Permit Application Status

PRRES20212435


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212435
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
05/12/2021
05/20/2021
11/08/2021
10/14/2022
Locations
Contacts
FIRST CHOICE CUSTOM HOMES LLC, Address:PO BOX 860072, Phone:(913) 449-8935  
fcchllc@yahoo.com  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ADVANCED ELECTRICAL LLC, Address:PO BOX 1573, Phone:(816) 347-8187  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK ST, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $630.00 $630.00 Paid 05/20/2021
Right of Way Permit Fee $80.00 $80.00 Paid 05/20/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/20/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 05/20/2021
Water Meter Fee $455.54 $455.54 Paid 05/20/2021
Valuation Fee New Single Family $1,267.96 $1,267.96 Paid 05/20/2021
8331504-EFHB Middle Big Creek, Full $703.08 $703.08 Paid 05/20/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/7/2021 (11:00) 7/7/2021 07/07/2021
Sewer Service Inspection - R Passed 8/25/2021 (1:15) 8/25/2021 08/25/2021
Underslab Plumbing Inspection - Residential Passed 8/26/2021 8/26/2021 08/26/2021
Water Service Inspection - R Passed 8/30/2021 (10:15) 8/30/2021 08/30/2021
Piers/Caissons Inspection - Residential Passed 12/16/2021 (1:00) 12/16/2021 12/16/2021
All Rough Inspection - Residential Failed 12/17/2021 12/17/2021 12/17/2021
Misc
Corrective Action Required
12/17/2021
-Nail top plate to header at garage PFG with 2 rows every 3” oc with 16D sinker nails -solid block between joists at garage wall, sgl car bay -fur down and bump out at garage wall and ceiling to allow for insulation -structural straps required at top plates bored 50% or more, all exterior walls and interior load bearing walls, straps min 16 ga 1 1/2" wide, span 6" across opening with min (4) 10D nailes each side of strap -complete DWV garage ceiling -address floor joist bored less than 2” from end of joist for DWV at a garage ceiling -add joist hangers at joist to lvl connection garage wall, cantilever not load bearing -secure all vertical DWV 2” or less at mid point -address overbored stud for DWV 1st floor west bath -fireblock all tub traps -nail all joist hangers kitchen breakfast -address (3) floor joists overbored for DWV kitchen/great room -Install patio door -bocca protection plates at top and bottom plate pex kitchen breakfast/great room wall -secure CSST gas line at fireplace and protect gas line to fireplace casing entry -3.5” SCH 40 steel column at garage beam per plans -2x10 joist dbl every other joist, 1st floor bed#5 per plans -address overbored stud for DWV 2nd floor laundry, south bath -bocca protection plate at top plate DWV 2nd floor bed#3 bath -no roof load on ceiling box out master bed per plans -collar ties every 48” oc -purlins per roof plans -Use clamp rated for GEC connection to rebar at UFER, dissimilar metal separation -set and anchor SCH 40 steel columns to floor at basement -nail all floor joists at basement -Unable to inspect sheathing nail pattern at garage portal due to siding cover -Gas line bond required -Nail all exterior sheathing per plans -only (2) conductor same type and size at same screw terminal of buss bar -Gas pressure at 0 psi, must maintain 10 psi for test
Electrical Service Inspection Failed 12/17/2021 12/17/2021 12/17/2021
Misc
Corrective Action Required
12/17/2021
-Use clamp rated for GEC connection to rebar at UFER, dissimilar metal separation -only (2) conductor same type and size at same screw terminal of buss bar
Gas Service Inspection - Residential Failed 12/17/2021 12/17/2021 12/17/2021
Misc
Corrective Action Required
12/17/2021
-Gas line bond required -Gas pressure at 0 psi, must maintain 10 psi for test
All Rough Inspection - Residential Failed 12/28/2021 12/28/2021 12/28/2021
Misc
Corrective Action Required
12/17/2021
12/28/21 - MET DENNIS WITH BUILDER ON SITE TO DISCUSS CORRECTIONS, COMPLETE CORRECTIONS AND RECALL FOR INSPECTION WHEN COMPLETE -Nail top plate to header at garage PFG with 2 rows every 3” oc with 16D sinker nails -solid block between joists at garage wall, sgl car bay -fur down and bump out at garage wall and ceiling to allow for insulation -structural straps required at top plates bored 50% or more, all exterior walls and interior load bearing walls, straps min 16 ga 1 1/2" wide, span 6" across opening with min (4) 10D nailes each side of strap -complete DWV garage ceiling -address floor joist bored less than 2” from end of joist for DWV at a garage ceiling -add joist hangers at joist to lvl connection garage wall, cantilever not load bearing -secure all vertical DWV 2” or less at mid point -address overbored stud for DWV 1st floor west bath -fireblock all tub traps -nail all joist hangers kitchen breakfast -address (3) floor joists overbored for DWV kitchen/great room -Install patio door -bocca protection plates at top and bottom plate pex kitchen breakfast/great room wall -secure CSST gas line at fireplace and protect gas line to fireplace casing entry -3.5” SCH 40 steel column at garage beam per plans -2x10 joist dbl every other joist, 1st floor bed#5 per plans -address overbored stud for DWV 2nd floor laundry, south bath -bocca protection plate at top plate DWV 2nd floor bed#3 bath -no roof load on ceiling box out master bed per plans -collar ties every 48” oc -purlins per roof plans -Use clamp rated for GEC connection to rebar at UFER, dissimilar metal separation -set and anchor SCH 40 steel columns to floor at basement -nail all floor joists at basement -Unable to inspect sheathing nail pattern at garage portal due to siding cover -Gas line bond required -Nail all exterior sheathing per plans -only (2) conductor same type and size at same screw terminal of buss bar -Gas pressure at 0 psi, must maintain 10 psi for test
Electrical Service Inspection Failed 1/4/2022 1/4/2022 01/04/2022
Misc
Corrective Action Required
12/17/2021
-Use clamp rated for GEC connection to rebar at UFER, dissimilar metal separation
Gas Service Inspection - Residential Failed 1/4/2022 1/4/2022 01/04/2022
Misc
Corrective Action Required
12/17/2021
-Gas pressure at 6 psi, must maintain 10 psi for test
All Rough Inspection - Residential Failed 1/4/2022 1/4/2022 01/04/2022
Misc
Corrective Action Required
12/28/2021
-fur down at HVAC garage ceiling to allow for insulation -address overbored stud for DWV 1st floor west bath -Install patio door -Use clamp rated for GEC connection to rebar at UFER, dissimilar metal separation -Gas pressure at 6 psi, must maintain 10 psi for test **OK TO INSULATE**
Erosion Control Inspection Residential Failed 1/11/2022 1/11/2022 01/11/2022
Misc
Corrective Action Required
01/11/2022
Maintain silt fence at perimeter and clean silt from storm inlet
All Rough Inspection - Residential Failed 1/11/2022 1/11/2022 01/11/2022
Misc
Corrective Action Required
01/04/2022
-fur down at HVAC garage ceiling to allow for insulation -address overbored stud for DWV 1st floor west bath **OK TO INSULATE**
Electrical Service Inspection Passed 1/11/2022 1/11/2022 01/11/2022
Misc
Resolved
01/11/2022
-Use clamp rated for GEC connection to rebar at UFER, dissimilar metal separation
Gas Service Inspection - Residential Passed 1/11/2022 1/11/2022 01/11/2022
Misc
Resolved
01/11/2022
-Gas pressure at 6 psi, must maintain 10 psi for test
All Rough Inspection - Residential Passed 1/12/2022 1/12/2022 01/12/2022
Misc
Resolved
01/12/2022
**OK TO INSULATE**
Occupancy Inspection - Codes Residential Failed 3/16/2022 3/16/2022 03/16/2022
Misc
Corrective Action Required
03/16/2022
-Final driveway and sidewalk inspection required, contact development services to schedule -submit as graded plot plan for review and approval -final grade and sod -GFCI protection required at 1st floor 1/2 bath receptacle -install spark rings on receptacles at kitchen counter, more than 1/4” setback to box -washing machine receptacle required to have GFCI protection -basement stairs handrail needs to terminate into safety post or newel post -install set screw on anti siphon at main water line spigot basement, after tightening screw make sure to shear the head off -min 31.9 circuit breaker ampacity for AC
Driveway Inspection Passed 2/14/2022 2/14/2022 03/17/2022
Misc
Informational
02/14/2022
On 2.14.2022 Monday I performed a driveway inspection and pass the subgrade to pour concrete
Sidewalk Inspection Passed 3/15/2022 3/15/2022 03/17/2022
Misc
Informational
03/16/2022
On March 15, 2022 I performed a sidewalk inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Temporary C of O 3/18/2022 3/18/2022 03/18/2022
Misc
Corrective Action Required
03/16/2022
-submit as graded plot plan for review and approval -final grade and sod **OK FOR TCO - TCO EXPIRES 4/15/22**
Plot Plan Inspection Passed 3/21/2022 03/21/2022
Driveway Inspection Passed 3/17/2022 3/17/2022 04/18/2022
Misc
Informational
02/14/2022
On 2.14.2022 Monday I performed a driveway inspection and pass the subgrade to pour concrete
Sidewalk Inspection Passed 3/17/2022 3/17/2022 07/12/2022
Misc
Informational
03/16/2022
On March 15, 2022 I performed a sidewalk inspection and pass the subgrade to pour concrete 7.12.2022 Sidewalk appears to be in compliance
Erosion Control Inspection Residential Passed 10/14/2022 10/14/2022 10/14/2022
Misc
Resolved
10/14/2022
Maintain silt fence at perimeter and clean silt from storm inlet
Occupancy Inspection - Codes Residential Full C of O 10/14/2022 10/14/2022 10/14/2022
Misc
Resolved
10/14/2022
-submit as graded plot plan for review and approval -final grade and sod **OK FOR TCO - TCO EXPIRES 4/15/22**
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home