Summary
PRRES20212071
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - COVERED DECK SIDEWALK WILL NOT COVER FRONTAGE OF THE PROPERTY, THE SIDEWALK TERMINATES IN ADA RAMP AT EDGE OF PROPERTY.
04/28/2021
04/29/2021
08/12/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/30/2021 04/29/2021
Brandon Kalwei
Residential Plan Review Approved 04/30/2021 04/28/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,185.93 $1,185.93 Paid 04/29/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 04/29/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/29/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/29/2021
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 04/29/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/29/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/29/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 7/8/2021 (1:00) 7/8/2021 07/08/2021
Water Service Inspection - R Passed 7/9/2021 (1:00) 7/9/2021 07/09/2021
Erosion Control Inspection Residential Failed 7/9/2021 7/9/2021 07/09/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/09/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 7/29/2021 7/29/2021 07/29/2021
Misc
Corrective Action Required
07/29/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION, SUBMIT ENGINEER REPORT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Failed 7/29/2021 7/29/2021 07/29/2021
Misc
Corrective Action Required
07/29/2021
FOOTING POURED WITHOUT INSPECTION, SUBMIT ENGINEER REPORT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Passed 8/3/2021 8/3/2021 08/03/2021
Misc
Informational
08/03/2021
APPROVED PER BRADLEY HUXOL 6/21/21
Underslab Plumbing Inspection - Residential Passed 8/3/2021 8/3/2021 08/03/2021
Misc
Resolved
08/03/2021
Erosion Control Inspection Residential Failed 8/3/2021 8/3/2021 08/03/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/09/2021
CLEAN ALL MUD AND GRAVEL FROM STREET
Electrical Service Inspection Passed 2/22/2022 2/22/2022 02/22/2022
Gas Service Inspection - Residential Failed 2/22/2022 2/22/2022 02/22/2022
Misc
Corrective Action Required
02/22/2022
-Gas line bond required pressure ok
All Rough Inspection - Residential Failed 2/22/2022 2/22/2022 02/22/2022
Misc
Corrective Action Required
02/22/2022
-fur down at garage ceiling to allow for insulation at HVAC -provide bocca protection plate at soffit line DWV garage wall -provide structural straps at top plates bored 50% or more all interior load bearing walls and all exterior walls, straps min 1 1/2” wide, 16 gauge, and must extend min 6” passed each side of opening with min (4) 10D nails each side of straps -fireblock HVAC chase garage entry -provide studs for bearing of plate at garage wall HVAC chase, studs removed for HVAC, min 16” oc stud spacing with load bearing wall -secure all vertical DWV 2” or less at mid point -solid block all sheathing breaks throughout -provide stud shoe 1st floor powder bath exterior stud bored for DWV -vent all mechanical bath fans to exterior -provide full bearing for blocking supporting D1-D3 trusses at 1st floor office -address corner top plate connection as required by code 1st floor office -provide stud shoes at studs bored for data tube 1st floor fireplace -dbl top plate requires min 24” offset between plate breaks - see 1st floor breakfast -provide protection plate at bottom plate fridge pex -provide stud shoes at exterior studs bored for DWV at master bath vanity -seal all top and bottom plate penetrations - see pantry -provide proper support for stair landings -EC#2 800 lb hold down device at master bed corner as noted on plans -provide (2) 2x4 stud pack at bearing end of (2) 2x10 along master bed wall to exterior exterior wall and at kitchen wall -CS-PF bracing design per plans at great room windows and dining room sliding door IRC R602.10.6.4 -repair sub floor front entry and kitchen -provide stud shoes at exterior studs bored for DWV 2nd floor bath -Fireblock deadspace at 2nd floor tub -address top plate connection 2nd floor stairs 2x6 wall -provide blocking and access for 1st attic at 2nd floor bedroom #4 per plans -minimum 30” vertical clearance at 2nd floor attic access -all truss lateral bracing per plans -provide bottom plate and (3) studs for corner as required per code at NE and SE corners basement -anchor bolts required within 12” of plate break at basement -install and tighten all nuts at anchor bolts basement -address floor joist notched at anchor bolt basement at garage wall, min 1 1/2” bearing required for wood -provide future vent for basement bath group -install exterior sheathing under deck near man door -nail all exterior sheathing per plans -gas line bond required
Gas Service Inspection - Residential Passed 3/4/2022 3/4/2022 03/04/2022
Misc
Resolved
03/04/2022
All Rough Inspection - Residential Failed 3/4/2022 3/4/2022 03/04/2022
Misc
Corrective Action Required
02/22/2022
-provide proper support for stair landings -EC#2 800 lb hold down device at master bed corner as noted on plans ( location moved address with engineer) - -address top plate connection 2nd floor stairs 2x6 wall -all truss lateral bracing per plans -address floor joist notched at anchor bolt basement at garage wall, min 1 1/2” bearing required for wood -provide future vent for basement bath group
All Rough Inspection - Residential Passed 3/9/2022 3/9/2022 03/09/2022
Misc
Resolved
03/09/2022
Driveway Inspection Partial 4/14/2022 4/14/2022 04/14/2022
Misc
Informational
04/14/2022
On 4.14.2021 Thursday I performed a driveway inspection and pass the subgrade to pour concrete
Piers/Caissons Inspection - Residential Passed 8/11/2022 08/11/2022
Erosion Control Inspection Residential Passed 8/11/2022 08/11/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
08/11/2022
CLEAN ALL MUD AND GRAVEL FROM STREET
Plot Plan Inspection Passed 8/11/2022 08/11/2022
Occupancy Inspection - Codes Residential Failed 8/11/2022 8/11/2022 08/11/2022
Misc
Corrective Action Required
08/11/2022
-address pending driveway inspection -address basement steps rise greater than 7 3/4” -address bottom step at deck stairs rise greater than 7 3/4 -address top step to basement greater than 7 3/4
Driveway Inspection Passed 8/12/2022 08/12/2022
Misc
Informational
04/14/2022
On 4.14.2021 Thursday I performed a driveway inspection and pass the subgrade to pour concrete 8.12.2022 Driveway appears to be compliant
Occupancy Inspection - Codes Residential Full C of O 8/12/2022 8/12/2022 08/12/2022
Misc
Resolved
08/12/2022
Documents & Images
Date Uploaded File Type Document Name
04/28/2021 Application Form APPLICATION
04/28/2021 101 MANOR AT STONEY CREEK TRUSS LAYOUT
04/28/2021 210341
04/28/2021 MN #101 - Waterford - Farmhouse - WO13x10C - Sheets- signed
04/28/2021 LOT 101 FINAL
04/28/2021 Approved Plans APPROVED PLANS
04/28/2021 Approved Plans APPROVED TRUSS DRAWINGS
04/28/2021 Approved Plans APPROVED TRUSS LAYOUT
04/29/2021 Receipt Receipt for transaction:2021-002327
04/29/2021 Letter DS Building Permit
07/08/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
08/02/2021 Lot 101 Manor at Stoney Creek Footing inspection
08/03/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
01/12/2022 Plot Plan APPROVED PLOT PLAN
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
03/04/2022 Letter INSPECTION SUMMARY
03/04/2022 101 manor at stoney creek letter
03/04/2022 Letter INSPECTION SUMMARY
03/04/2022 Letter INSPECTION SUMMARY
03/04/2022 101 manor at stoney creek letter #2
03/09/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter Field Certificate of Occupancy
08/12/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home