Permit Application Status

PRRES20212850


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212850
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - UNCOVERED PATIO
06/03/2021
06/08/2021
12/01/2021
06/13/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOE@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $450.00 $450.00 Paid 06/08/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/08/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/08/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/08/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/08/2021
9110078-Valuation Fee New Single Family $1,107.53 $1,107.53 Paid 06/08/2021
9110078-Valuation Fee New Single Family $44.95 $44.95 Paid 09/02/2021
$1,152.48
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 10/22/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 7/23/2021 7/23/2021 07/23/2021
Misc
Resolved
07/23/2021
Footing Inspection - Residential Passed 7/23/2021 7/23/2021 07/23/2021
Misc
Informational
07/23/2021
APPROVED BY DAVID AINSWORTH 7/8/21
Sewer Service Inspection - R Passed 8/12/2021 (1:00) 8/12/2021 08/12/2021
Water Service Inspection - R Passed 8/20/2021 (10:00) 8/20/2021 08/20/2021
Erosion Control Inspection Residential Failed 8/20/2021 8/20/2021 08/20/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/20/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Gas Service Inspection - Residential Failed 1/31/2022 1/31/2022 01/31/2022
Misc
Corrective Action Required
01/31/2022
NOT READY FOR INSPECTION, GAS LINE BOND REQUIRED, CHECK PRESSURE AT REINSPECT
Underslab Plumbing Inspection - Residential Passed 1/31/2022 1/31/2022 01/31/2022
Electrical Service Inspection Failed 2/8/2022 2/8/2022 02/08/2022
Misc
Corrective Action Required
02/08/2022
REPLACE ACORN STYLE CLAMP WITH CLAMP RATED FOR REBAR CONNECTION, GEC TO UFER
Gas Service Inspection - Residential Failed 2/8/2022 2/8/2022 02/08/2022
Misc
Corrective Action Required
01/31/2022
GAS LINE BOND REQUIRED PRESSURE OK
All Rough Inspection - Residential Failed 2/8/2022 2/8/2022 02/08/2022
Misc
Corrective Action Required
02/08/2022
-upload engineer report to portal concerning overnotched studs for NM at garage portal -fireblock betrothal to horizontal at furred down soffit end 1st floor bath, add bocca plate at DWV at soffit line -fireblock HVAC/plumbing chase at great room -fireblock HVAC chase at great room windows -nail off all joist hangers at great room beam -land all electrical to boxes at flex room,basement stair wall 1st floor, basement den -structural straps at all top plates bored 50% or more at all interior load bearing walls and all exterior walls -Fireblock all tub and shower traps -CS-PF design at master bed windows per plans, nail exterior sheathing per plans/IRC R602.10.6.4 -address overnotched joist above basement bedroom egress window -gas line bond required -replace acorn style clamp with clamp rated for rebar connection, GEC to UFER -secure NM every 4.5’ through furred down -solid blocking every 48” oc between joists for kitchen island per plans -relocate water heater pex and electrical from mechanical room entry fireblock at finished basement den between top plate and foundation wall, seal all space around DWV and electrical
Erosion Control Inspection Residential Failed 2/8/2022 2/8/2022 02/08/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/08/2022
Misc
Corrective Action Required
02/08/2022
MAINTAIN GRAVEL FILTER AT DRIVE
Electrical Service Inspection Passed 2/22/2022 02/22/2022
Misc
Resolved
02/22/2022
Gas Service Inspection - Residential Passed 2/22/2022 02/22/2022
Misc
Resolved
02/22/2022
All Rough Inspection - Residential Failed 2/22/2022 2/22/2022 02/22/2022
Misc
Corrective Action Required
02/08/2022
-fireblock bump out at basement den, move electrical box , secure NM -bath exhaust fan required at basement bath -secure NM every 4.5’ through furred down **OK TO INSULATE**
All Rough Inspection - Residential Passed 3/7/2022 3/7/2022 03/07/2022
Misc
Resolved
03/07/2022
Driveway Inspection Partial 4/1/2022 4/1/2022 04/01/2022
Misc
Informational
04/01/2022
On Friday 4.1.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Sidewalk Inspection Partial 4/7/2022 4/7/2022 04/07/2022
Misc
Informational
04/07/2022
On 4.7.2022 Thursday I performed a sidewalk inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Failed 5/16/2022 5/16/2022 05/16/2022
Miscellaneous Correction
Corrective Action Required
05/16/2022
- Driveway inspection pending - Sidewalk inspection pending - Final grading and sod - Splash blocks - Sump discharge less than 36” away from foundation - Seal exterior penetrations - Seal top of meter can and A/C disconnect - Rock under stairs - Provide water drain back valve with back flow preventer
Sidewalk Inspection Passed 5/17/2022 5/17/2022 05/17/2022
Misc
Informational
04/07/2022
On 4.7.2022 Thursday I performed a sidewalk inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 5/17/2022 5/17/2022 05/17/2022
Misc
Informational
04/01/2022
On Friday 4.1.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Temporary C of O 5/17/2022 5/17/2022 05/17/2022
Miscellaneous Correction
Corrective Action Required
05/16/2022
- Final grading and sod - Splash blocks - Sump discharge less than 36” away from foundation - Seal exterior penetrations - Seal top of meter can and A/C disconnect -Provide code compliant handrail at front stairs -Provide gravel at water meter pit **OK FOR TCO, TCO EXPIRES 5/31/22**
Erosion Control Inspection Residential Partial 5/17/2022 5/17/2022 05/17/2022
Misc
Resolved
05/17/2022
MAINTAIN GRAVEL FILTER AT DRIVE
Occupancy Inspection - Codes Residential Temporary C of O 5/26/2022 05/26/2022
Miscellaneous Correction
Corrective Action Required
05/17/2022
- Final grading and sod - Splash blocks - Sump discharge less than 36” away from foundation - Seal exterior penetrations - Seal top of meter can and A/C disconnect -Provide code compliant handrail at front stairs -Provide gravel at water meter pit -correct water meter **OK FOR TCO, TCO EXPIRES 5/31/22**
Occupancy Inspection - Codes Residential Failed 6/9/2022 6/9/2022 06/09/2022
Miscellaneous Correction
Corrective Action Required
05/26/2022
- Splash blocks - MIN 36" DISCHARGE FROM FOUNDATION - Sump discharge less than 36” away from foundation -Provide code compliant handrail at front stairs
Erosion Control Inspection Residential Passed 06/09/2022
Plot Plan Inspection Passed 6/9/2022 6/9/2022 06/09/2022
Occupancy Inspection - Codes Residential Full C of O 6/13/2022 6/13/2022 06/13/2022
Miscellaneous Correction
Resolved
06/13/2022
Documents & Images
Date Uploaded File Type Document Name
06/03/2021 OS #41 - PERMIT APP
06/04/2021 Permit Codes Residential Plan Review
06/07/2021 Plot Plan Approved Plot Plan
06/07/2021 Drawing Approved Drawings
06/07/2021 Approved Plans Approved Truss Layout
06/07/2021 Approved Plans Approved Truss Package
06/07/2021 Permit Codes Residential Plan Review
06/08/2021 Permit DS Building Permit
06/08/2021 Receipt Receipt for transaction:2021-004109
07/09/2021 2102 SW Rutherford Dr LSMO Osage Lot 41 Clover & Hive P 2021-2850 3rd Party Footing Inspection Report 7-8-21
07/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
09/01/2021 21-0830 - OS #41 - Basswood - Basement Finish- signed
09/02/2021 Approved Plans Basement Finish Plan
09/02/2021 Receipt Receipt for transaction:2021-007096
10/22/2021 Receipt Receipt for transaction: 2021-008192
01/31/2022 Letter INSPECTION SUMMARY
01/31/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/22/2022 41 osage letter
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
03/07/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/07/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter Codes Temporary Certificate of Occupancy
05/17/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter Codes Temporary Certificate of Occupancy
05/26/2022 Email Osage Single Family Water Meters and TCO's
06/09/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter Codes Final Certificate of Occupancy
06/13/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home