Permit Application Status

PRRES20212998


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212998
Building Permit - Residential
Certificate of Occupancy
MONTICELLO HOMES LLC
NEW SINGLE FAMILY
NEW HOUSE - SUSPENDED SLAB - ENGINEERED FLOOR SYSTEM - TILE ROOF - FINISHED AND UNFINISHED BASEMENT - COVERED DECK THE EXTERIOR BUILDING MATERIALS FOR THIS HOUSE IS GOING THROUGH THE PDP PROCESS AND STAFF SUPPORTS THE PROPOSED MATERIALS. WE WILL RELEASE THIS PERMIT BASED ON THAT PDP BEING APPROVED STOP WORK ORDER generated on 07/26/2021 12:00 AM by username 'Khanh Nguyen'. STOP WORK ORDER removed on 08/04/2021 12:00 AM by username 'Khanh Nguyen'.
06/11/2021
07/09/2021
12/18/2021
07/03/2023
Locations
Contacts
GRANTS CUSTOM HOMES, Address:1001 CEDAR ST, Phone:(816) 739-1444  
MONTICELLO HOMES LLC, Address:623 NE LONE HILL DR  
Scott Grant, Address:1001 Cedar Street, Phone:(816) 739-1444  
ARICA@GRANTSCUSTOMHOMES.COM  
LANCASTER BROTHERS HEATING/COOLING, Address:PO BOX 1202, Phone:(913) 851-3399  
Porter's Electrical Co., LLC, Address:114 Veterans PKWY  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331506-EFHB Maybrook, Full $511.32 $511.32 Paid 07/09/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 07/09/2021
Right of Way Permit Fee $80.00 $80.00 Paid 07/09/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/09/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 07/09/2021
Water Meter Fee $455.54 $455.54 Paid 07/09/2021
Valuation Fee New Single Family $973.92 $973.92 Paid 07/09/2021
Temporary Occupancy Fee $50.00 $50.00 Paid 11/18/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed - Stop Work 7/26/2021 07/26/2021
Misc
Corrective Action Required
07/26/2021
7/26/21-STOPPED BY TO CHECK ON THE FOOTING THAT WAS APPROVED BY DAVID AINTSWORTH ENGINEERING. THE FOOTING WAS POURED BUT THERE IS NO EROSION CONTROL INSTALLED. STOP-WORK ORDER IS ISSUED
Erosion Control Inspection Residential Failed - Stop Work 7/26/2021 07/26/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/26/2021
EROSION CONTROL REQUIRED. STOP-WORK ORDER ISSUED
Footing Inspection - Residential Passed 08/04/2021
Misc
Resolved
08/04/2021
7/26/21-STOPPED BY TO CHECK ON THE FOOTING THAT WAS APPROVED BY DAVID AINTSWORTH ENGINEERING. THE FOOTING WAS POURED BUT THERE IS NO EROSION CONTROL INSTALLED. STOP-WORK ORDER IS ISSUED
Erosion Control Inspection Residential Failed 8/4/2021 8/4/2021 08/04/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/26/2021
EROSION CONTROL REQUIRED ALONG THE FRONT STREET CURB
Underslab Plumbing Inspection - Residential Passed 8/12/2021 8/12/2021 08/12/2021
Super Structure Inspection Passed 10/13/2021 10/13/2021 10/13/2021
Informational
10/13/2021
THIS IS A SLAB. WE DO NOT INSPECT THE SLAB, UNLESS IT IS STRUCTURAL SLAB AND IS REQUESTED BY THE BUILDER.
Suspended Slab Inspection Passed 11/9/2021 (8:45) 11/9/2021 11/09/2021
Piers/Caissons Inspection - Residential Passed 1/31/2022 (11:15) 1/31/2022 01/31/2022
Electrical Service Inspection Passed 4/12/2022 4/12/2022 04/12/2022
All Rough Inspection - Residential Failed 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/12/2022
** PROVIDE EROSION CONTROL ALONG PROPERTY LINE AND TO PROTECT REAR STORM INLEY -Anchor garage sill plates per code -Nail rafters to ceiling joists -Support end of 2x10 ridge above stair wall outside master bedroom door -Install electric fireplace -Provide fall protection for master bedroom windows -Provide roof ventilation per code -Protect wiring at bottom wall plate adjacent to slide door -Nail double ceiling joist hanger above oven -Brace ends of roof lvl beam from rotation -Provide (3)2x4 support for 16” lvl beam at great room exterior wall -Brace interior walls per plan -Fb basement wall space from ceiling space; provide 10 ft or less vertical fire blocking at front bedroom exterior wall -Provide full bearing for lvl at rear basement bedroom/closet wall -Provide full (3)2x4 support of the kitchen 16” lvl down to grade beam below **OK TO INSULATE
Gas Service Inspection - Residential Passed 4/12/2022 4/12/2022 04/12/2022
All Rough Inspection - Residential Partial 4/27/2022 4/27/2022 04/27/2022
Misc
Corrective Action Required
04/12/2022
-Provide fall protection for master bedroom windows **will check at final -Brace interior walls per plan **if brace by GP method, then I need to inspect screwing pattern @ 7” oc **OK TO ROCK. SEE INTERIOR WALL BRACING ABOVE
All Rough Inspection - Residential Passed 5/16/2022 5/16/2022 05/16/2022
Misc
Informational
05/16/2022
-Provide fall protection for master bedroom windows **will check at final
Sewer Service Inspection - R Passed 10/20/2022 (1:00) 10/20/2022 10/20/2022
Water Service Inspection - R Passed 10/21/2022 (9:15) 10/21/2022 10/21/2022
Driveway Inspection Partial 11/3/2022 11/3/2022 11/03/2022
Misc
Informational
11/03/2022
11-3-22 AN forms are in place and aggregate is present and compacted
Occupancy Inspection - Codes Residential Failed 11/17/2022 11/17/2022 11/17/2022
Misc
Corrective Action Required
11/17/2022
-Obtain lawn irrigation permit and submit backflow valve test report to city -Sidewalk and driveway not approved on record -Final grade, sod, downspout and sump pump extension -Provide two 1/2” through bolts at deck beam-post connection -Seal exterior wall penetrations; seal above AC disconnect, above trim, etc -Handrail profile not compliant. See handrail profile II of the IRC for details -Provide box extension for all electrical boxes recessed more than 1/4” behind non-combustible wall finish -Wiring shall be securely fasten within 12” of the kitchen island receptacle boxes. -Receptacle box shall be secured in place and not on moving door -Support mineral wool batts per code
Occupancy Inspection - Codes Residential Ready for Temp CO 11/18/2022 11/18/2022 11/18/2022
Misc
Corrective Action Required
11/17/2022
-Obtain lawn irrigation permit and submit backflow valve test report to city **application is still in incomplete status -Sidewalk and driveway not approved on record -Final grade, sod, downspout and sump pump extension -Return both ends of the basement stair handrail to wall.
Driveway Inspection Partial 11/4/2022 11/4/2022 11/28/2022
Misc
Informational
11/03/2022
11-3-22 AN forms are in place and aggregate is present and compacted 11-28-22 AN driveway looks good and meets Ada spec
Driveway Inspection Passed 11/28/2022
Misc
Informational
11/28/2022
11-3-22 AN forms are in place and aggregate is present and compacted 11-28-22 AN driveway looks good and meets Ada spec
Sidewalk Inspection Passed 11/28/2022
Misc
Informational
11/28/2022
11-28-22 AN sidewalk looks good and meets Ada spec
Erosion Control Inspection Residential Passed 01/03/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
11/17/2022
EROSION CONTROL REQUIRED ALONG THE FRONT STREET CURB
Occupancy Inspection - Codes Residential Full C of O 7/3/2023 07/03/2023
Misc
Resolved
07/03/2023
-Final grade, sod, downspout and sump pump extension
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit