Permit Application Status

PRRES20212185


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212185
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
05/03/2021
06/09/2021
10/31/2021
11/27/2023
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
DOUG@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,369.20 $1,369.20 Paid 06/09/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/09/2021
Right of Way Permit Fee $80.00 $80.00 Paid 06/09/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 06/09/2021
Water Meter Fee $455.54 $455.54 Paid 06/09/2021
8331507-Sewer Connection Fee $480.00 $480.00 Paid 06/09/2021
8331504-EFHB Middle Big Creek, Full $535.68 $535.68 Paid 06/09/2021
Not Ready Inspection Fee $75.00 $75.00 Paid 04/25/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 04/25/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 06/29/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 06/29/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 06/29/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 11/24/2023
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 7/6/2021 (3:30) 7/6/2021 07/06/2021
Misc
Corrective Action Required
07/06/2021
INSPECTION DENIED -EROSION CONTROL REQUIRED- - NO EROSION CONTROL ON LOT AT TIME OF INSPECTION, INSPECTED 7/6/21 2:40 PM -
Erosion Control Inspection Residential Failed 7/6/2021 7/6/2021 07/06/2021
Misc
Corrective Action Required
07/06/2021
-EROSION CONTROL REQUIRED- - NO EROSION CONTROL ON LOT AT TIME OF INSPECTION, INSPECTED 7/6/21 2:40 PM -
Footing Inspection - Residential Passed 7/9/2021 (1:00) 7/9/2021 07/09/2021
Misc
Resolved
07/09/2021
Underslab Plumbing Inspection - Residential Passed 8/6/2021 8/6/2021 08/06/2021
Sewer Service Inspection - R Passed 9/29/2021 (9:45) 9/29/2021 09/29/2021
Water Service Inspection - R Passed 10/1/2021 10/01/2021
Erosion Control Inspection Residential Failed 10/1/2021 10/1/2021 10/01/2021
Misc
Resolved
10/01/2021
-EROSION CONTROL REQUIRED- - NO EROSION CONTROL ON LOT AT TIME OF INSPECTION, INSPECTED 7/6/21 2:40 PM -
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/01/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 11/29/2021 11/29/2021 11/29/2021
All Rough Inspection - Residential Failed 11/29/2021 11/29/2021
Misc
Corrective Action Required
11/29/2021
-Garage portal PFH design requires dbl bottom plate with 5/8" bolt 2"x2"x3/16" flat washer -siding not nailed at top plate East garage wall, front dining, foyer -Nail all exterior sheathing per plans, several nails missed studs throughout -rafters landing on multiple blocks including smart siding at garage East wall, 2nd floor -seal all penetrations through air returns - (ceiling joists), 1st floor and basement -add joist hangers at 1st floor dining room ceiling joist, not currently bearing on load bearing wall just bump out -flash siding and snow block 2nd floor -add joist hanger 2nd floor north bedroom -2x6 exterior wall front foyer per plans -address 2nd floor load bearing wall load point transfer to 1st floor, no beam at 1st floor, beams and purlin struts supported by wall -support dbl lvl beam at stairs basement -anchor bolts required within 12” of plate breaks at basement, tighten all anchor bolts -anchor all steel columns to floor at basement -proper bearing stud packs at beams basement foundation -Install all windows and sliding glass door
Gas Service Inspection - Residential Passed 12/16/2021 12/16/2021 12/16/2021
All Rough Inspection - Residential Failed 12/16/2021 12/16/2021 12/16/2021
Misc
Corrective Action Required
11/29/2021
-seal all penetrations through air returns - (ceiling) basement -fireblock between top plates basement wall -fireblock vertical every 10’ between framing/foundation at basement wall
All Rough Inspection - Residential Passed 12/21/2021 12/21/2021 12/21/2021
Misc
Resolved
12/21/2021
Driveway Inspection Partial 4/8/2022 4/8/2022 04/08/2022
Misc
Informational
04/08/2022
On 4.8.2021 Friday I performed a driveway inspection and pass the subgrade to pour concrete
Occupancy Inspection - Codes Residential Failed 8/8/2022 8/8/2022 08/08/2022
Misc
Corrective Action Required
08/08/2022
-final driveway inspection required,contact development services to schedule -obtain lawn irrigation system permit -submit as graded plot plan for review and approval -no pier inspection performed on covered deck piers -install egress ladder at basement egress well -label all breaker locations at service panel, unable to verify electrical -label dedicated receptacle for sump pump as not GFCI protected -(2) 1/2” through bolts each post/beam connection covered deck -provide angle clips at inner ply of beam covered deck -seal all penetrations in siding -electrical receptacle required within 25’ of AC -provide extension at sump pump or splash block, min 36” discharge from foundation -provide gravel base at water meter pit -14”-18” allowed from top of water meter to top of lid
Occupancy Inspection - Codes Residential Not Ready 4/14/2023 4/14/2023 04/14/2023
Misc
Corrective Action Required
08/08/2022
-final driveway inspection required,contact development services to schedule -obtain lawn irrigation system permit -submit as graded plot plan for review and approval -no pier inspection performed on covered deck piers -install egress ladder at basement egress well -label all breaker locations at service panel, unable to verify electrical -label dedicated receptacle for sump pump as not GFCI protected -(2) 1/2” through bolts each post/beam connection covered deck -provide angle clips at inner ply of beam covered deck -seal all penetrations in siding -electrical receptacle required within 25’ of AC -provide extension at sump pump or splash block, min 36” discharge from foundation -provide gravel base at water meter pit -14”-18” allowed from top of water meter to top of lid 04/14/2023 Nothing on this list has been corrected
Driveway Inspection Passed 4/14/2023 4/14/2023 04/14/2023
Misc
Informational
04/08/2022
On 4.8.2021 Friday I performed a driveway inspection and pass the subgrade to pour concrete
Misc
Informational
04/14/2023
The driveway has been poured and is completed.
Piers/Caissons Inspection - Residential Passed 4/14/2023 04/14/2023
Occupancy Inspection - Codes Residential Failed 4/24/2023 04/24/2023
Misc
Corrective Action Required
04/14/2023
-submit as graded plot plan for review and approval -no pier inspection performed on covered deck piers -provide extension at sump pump min 36” discharge from foundation -provide gravel base at water meter pit -14”-18” allowed from top of water meter to top of lid -one joist hanger on the back patio is missing nails -all fees must be paid
Erosion Control Inspection Residential Passed 4/25/2023 04/25/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/25/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Ready for Temp CO 4/25/2023 04/25/2023
Misc
Corrective Action Required
04/24/2023
-submit as graded plot plan for review and approval -provide extension at sump pump min 36” discharge from foundation -provide gravel base at water meter pit -14”-18” allowed from top of water meter to top of lid -one joist hanger on the back patio is missing nails -all fees must be paid _TCO expiration 05-30-2023
Occupancy Inspection - Codes Residential Ready for Temp CO 5/25/2023 05/25/2023
Misc
Corrective Action Required
04/25/2023
-submit as graded plot plan for review and approval -provide extension at sump pump min 36” discharge from foundation -provide gravel base at water meter pit -14”-18” allowed from top of water meter to top of lid -one joist hanger on the back patio is missing nails -all fees must be paid _TCO expiration 05-30-2023
Occupancy Inspection - Codes Residential Failed 6/26/2023 06/26/2023
Misc
Corrective Action Required
05/25/2023
-submit as graded plot plan for review and approval -provide extension at sump pump min 36” discharge from foundation -provide gravel base at water meter pit -14”-18” allowed from top of water meter to top of lid -one joist hanger on the back patio is missing nails -all fees must be paid _TCO expiration 05-30-2023
Misc
Corrective Action Required
06/26/2023
TCO HAS EXPIRED PERMIT NOW IN NOTIC OF VIOLATION. Mitchell Schwarz 06/26/2023 10:45 AM
Occupancy Inspection - Codes Residential Ready for Temp CO 6/29/2023 06/29/2023
Misc
Corrective Action Required
06/26/2023
-submit as graded plot plan for review and approval -provide extension at sump pump min 36” discharge from foundation -provide gravel base at water meter pit -14”-18” allowed from top of water meter to top of lid -one joist hanger on the back patio is missing nails -all fees must be paid _TCO expiration 05-30-2023
Misc
Corrective Action Required
06/26/2023
TCO HAS EXPIRED PERMIT NOW IN NOTIC OF VIOLATION. Mitchell Schwarz 06/26/2023 10:45 AM
Plot Plan Inspection Passed 7/3/2023 07/03/2023
Occupancy Inspection - Codes Residential Ready for Temp CO 7/29/2023 08/02/2023
Misc
Corrective Action Required
06/29/2023
-submit as graded plot plan for review and approval -provide extension at sump pump min 36” discharge from foundation -provide gravel base at water meter pit -14”-18” allowed from top of water meter to top of lid -one joist hanger on the back patio is missing nails -all fees must be paid _TCO expiration 05-30-2023
Misc
Corrective Action Required
06/29/2023
TCO HAS EXPIRED PERMIT NOW IN NOTIC OF VIOLATION. Mitchell Schwarz 06/26/2023 10:45 AM
Occupancy Inspection - Codes Residential Full C of O 11/27/2023 11/27/2023
Misc
Resolved
11/27/2023
-submit as graded plot plan for review and approval -provide extension at sump pump min 36” discharge from foundation -provide gravel base at water meter pit -14”-18” allowed from top of water meter to top of lid -one joist hanger on the back patio is missing nails -all fees must be paid _TCO expiration 05-30-2023
Misc
Resolved
11/27/2023
TCO HAS EXPIRED PERMIT NOW IN NOTIC OF VIOLATION. Mitchell Schwarz 06/26/2023 10:45 AM
Documents & Images
Date Uploaded File Type Document Name
05/03/2021 Application Form Permit Application
05/04/2021 Application Form License Tax Form
05/04/2021 Permit Codes Residential Plan Review
06/09/2021 Plot Plan Approved Plot Plan
06/09/2021 Approved Plans Approved Drawings
06/09/2021 Permit Codes Residential Plan Review
06/09/2021 Permit DS Building Permit
06/09/2021 Receipt Receipt for transaction:2021-004247
07/06/2021 Letter INSPECTION SUMMARY
07/06/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
09/29/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
11/29/2021 Letter INSPECTION SUMMARY
11/29/2021 Letter INSPECTION SUMMARY
11/29/2021 Letter INSPECTION SUMMARY
12/15/2021 1809 Sage Canyon Modification Beam
12/16/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/21/2021 Letter INSPECTION SUMMARY
04/27/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/14/2023 Engineer Report/Study pier inspection
04/14/2023 Letter INSPECTION SUMMARY
04/14/2023 Letter INSPECTION SUMMARY
04/17/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter pier inspection
04/25/2023 Receipt Receipt for transaction:2023-002347
04/25/2023 Letter INSPECTION SUMMARY
04/25/2023 Certificate/License Codes Temporary Certificate of Occupancy
04/25/2023 Receipt Receipt for transaction:2023-002358
06/26/2023 Letter INSPECTION SUMMARY
06/26/2023 Letter INSPECTION SUMMARY
06/26/2023 Letter Codes 10 Day Letter
06/28/2023 Application Form EXTENSION FORM
06/29/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/29/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/29/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/29/2023 Receipt Receipt for transaction:2023-005055
06/30/2023 LOT 163 ASBUILT 6-29-23
06/30/2023 Plot Plan approved as graded plot plan
07/03/2023 Letter INSPECTION SUMMARY
11/24/2023 Certificate/License Codes Temporary Certificate of Occupancy
11/24/2023 Receipt Receipt for transaction:2023-008715
11/27/2023 Letter Codes Final Certificate of Occupancy
11/27/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home