Permit Application Status

PRRES20210673


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210673
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
02/22/2021
03/04/2021
08/21/2021
11/18/2021
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
FIRST CHOICE CUSTOM HOMES LLC, Address:PO BOX 860072, Phone:(913) 449-8935  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ADVANCED ELECTRICAL LLC, Address:PO BOX 1573, Phone:(816) 347-8187  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
fcchllc@yahoo.com  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/08/2021 03/04/2021
Kim Brennan
Spot elevations
Corrective Action Required
03/04/2021

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. Please provide drainage flow arrows thoughout the lot.
Basement egress
Corrective Action Required
03/04/2021

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
03/04/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Residential Plan Review Approved 03/08/2021 03/04/2021
Kim Brennan
Plot Plan Review Rejected 02/24/2021 02/22/2021
Kim Brennan
Spot elevations
Corrective Action Required
02/22/2021

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. Please provide drainage flow arrows thoughout the lot.
Basement egress
Corrective Action Required
02/22/2021

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
02/22/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Residential Plan Review Approved 02/24/2021 02/22/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $945.01 $945.01 Paid 03/04/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/04/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/04/2021
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 03/04/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 03/04/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/04/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/04/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/22/2021 (11:00) 3/22/2021 03/22/2021
Underslab Plumbing Inspection - Residential Failed 4/7/2021 4/7/2021 04/07/2021
Misc
Corrective Action Required
04/07/2021
INSPECTION DENIED -CLEAN ALL GRAVEL AND GRAVEL PILE FROM STREET IMMEDIATELY -CLEAN MUD FROM STREET -REPLACE STORM INLET PROTECTION AT STREET, CURRENT PROTECTION HAS DEGRADED AND NO LONGER OFFERING PROTECTION AS DESIGNED -POST ADDRESS ADDRESS ALL ISSUES BEFORE RESCHEDULING INSPECTION
Erosion Control Inspection Residential Failed 4/7/2021 4/7/2021 04/07/2021
Misc
Corrective Action Required
04/07/2021
-CLEAN ALL GRAVEL AND GRAVEL PILE FROM STREET IMMEDIATELY -CLEAN MUD FROM STREET -REPLACE STORM INLET PROTECTION AT STREET, CURRENT PROTECTION HAS DEGRADED AND NO LONGER OFFERING PROTECTION AS DESIGNED
Underslab Plumbing Inspection - Residential Passed 4/13/2021 4/13/2021 04/13/2021
Misc
Resolved
04/13/2021
Sewer Service Inspection - R Passed 6/25/2021 06/25/2021
Water Service Inspection - R Passed 7/1/2021 (10:30) 7/1/2021 07/01/2021
Erosion Control Inspection Residential Failed 7/16/2021 7/16/2021 07/16/2021
Misc
Resolved
07/16/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/16/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. CLEAN ALL MUD AND GRAVEL FROM STREET. MAINTAIN GRAVEL FILTER, 4" LIFT REQUIRED. ALL FUTURE INSPECTION DENIED UNTIL RESOLVED
Piers/Caissons Inspection - Residential Passed 7/16/2021 (1:00) 7/16/2021 07/16/2021
Electrical Service Inspection Passed 8/3/2021 8/3/2021 08/03/2021
Gas Service Inspection - Residential Failed 8/3/2021 8/3/2021 08/03/2021
Misc
Corrective Action Required
08/03/2021
Gas pressure at 0 psi, must maintain 10 psi for test
All Rough Inspection - Residential Failed 8/3/2021 8/3/2021 08/03/2021
Misc
Corrective Action Required
08/03/2021
-Unable to inspect 3” oc grid nail pattern at garage PFH due to cover -security blocking at garage man door and basement walkout -header to Jack stud tension straps at garage PFH R602.10.6.2 -anchor bolt 5/8” diam w/ 2” x 2” x 3/16” plate washer at garage PFH R602.10.6.2 -Add joist hangers at tail joist to attic access connection and (3) sgl joists to header between garage bays, over 4’ -add collar ties garage great room -Fireblock fireplace at great room open to attic space at master bed wall -Unable to inspect framing at covered deck, remove some panels to allow inspection -Seal NM top plate penetration at front entry closet -Electrical box at great room floor must be rated for floor use -Fireblock vertical to horizontal at all soffit ends of furred downs at finished basement -connect 2x4 laid flat at furred downs 3’ or more to floor joists above to support ceiling load at finished basement -Fireblock between top plate and either foundation wall or framing top plate at finished basement -Support pex above finished basement bath closet -seal all top plate penetrations at both finished basement bedrooms -3.5” SCH 40 steel column at W8x15 beam bearing end at basement rec room walkout corner per plans
All Rough Inspection - Residential Failed 8/9/2021 8/9/2021 08/09/2021
Misc
Corrective Action Required
08/03/2021
-3” grid nailing pattern required at sheathing to header garage PFH see R602.10.6.2 -Seal NM top plate penetration at front entry closet -Fireblock vertical to horizontal at all soffit ends of furred downs at finished basement - seal penetrations through fireblock and seal gaps between fireblock and foundation -Fireblock between top plate and either foundation wall or framing top plate at finished basement - see East wall at wet bar, East bath -seal all top plate penetrations at both finished basement bedrooms
Gas Service Inspection - Residential Failed 8/9/2021 8/9/2021 08/09/2021
Misc
Corrective Action Required
08/03/2021
Gas pressure at 0 psi, must maintain 10 psi for test
Erosion Control Inspection Residential Failed 8/9/2021 8/9/2021 08/09/2021
DCM3 ESC REQUIRED 2 DAY
Resolved
08/09/2021
Misc
Corrective Action Required
08/09/2021
MAINTAIN EROSION CONTROL AT FRONT OF LOT
Gas Service Inspection - Residential Failed 8/11/2021 8/11/2021 08/11/2021
Misc
Corrective Action Required
08/09/2021
Gas pressure at 5 psi, must maintain 10 psi for test
All Rough Inspection - Residential Failed 8/11/2021 8/11/2021 08/11/2021
Misc
Corrective Action Required
08/09/2021
-Seal NM top plate penetration at front entry closet -Fireblock between top plate and either foundation wall or framing top plate at finished basement - see East wall at wet bar, East bath - seal NM and pex penetrations through fireblock, remove Kraft paper from insulation, loose insulation used as fireblock must be unfaced -Address floor joist that has been cut for DWV above wet bar - this has been done in between inspections -seal all top plate penetrations at both finished basement bedrooms - see closet walls
All Rough Inspection - Residential Failed 8/13/2021 8/13/2021 08/13/2021
Misc
Corrective Action Required
08/11/2021
-Fireblock wall space at the wet bar from soffit **OK TO INSULATE
Gas Service Inspection - Residential Passed 8/13/2021 8/13/2021 08/13/2021
Misc
Resolved
08/13/2021
Gas pressure at 5 psi, must maintain 10 psi for test
All Rough Inspection - Residential Passed 8/16/2021 8/16/2021 08/16/2021
Misc
Resolved
08/16/2021
-Fireblock wall space at the wet bar from soffit **OK TO INSULATE
Driveway Inspection Passed 8/23/2021 8/23/2021 08/23/2021
Sidewalk Inspection Passed 8/23/2021 8/23/2021 08/23/2021
Driveway Inspection Passed 8/25/2021 8/25/2021 08/26/2021
Sidewalk Inspection Passed 8/25/2021 8/25/2021 08/26/2021
Occupancy Inspection - Codes Residential Failed 11/9/2021 11/9/2021 11/09/2021
Misc
Corrective Action Required
11/09/2021
-obtain irrigation permit -uncover water meter to check -splash blocks and sump pump discharge 36” from foundation -premises identification must comply with security code section 7-1404 -complete switch left side of fireplace -faceplates to be installed in kitchen and spark rings where needed per code section E906.6 -lable all non GFCI protected outlets in un-finished spaces. -garage receptacles must comply with code section E3901.9 -finish lighting basement bath -sheer off set screw for anti syphon device in basement -rear exterior light must comply with security code section 7-1409.2 -deck beams to columns per plan.
Plot Plan Inspection Passed 11/9/2021 11/9/2021 11/09/2021
Occupancy Inspection - Codes Residential Failed 11/12/2021 11/12/2021 11/12/2021
Misc
Corrective Action Required
11/09/2021
-uncover water meter to check -splash blocks and sump pump discharge 36” from foundation -premises identification must comply with security code section 7-1404 -deck beams to columns per plan. Mitchell Schwarz 11/12/2021 9:08 AM
Occupancy Inspection - Codes Residential Temporary C of O 11/16/2021 11/16/2021 11/16/2021
Misc
Corrective Action Required
11/12/2021
TCO UNTIL 11/30/21 -splash blocks must extend 36” from foundation.
Occupancy Inspection - Codes Residential Full C of O 11/18/2021 11/18/2021 11/18/2021
Misc
Resolved
11/18/2021
TCO UNTIL 11/30/21 -splash blocks must extend 36” from foundation.
Documents & Images
Date Uploaded File Type Document Name
02/22/2021 Application Form Permit Application
02/22/2021 Application Form License Tax Form
02/22/2021 Approved Plans Approved Drawings
02/22/2021 Letter Codes Residential Plan Review
03/04/2021 Plot Plan Approved Plot Plan
03/04/2021 Receipt Receipt for transaction:2021-001073
03/04/2021 Letter DS Building Permit
03/22/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/13/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
07/01/2021 Letter INSPECTION SUMMARY
07/16/2021 Letter INSPECTION SUMMARY
07/16/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/09/2021 Letter INSPECTION SUMMARY
08/09/2021 Letter INSPECTION SUMMARY
08/09/2021 Letter INSPECTION SUMMARY
08/11/2021 Letter INSPECTION SUMMARY
08/11/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
08/16/2021 Letter INSPECTION SUMMARY
08/23/2021 Letter INSPECTION SUMMARY
08/23/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
11/09/2021 Letter INSPECTION SUMMARY
11/09/2021 Letter INSPECTION SUMMARY
11/16/2021 Letter INSPECTION SUMMARY
11/16/2021 Letter Codes Temporary Certificate of Occupancy
11/18/2021 Letter Codes Final Certificate of Occupancy
11/18/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents