3725 SW Walsh Drive and pass the subgrade to pour concrete.
Occupancy Inspection - Codes Residential Failed 7/1/2022 7/1/2022 07/01/2022
Misc
Corrective Action Required
07/01/2022
-resolve outstanding inspection fees -final grade and sod -final sidewalk inspection required, contact development services to schedule -splash blocks all downspout and sump pump locations, min 36” discharge from foundation UNIT 3727: -provide gravel base at water meter pit -attic ventilation at garage -install cover plates all switches and outlets -dishwasher outlet requires GFCI protection -smoke/co detector required on 1st floor -2 car garage bay requires (2) 20 amp outlets accessible each side of bay -mud and tape at garage door brackets garage ceiling , open to framing -max 3/8” variance between stair rises garage, patio stairs -smoke/co detector required outside bedroom hall 2nd floor -install all smokes 2nd floor -provide support basement stair handrail -AFCI protection all breaker locations per code IRC E3902.16, NEC 210.12(A) -label all breaker locations at service panel, make sure all legible -Cap future plumbing vent basement -cap main clean out at basement -max AC overcurrent protection listed 25 amps **NO INSPECTION PERFORMED 3725, 3723, 3721 UNITS
Sidewalk Inspection Passed 6/17/2022 6/17/2022 07/07/2022
Misc
Informational
05/09/2022
This is a fourplex unit. On 5.9.2022 I performed a sidewalk inspection for units 3723 and 3725 SW Walsh Drive and pass the subgrade to pour concrete. On 6.17.2022 I performed a sidewalk inspection for the side sidewalk (faces Osage Drive) and pass the sub-grade to pour concrete. On 7.7.2022 The sidewalks appear to be in compliance
Driveway Inspection Passed 7/7/2022 7/8/2022 07/08/2022
Misc
Informational
05/09/2022
This is a fourplex unit. On 5.9.2022 I performed a driveway inspection for units 3723 and 3725 SW Walsh Drive and pass the subgrade to pour concrete.
Occupancy Inspection - Codes Residential Ready for Temp CO 7/8/2022 7/8/2022 07/08/2022
Misc
Corrective Action Required
07/01/2022
i am approving a TCO, fees need to be paid and the $50 TCO fee. this TCO will extend for 6 months because it is a modle as per Jason Huit.MARK HARDING 07/08/2022 12:12 PM the other units need to be 100% complete on the interior prrior to move in. -resolve outstanding inspection fees -final grade and sod -final sidewalk inspection required, contact --still pening. development services to schedule -splash blocks all downspout and sump pump locations, min 36” discharge from foundation UNIT 3727: -attic ventilation at garage **NO INSPECTION PERFORMED 3725, 3723, 3721 UNITS
Occupancy Inspection - Codes Residential Failed 7/11/2022 7/11/2022 07/11/2022
Misc
Corrective Action Required
07/11/2022
i am approving a TCO, fees need to be paid and the $50 TCO fee. this TCO will extend for 6 months because it is a modle as per Jason Huit.MARK HARDING 07/08/2022 12:12 PM the other units need to be 100% complete on the interior prrior to move in. -resolve outstanding inspection fees -final grade and sod -final sidewalk inspection required, contact --still pening. development services to schedule -splash blocks all downspout and sump pump locations, min 36” discharge from foundation UNIT 3727: -attic ventilation at garage **NO INSPECTION PERFORMED 3725, 3723, 3721 UNITS
Misc
Corrective Action Required
07/11/2022
3721 sw Walsh drive •Provide anti tipping device for oven •Address steps at patio entry over 7 3/4” and not within 3/8” variance on flight •Uncover smoke detectors in master bedroom •Label non gfci outlet in basement •Protect electrical panel from water line above •Sump discharge minimum of 36” from foundation •Splash blocks •Seal top of A/C disconnect •Seal top of meter can •Roof vents at garage not installed •Final grading and sod 3723 sw Walsh drive •steps at entry not within the 3/8” variance •Dishwasher outlet not gfci protected •Address steps to patio, one over 7 3/4” and not within the 3/8” variance for total flight •Attach electrical whip at water heater •Add gravel to Egress window well •Sump discharge minimum of 36” from foundation •Splash blocks •Roof vents at garage not installed •Seal top of A/C disconnect •Final grading and sod 3725 sw Walsh drive •Sump discharge minimum of 36” from foundation •Splash blocks •Address Steps to patio not within the 3/8” variance on entire flight •Provide lock outs electrical panel •Add gravel to Egress window well •Seal top of A/C disconnect •Roof vents at garage not installed •Final grading and sod 3727 sw Walsh •Roof vents at garage not installed •Sump discharge minimum of 36” from foundation •Splash blocks •Add gravel to Egress window well •Seal top of A/C disconnect •Outlet cover missing middle bedroom •Attach water heater electrical whip •Protect electrical panel from water line above •Anchor steel columns in basement •Final grading and sod
Erosion Control Inspection Residential Passed 07/15/2022
Misc
Resolved
07/15/2022
Plot Plan Inspection Passed 07/15/2022
Occupancy Inspection - Codes Residential Failed 7/15/2022 7/15/2022 07/15/2022
Misc
Corrective Action Required
07/11/2022
i am approving a TCO, fees need to be paid and the $50 TCO fee. this TCO will extend for 6 months because it is a modle as per Jason Huit.MARK HARDING 07/08/2022 12:12 PM the other units need to be 100% complete on the interior prrior to move in. -final sidewalk inspection required, contact --still pening. development services to schedule - UNIT 3727: **NO INSPECTION PERFORMED 3725, 3723, 3721 UNITS
Occupancy Inspection - Codes Residential Failed 7/19/2022 7/19/2022 07/19/2022
Misc
Corrective Action Required
07/15/2022
**PER BUILDER UNIT 3721 WILL BE MODEL HOME AND NOT 3727 -Provide permanent address labels at meter cans and disconnect -splash blocks, min 36" discharge from foundation UNIT 3727: ok for TCO UNIT 3721: -provide rated enclosure for UFER at garage wall -AFCI protection all breaker locations per code -label all breaker locations, no general or vague locations -shorten AC electrical whip above grade, currently covered with sod UNIT 3723: -max 3/8” variance between stair rises basement -AFCI protection all breaker locations per code -label all breaker locations, no general or vague locations -shorten AC electrical whip above grade, currently covered with sod UNIT 3725: -provide hammer arrestors at dishwasher -provide rated enclosure for UFER at garage wall -max 3/8” variance between stair rises - see garage, 2nd floor stairs -AFCI protection all breaker per code -label all breaker locations, no general or vague locations -provide outlet for sprinkler system, currently running on outlet with extension cord
Occupancy Inspection - Codes Residential Ready for Temp CO 7/25/2022 7/25/2022 07/25/2022
Misc
Corrective Action Required
07/19/2022
**PER BUILDER UNIT 3721 WILL BE MODEL HOME AND NOT 3727 -Provide permanent address labels at meter cans and disconnect -splash blocks, min 36" discharge from foundation UNIT 3727: ok for TCO UNIT 3721: ok for TCO, this unit is to be used as model UNIT 3723: ok for TCO UNIT 3725: ok for TCO
Occupancy Inspection - Codes Residential Temporary C of O 07/25/2022
Misc
Corrective Action Required
07/25/2022
**PER BUILDER UNIT 3721 WILL BE MODEL HOME AND NOT 3727 -Provide permanent address labels at meter cans and disconnect -splash blocks, min 36" discharge from foundation UNIT 3727: ok for TCO UNIT 3721: ok for TCO, this unit is to be used as model UNIT 3723: ok for TCO UNIT 3725: ok for TCO
Occupancy Inspection - Codes Residential Ready for Temp CO 8/29/2022 08/29/2022
Misc
Corrective Action Required
07/25/2022
**PER BUILDER UNIT 3721 WILL BE MODEL HOME AND NOT 3727 -Provide permanent address labels at meter cans and disconnect -splash blocks, min 36" discharge from foundation UNIT 3727: ok for TCO UNIT 3721: ok for TCO, this unit is to be used as model UNIT 3723: ok for TCO UNIT 3725: ok for TCO
Occupancy Inspection - Codes Residential Temporary C of O 08/30/2022
Misc
Corrective Action Required
08/29/2022
**PER BUILDER UNIT 3721 WILL BE MODEL HOME AND NOT 3727 -Provide permanent address labels at meter cans and disconnect -splash blocks, min 36" discharge from foundation UNIT 3727: ok for TCO UNIT 3721: ok for TCO, this unit is to be used as model UNIT 3723: ok for TCO UNIT 3725: ok for TCO
Occupancy Inspection - Codes Residential Not Ready 10/5/2022 10/5/2022 10/05/2022
Misc
Corrective Action Required
08/30/2022
-splash blocks, min 36" discharge from foundation, see sump pump discharge lines -resolve inspection fee UNIT 3727: ok for TCO UNIT 3721: ok for TCO, this unit is to be used as model UNIT 3723: ok for TCO UNIT 3725: ok for TCO
Occupancy Inspection - Codes Residential Full C of O 10/6/2022 10/6/2022 10/06/2022
Misc
Resolved
10/06/2022
-splash blocks, min 36" discharge from foundation, see sump pump discharge lines -resolve inspection fee UNIT 3727: ok for TCO UNIT 3721: ok for TCO, this unit is to be used as model UNIT 3723: ok for TCO UNIT 3725: ok for TCO
Documents & Images
Date Uploaded File Type Document Name
06/17/2021 OS #8 - PERMIT APP
06/17/2021 2765833 RF SEAL 04232021
06/17/2021 Permit Codes Residential Plan Review
06/21/2021 Plot Plan Approved Plot Plan
06/21/2021 Approved Plans Approved Truss Package
06/21/2021 Permit Codes Residential Plan Review
06/21/2021 Permit DS Building Permit
06/21/2021 Receipt Receipt for transaction:2021-004739
07/01/2021 Plot Plan Approved Revised Plot Plan
08/23/2021 Approved Plans APPROVED TRUSS LAYOUT
09/01/2021 M L Crose 3721 3723 3725 3727 SW Walsh Dr LSMO Osage Lot 8 Clayton P 2021-3109 3rd Party Footing Inspection Report 8-25-21
09/02/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
01/27/2022 Approved Plans Approved Drawings
02/28/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/22/2022 8 osage letter
03/22/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
03/31/2022 8 osage letter - SE cable joist
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter INSPECTION SUMMARY
07/08/2022 Letter INSPECTION SUMMARY
07/11/2022 Receipt Receipt for transaction:2022-005659
07/11/2022 Letter Codes Temporary Certificate of Occupancy
07/11/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/25/2022 Receipt Receipt for transaction:2022-006051
07/25/2022 Letter Codes Temporary Certificate of Occupancy
08/26/2022 Extension Request Form OS8B,C,D
08/29/2022 Email RE_ Permanent address labels for meter cans
08/29/2022 Letter Extension Request Form OS8B,C,D
08/30/2022 Receipt Receipt for transaction:2022-007128
08/30/2022 Letter Codes Temporary Certificate of Occupancy
10/05/2022 Letter INSPECTION SUMMARY
10/05/2022 Receipt Receipt for transaction:2022-008056
10/06/2022 Letter Field Certificate of Occupancy
10/06/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home