Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
BRIAN@HIGDONBUILDERS.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/20/2021 01/15/2021
Kim Brennan
Deck location
Corrective Action Required
01/15/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered deck
Lot elevations
Corrective Action Required
01/15/2021

Existing and finish elevations at all property corners must be provided on the plot plan. Please show finished elevations for the rear of the lot
Residential Plan Review Approved 01/20/2021 01/15/2021
Kim Brennan
Plot Plan Review Rejected 01/15/2021 01/13/2021
Kim Brennan
Deck location
Corrective Action Required
01/13/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered deck
Lot elevations
Corrective Action Required
01/13/2021

Existing and finish elevations at all property corners must be provided on the plot plan. Please show finished elevations for the rear of the lot
Residential Plan Review Approved 01/15/2021 01/13/2021
Kim Brennan
03 Two (2) plot plans
Corrective Action Required
01/13/2021

Missing Plot Plan
Plot Plan Review Rejected 01/13/2021 01/13/2021
Kim Brennan
Deck location
Corrective Action Required
01/13/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered deck
Lot elevations
Corrective Action Required
01/13/2021

Existing and finish elevations at all property corners must be provided on the plot plan. Please show finished elevations for the rear of the lot
Residential Plan Review Rejected 01/13/2021 01/11/2021
Kim Brennan
03 Two (2) plot plans
Corrective Action Required
01/11/2021

Missing Plot Plan
Planning Review (RES) Approved 01/13/2021 01/11/2021
Hector Soto Jr.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,235.86 $1,235.86 Paid 01/15/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/15/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/15/2021
8331504-EFHB Middle Big Creek, Full $703.08 $703.08 Paid 01/15/2021
8331507-Sewer Connection Fee $630.00 $630.00 Paid 01/15/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/15/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/15/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/15/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/24/2021 (8:00) 2/24/2021 02/24/2021
Underslab Plumbing Inspection - Residential Not Ready 3/15/2021 3/15/2021 03/15/2021
Misc
Corrective Action Required
03/15/2021
NO INSPECTION PERFORMED -POST SITE ADDRESS- -BACKFILL AT FOUNDATION FOR ACCESS TO INSPECT-
Underslab Plumbing Inspection - Residential Failed 4/8/2021 4/8/2021 04/08/2021
Misc
Corrective Action Required
03/15/2021
-SET INTERIOR DRAIN TILE, IF NO SUMP PUMP WITH WALKOUT DRAIN TILE MUST DISCHARGE TO DAYLIGHT WITH POSITIVE SLOPE
Underslab Plumbing Inspection - Residential Passed 4/16/2021 4/16/2021 04/16/2021
Misc
Resolved
04/16/2021
Sewer Service Inspection - R Partial 6/17/2021 (10:00) 6/17/2021 06/17/2021
Misc
Corrective Action Required
06/17/2021
-PARTIAL ON SEWER FROM HOUSE MID POINT DRIVE
Sewer Service Inspection - R Passed 6/18/2021 (9:00) 6/18/2021 06/18/2021
Misc
Resolved
06/18/2021
Water Service Inspection - R Passed 6/18/2021 6/18/2021 06/18/2021
All Rough Inspection - Residential Not Ready 6/29/2021 6/29/2021 06/29/2021
Misc
Corrective Action Required
06/29/2021
inspection denied , establish erosion control at front of lot. install gravel filter at drive 4" lift.
Electrical Service Inspection Failed 7/8/2021 7/8/2021 07/08/2021
Misc
Corrective Action Required
07/08/2021
-Remove panel bonding screw at service panel
Gas Service Inspection - Residential Failed 7/8/2021 7/8/2021 07/08/2021
Misc
Corrective Action Required
07/08/2021
-Complete gas line install at fireplace -Add shut off at future gas back patio **Pressure test will be performed after above corrections completed**
All Rough Inspection - Residential Failed 7/8/2021 7/8/2021 07/08/2021
Misc
Corrective Action Required
06/29/2021
-Firestop attic space -great room wall against master bed, along kitchen/great room wall, furred out wall in laundry, front entry/hall bath wall 1st floor, 1st floor stair wall master bed side -Firestop attic at fireplace wall East side -support hip rafter at front bedroom -support ridge at splice above front bedroom -support all vertical DWV 2” or less at mid point -24” offset required required at dbl top plate breaks, strap top plate- see E garage wall, 1st floor great room windows, basement den windows -Unable to inspect roof framing above covered deck,front porch remove some panels to allow inspection -Add joist hanger to ceiling joist to header connection above pantry -Add dbl joist hanger above master shower -Engineer letter needed on rafter/ceiling joist notch shimmed with smart siding trim -Add joist hangers to dbl and sgl joist above front entry -security blocking exterior doors -Fireblock deadspace at shower bump out walls 1st floor front shower -(2) king stud at great room windows per plans -(7) stud pack at garage steel I beam bearing ends per plans -Shim Jack studs at great room windows, cut short of header -Solid block between joists above beam, lateral restraint basement bed#3 -Complete wall framing and fireblock deadspace basement bath at bed#3 at shower -Add anchor bolt to bottom plate basement bed #3 and bed#4 N wall corner -Add joist hangers above unfinished space at laundry basement -sgl and dbl joists -Ensure UFER remains accessible at finish -Add shut off at future gas back patio -Complete gas line install at fireplace -Remove panel bonding screw at service panel **DECK INCOMPLETE AT ROUGH INSPECTION**
All Rough Inspection - Residential Failed 7/20/2021 7/20/2021 07/20/2021
Misc
Corrective Action Required
07/08/2021
-Firestop attic space -along kitchen/great room wall(seal gaps at fireblock), -24” offset required required at dbl top plate breaks, strap top plate- basement den windows
Electrical Service Inspection Passed 7/21/2021 7/21/2021 07/21/2021
Misc
Resolved
07/21/2021
All Rough Inspection - Residential Passed 7/21/2021 7/21/2021 07/21/2021
Misc
Resolved
07/21/2021
Gas Service Inspection - Residential Passed 7/21/2021 7/21/2021 07/21/2021
Misc
Resolved
07/21/2021
Driveway Inspection Passed 9/2/2021 09/02/2021
Misc
Informational
09/02/2021
On Thursday 9-2-2021 I inspected the subgrade for the driveway at 1526 SW Blackstone Place on the subgrade passed
Occupancy Inspection - Codes Residential Failed 10/14/2021 10/14/2021 10/14/2021
Misc
Corrective Action Required
10/14/2021
-Resolve outstanding inspection fee before final c of o -No pier inspection performed, submit engineer report -Final grade and sod -Splash blocks at all downspout and sump pump discharge, minimum 36" discharge from foundation - seal all penetrations in siding, seal along top of meter can and AC disconnect -Grocery door must be self closing -Complete guard at deck -smoke/co detector required outside front bedroom 1st floor, basement bedroom R315.3 -(2) 1/2” through bolts at each post/beam connection at deck -Install angle clips at ends outer ply deck
Piers/Caissons Inspection - Residential Failed 10/14/2021 10/14/2021 10/14/2021
Misc
Corrective Action Required
10/14/2021
PIERS POURED WITHOUT INSPECTION, SUBMIT ENGINEER REPORT
Occupancy Inspection - Codes Residential Temporary C of O 10/15/2021 10/15/2021 10/15/2021
Misc
Corrective Action Required
10/14/2021
-No pier inspection performed, submit engineer report -Final grade and sod -Gutters, downspouts, Splash blocks at all downspout and sump pump discharge, minimum 36" discharge from foundation - seal all penetrations in siding, seal along top of meter can and AC disconnect ***OK FOR TCO - TCO EXPIRES 10/29/21***
Erosion Control Inspection Residential Passed 1/7/2022 1/7/2022 01/07/2022
Plot Plan Inspection Passed 1/7/2022 1/7/2022 01/07/2022
Occupancy Inspection - Codes Residential Failed 1/7/2022 1/7/2022 01/07/2022
Misc
Corrective Action Required
10/15/2021
-No pier inspection performed, submit engineer report -Obtain lawn irrigation system permit
Piers/Caissons Inspection - Residential Passed 6/2/2022 6/2/2022 06/02/2022
Misc
Corrective Action Required
06/02/2022
APPROVED PER CHAD M STREETER 6/21/21
Occupancy Inspection - Codes Residential Full C of O 6/2/2022 6/2/2022 06/02/2022
Misc
Resolved
06/02/2022
Documents & Images
Date Uploaded File Type Document Name
01/08/2021 Application Form Permit Application
01/08/2021 Application Form License Tax Form
01/11/2021 Letter Codes Residential Plan Review
01/11/2021 Approved Plans Approved Drawings
01/13/2021 Letter Codes Residential Plan Review
01/15/2021 Plot Plan Approved Plot Plan
01/15/2021 Receipt Receipt for transaction:2021-000252
01/15/2021 Letter DS Building Permit
02/24/2021 FOOTING - SOIL REPORT .pdf
02/24/2021 Letter INSPECTION SUMMARY
03/15/2021 Letter INSPECTION SUMMARY
04/08/2021 Letter INSPECTION SUMMARY
04/16/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
06/29/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/20/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
09/02/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/15/2021 Receipt Receipt for transaction:2021-008005
10/15/2021 Letter Codes Temporary Certificate of Occupancy
01/07/2022 Letter INSPECTION SUMMARY
01/07/2022 Letter INSPECTION SUMMARY
01/07/2022 Letter INSPECTION SUMMARY
01/21/2022 Color1050
06/01/2022 Letter Codes 180 Day Letter
06/01/2022 Letter 1526 SW Blackstone Pl_DECK PIER INSP_2021-06-21
06/02/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter Field Certificate of Occupancy
06/02/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home