Permit Application Status

PRRES20211961


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211961
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
04/22/2021
05/12/2021
10/19/2021
02/16/2024
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
HIGGINBOTHAM.BRIAN@YAHOO.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/14/2021 05/12/2021
Kim Brennan
Basement opening elevations
Corrective Action Required
05/12/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. MDP shows it at 990.52
Planning Review (RES) Approved 04/26/2021 05/12/2021
Kim Brennan
Misc
Corrective Action Required
04/22/2021

Label the exterior building materials for each elevation.
Residential Plan Review Approved 05/14/2021 05/12/2021
Kim Brennan
Plot Plan Review Rejected 04/26/2021 04/22/2021
Kim Brennan
Basement opening elevations
Corrective Action Required
04/22/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. MDP shows it at 990.52
Residential Plan Review Approved 04/26/2021 04/22/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,070.95 $1,070.95 Paid 05/12/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/12/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/12/2021
8331504-EFHB Middle Big Creek, Full $535.68 $535.68 Paid 05/12/2021
8331507-Sewer Connection Fee $480.00 $480.00 Paid 05/12/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 05/12/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 05/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/06/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/06/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/14/2021 (1:00) 5/14/2021 05/14/2021
Erosion Control Inspection Residential Failed 6/10/2021 6/10/2021 06/10/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/10/2021
*6-10-21 -DEFICIENT EROSION CONTROL INSTALLATION. -EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -PROVIDE EROSION CONTROL AT SIDE OF LOT AND PROTECT STORM INLET
Underslab Plumbing Inspection - Residential Failed 6/15/2021 6/15/2021 06/15/2021
Misc
Corrective Action Required
06/10/2021
-Reconnect interior drain tile to exterior at northwest corner -Complete interior drain tile at south wall and ensure proper slope to exterior drains
Miscellaneous Correction
Corrective Action Required
06/10/2021
Erosion Control Inspection Residential Partial 6/15/2021 6/15/2021 06/15/2021
DCM3 ESC REQUIRED 2 DAY
Resolved
06/15/2021
Underslab Plumbing Inspection - Residential Passed 6/17/2021 6/17/2021 06/17/2021
Misc
Resolved
06/17/2021
-PREVIOUS INSPECTION PASSED IN ERROR 6-10 -CONTRACTOR HAS CALLED TO CANCEL INSPECTION
Miscellaneous Correction
Resolved
06/17/2021
-POST SITE ADDRESS
Sewer Service Inspection - R Passed 6/24/2021 (10:15) 6/24/2021 06/24/2021
Water Service Inspection - R Passed 6/24/2021 6/24/2021 06/24/2021
All Rough Inspection - Residential Not Ready 8/26/2021 08/26/2021
Misc
Corrective Action Required
08/26/2021
INSPECTION DENIED EROSION CONTROL REQUIRED AT FRONT OF LOT REPAIR DAMAGED SILT FENCE ON WEST SIDE PROPERTY LINE CLEAN ALL MUD BUILT UP AT GUTTER BUDDY AT STORM INLET AT FRONT OF LOT, CLEAN ANY MUD FROM STREET GRAVEL FILTER AT DRIVE, 4" LIFT REQUIRED
Erosion Control Inspection Residential Failed 8/26/2021 8/26/2021 08/26/2021
Misc
Corrective Action Required
08/26/2021
EROSION CONTROL REQUIRED AT FRONT OF LOT REPAIR DAMAGED SILT FENCE ON WEST SIDE PROPERTY LINE CLEAN ALL MUD BUILT UP AT GUTTER BUDDY AT STORM INLET AT FRONT OF LOT, CLEAN ANY MUD FROM STREET GRAVEL FILTER AT DRIVE, 4" LIFT REQUIRED
Electrical Service Inspection Passed 9/2/2021 9/2/2021 09/02/2021
Gas Service Inspection - Residential Failed 9/2/2021 9/2/2021 09/02/2021
Misc
Corrective Action Required
09/02/2021
-COMPLETE GAS LINE INSTALL AT FIREPLACE, PRESSURIZE LINE AFTER INSTALL FOR PRESSURE TEST, SECURE WARD FLEX GAS LINE AT FIREPLACE
All Rough Inspection - Residential Failed 9/2/2021 9/2/2021 09/02/2021
Misc
Corrective Action Required
08/26/2021
-Repair silt fence on west side of lot along neighboring property before rescheduling inspection, slope will carry silt into neighboring lot -Address East garage wall bottom plate, wall has all expansion anchor bolts for bottom plate and not anchor bolts embedded in concrete, also along garage PFH, engineer letter -Garage PFH, 5/8” diameter anchor bolt w/ 2” x 2” x 3/16” plate washer -studs 16” oc at master bed hall and master bed closet -complete gas line install at fireplace -secure ward flex gas line at fireplace -ridge support landed on NM at lvl above kitchen -purlins min 45 degrees -add collar ties front bedroom east side -12 x 45 steel beam to bear on HSS columns per plans at garage -CS-PF bracing design per plans at breakfast sgd, detail A4 in plans -Nail all exterior sheathing per plans WSP, 8D nails 6” edge, 12” field, no staples -No roof bearing on (3) 18” lvl great room per plans -Revise and submit plans to include covered deck, no pier inspection performed, submit engineer letter -seal gap between dbl wall at foyer hall east side -Add joist hanger to joists at stair wall s side, sgl to dbl joist connection and (2) sgl joist not supported by top plate -fireblock vertical to horizontal at furred down soffit ends -Anchor all SCH 40 steel columns in basement -Protection plate at top plate basement bath DWV **DECK NOT COMPLETE AT TIME OF ROUGH INSPECTION**
All Rough Inspection - Residential Failed 9/28/2021 9/28/2021 09/28/2021
Misc
Corrective Action Required
09/02/2021
-CS-PF bracing design per plans at breakfast sgd, detail A4 in plans -nail exterior sheathing per plans -Nail all exterior sheathing per plans WSP, 8D nails 6” edge, 12” field, no staples -Revise and submit plans, plot plan to include covered deck, no pier inspection performed, submit engineer letter OK TO INSULATE & ROCK
Gas Service Inspection - Residential Failed 11/3/2021 11/3/2021 11/03/2021
Misc
Corrective Action Required
09/02/2021
-GAS PRESSURE AT 8 PSI, MUST MAINTAIN 10 PSI FOR TEST
Gas Service Inspection - Residential Passed 11/5/2021 11/5/2021 11/05/2021
Misc
Resolved
11/05/2021
Driveway Inspection Partial 12/13/2021 12/13/2021 12/13/2021
Misc
Informational
12/13/2021
On Monday 12.13.2021 I performed a driveway inspection and pass the sub-grade to pour concrete
All Rough Inspection - Residential Not Ready 1/4/2022 1/4/2022 01/04/2022
Misc
Corrective Action Required
09/28/2021
1/4/22 - INSPECTION DENIED -ADDRESS EROSION CONTROL AT FRONT OF LOT -CLEAN ALL MUD FROM FRONT OF STORM INLET AT FRONT OF LOT -Garage PFH, 5/8” diameter anchor bolt w/ 2” x 2” x 3/16” plate washer -CS-PF bracing design per plans at breakfast sgd, detail A4 in plans -nail exterior sheathing per plans -Nail all exterior sheathing per plans WSP, 8D nails 6” edge, 12” field, no staples -Revise and submit plans, plot plan to include covered deck, no pier inspection performed, submit engineer letter OK TO INSULATE
Occupancy Inspection - Codes Residential Failed 1/6/2022 1/6/2022 01/06/2022
Misc
Corrective Action Required
01/06/2022
INSPECTION DENIED COMPLETE ALL CORRECTION FROM ALL ROUGH INSPECTION BEFORE SCHEDULING OCCUPANCY INSPECTION
Piers/Caissons Inspection - Residential Passed 1/7/2022 1/7/2022 01/07/2022
Misc
Informational
01/07/2022
(3) PIERS APPROVED PER CHAD M STREETER 7/13/21
All Rough Inspection - Residential Passed 1/7/2022 1/7/2022 01/07/2022
Misc
Informational
01/07/2022
EXTERIOR NAILING OF SHEATHING, CS-PF APPROVED PER AARON D OBERMILLER 1/6/22
Occupancy Inspection - Codes Residential Failed 1/7/2022 1/7/2022 01/07/2022
Misc
Corrective Action Required
01/06/2022
-Final driveway inspection required, contact development services to schedule -Submit as graded plot plan for review and approval -Final grade and sod -No setback allowed at box with combustible material, see electric receptacle at kitchen pantry counter, microwave receptacle, check basement wet bar -box setback per code at breakfast wall receptacles -Install downspout at gutter rear house -Splash blocks all downspout and sump pump locations, min 36” discharge from Foundation -seal all penetrations in siding APPROVED FOR OWNER TO STORE SOME BOXES IN GARAGE ONLY, NO FURNITURE/BOXES IN OTHER AREAS OF HOUSE UNTIL OCCUPANCY APPROVED, CONTRACTOR NEEDS TO BE PRESENT AT REINSPECT
Occupancy Inspection - Codes Residential Temporary C of O 1/10/2022 1/10/2022 01/10/2022
Misc
Corrective Action Required
01/07/2022
-Final driveway inspection required, contact development services to schedule -Submit as graded plot plan for review and approval -Final grade and sod -Install downspout at gutter rear house -Splash blocks all downspout and sump pump locations, min 36” discharge from Foundation -seal all penetrations in siding **OK FOR TCO, TCO EXPIRES 3/7/22**
Plot Plan Inspection Passed 1/27/2022 01/27/2022
Driveway Inspection Passed 11/2/2022 11/2/2022 11/02/2022
Misc
Informational
12/13/2021
On Monday 12.13.2021 I performed a driveway inspection and pass the sub-grade to pour concrete 11-2-22 RH. Meets LS specification.
Occupancy Inspection - Codes Residential Full C of O 2/16/2024 02/16/2024
Misc
Corrective Action Required
01/10/2022
-Final driveway inspection required, contact development services to schedule -Submit as graded plot plan for review and approval -Final grade and sod -Install downspout at gutter rear house -Splash blocks all downspout and sump pump locations, min 36” discharge from Foundation -seal all penetrations in siding **OK FOR TCO, TCO EXPIRES 3/7/22**
Documents & Images
Date Uploaded File Type Document Name
04/22/2021 Application Form Permit Application
04/22/2021 Application Form License Tax Form
04/22/2021 Letter Codes Residential Plan Review
05/12/2021 Approved Plans Approved Drawings
05/12/2021 Plot Plan Approved Plot Plan
05/12/2021 Letter Engineer Letter for MBOE
05/12/2021 Permit DS Building Permit
05/12/2021 Receipt Receipt for transaction:2021-002952
05/14/2021 1523 engineer report footing
05/14/2021 Letter INSPECTION SUMMARY
06/10/2021 Letter INSPECTION SUMMARY
06/10/2021 Letter INSPECTION SUMMARY
06/15/2021 Letter INSPECTION SUMMARY
06/15/2021 Letter INSPECTION SUMMARY
06/15/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
06/24/2021 Letter INSPECTION SUMMARY
06/24/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
09/02/2021 Letter INSPECTION SUMMARY
09/02/2021 Letter INSPECTION SUMMARY
09/02/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
09/28/2021 Photograph Rough Engineer letter
09/28/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/05/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/06/2022 1523 SW Blackstone Pl_DECK PIER INSP_2021-07-13
01/06/2022 Receipt Receipt for transaction:2022-000104
01/06/2022 Letter INSPECTION SUMMARY
01/06/2022 Plot Plan Approved Revised Plot Plan
01/07/2022 Letter INSPECTION SUMMARY
01/06/2022 Approved Plans Approved Revised Drawings
01/07/2022 Engineer Report/Study 21-002-23 KH-6107 Wall bracing panel inspection letter
01/07/2022 Letter INSPECTION SUMMARY
01/07/2022 Letter INSPECTION SUMMARY
01/10/2022 Letter Codes Temporary Certificate of Occupancy
01/26/2022 Plot Plan Approved As Graded Plot Plan
01/27/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home