Summary
PRRES20203754
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - UNFINISHED BASEMENT - COVERED DECK
10/15/2020
10/28/2020
08/19/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/27/2020 10/28/2020
Dylan Eppert
As-graded plot plan
Corrective Action Required
10/26/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Planning Review (RES) Approved 10/27/2020 10/26/2020
Dylan Eppert
Residential Plan Review Approved 10/27/2020 10/26/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,356.07 $1,356.07 Paid 10/28/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 10/28/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 10/28/2020
Water Meter Fee $455.54 $455.54 Paid 10/28/2020
Right of Way Permit Fee $80.00 $80.00 Paid 10/28/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/28/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/12/2020 11/12/2020 11/12/2020
Underslab Plumbing Inspection - Residential Passed 12/17/2020 12/17/2020 12/17/2020
Electrical Service Inspection Passed 3/2/2021 3/2/2021 03/02/2021
Gas Service Inspection - Residential Passed 3/2/2021 3/2/2021 03/02/2021
All Rough Inspection - Residential Failed 3/2/2021 3/2/2021 03/02/2021
Misc
Corrective Action Required
03/02/2021
-12” oc nailing at all intersecting and abutting walls (braced walls) -seal all top and bottom plate penetrations -Fireblock all tub and shower traps -Secure gas flex line at fireplace -secure wall box and NM at front bedroom 1st floor - Provide header to jack stud straps PFH portal frame garage -Provide flashing and snow blocking 2nd floor bed#4 -Complete roof underlayment and shingle install, covered deck and front at garage/porch -Snow blocking at master closet, bed#3 -(4) stud pack at all girder truss bearing ends per plans -Address dbl girder truss bored/notched for DWV bed#2 2nd floor -Anchor all SCH 40 columns to floor in basement -Joist hanger at dbl joist connection to stair rim at stair wall in basement, over 4’ -(6) 2x6 stud pack at W10x39 steel beam bearing point per plans -provide roof vents at covered deck -Provide GFCI receptacle for jacuzzi tub -Provide anchor bolt within 12" of plate break near gas line -Nail all exterior sheathing per plans
All Rough Inspection - Residential Failed 3/12/2021 3/12/2021 03/12/2021
Misc
Corrective Action Required
03/02/2021
-12” oc nailing at all intersecting and abutting walls (braced walls) -fireblock at DWV vertical chase top at garage -(4) stud pack at all girder truss bearing ends per plans - see 2nd floor girders -Provide anchor bolt within 12" of plate break near gas line -Nail all exterior sheathing per plans
All Rough Inspection - Residential Passed 3/15/2021 3/15/2021 03/15/2021
Misc
Resolved
03/15/2021
Sewer Service Inspection - R Passed 3/31/2021 (11:30) 3/31/2021 03/31/2021
Water Service Inspection - R Passed 4/2/2021 (9:00) 4/2/2021 04/02/2021
Driveway Inspection Passed 5/3/2021 05/04/2021
Misc
Informational
05/04/2021
On Monday, 5-03-2021. A Driveway inspection was performed and passed inspection.
Sidewalk Inspection Passed 5/3/2021 05/04/2021
Misc
Informational
05/04/2021
On Monday, 5-03-2021. A city sidewalk inspection was performed and passed all standards.
Occupancy Inspection - Codes Residential Failed 6/17/2021 6/17/2021 06/17/2021
Misc
Corrective Action Required
06/17/2021
- final grade, check - as-graded plot plan -water meter leaking , pit full of water. lid needs to be flush with grade. -splash blocks, sump drain, gutters etc., sod. - deck: posts spliced not continuous deck posts. - sheetrock box out in garage. -label dedicated outlets, garage and basement. - install lag bolts at 16"o.c. - insude hangers installed at rim joist is not the correct hanger. install approved hanger.
Plot Plan Inspection Failed 7/23/2021 07/23/2021
Misc
Corrective Action Required
07/23/2021
-REMOVE ROCKS AND DEBRIS FROM SWALE, MAINTAIN VEGETATION AT SWALE, COMPLETE SOD TO SWALE
Plot Plan Inspection Passed 08/13/2021
Misc
Resolved
08/13/2021
-REMOVE ROCKS AND DEBRIS FROM SWALE, MAINTAIN VEGETATION AT SWALE, COMPLETE SOD TO SWALE
Occupancy Inspection - Codes Residential Failed 8/13/2021 8/13/2021 08/13/2021
Misc
Corrective Action Required
06/17/2021
-sump drain extension -sheetrock box out in garage
Occupancy Inspection - Codes Residential Full C of O 8/19/2021 8/19/2021 08/19/2021
Misc
Resolved
08/19/2021
Documents & Images
Date Uploaded File Type Document Name
10/15/2020 Application Form HT #33 - PERMIT APPLICATION 10.15.2020
10/23/2020 400692
10/23/2020 HT #33 - TRUSS LAYOUT
10/23/2020 HT #33 - Canterbury - Modern Farmhouse - Sheets- signed
10/23/2020 LOT 33 FINAL
10/26/2020 Plans APPROVED HOUSE PLAN
10/26/2020 Drawing APPROVED TRUSS LAYOUT
10/26/2020 Specifications APPROVED TRUSS PACKAGE
10/26/2020 Letter Codes Residential Plan Review
10/26/2020 Plans APPROVED ELEVATIONS
10/28/2020 Plot Plan APPROVED PLOT PLAN
10/28/2020 Receipt Receipt for transaction:2020-007235
10/28/2020 Letter DS Building Permit
11/11/2020 Lot 33 Hawthorne Ridge Footing Inspection
11/12/2020 Letter INSPECTION SUMMARY
11/30/2020 Lot 33 Hawthorne Ridge Wall Inspection
12/17/2020 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/11/2021 33 Truss fix
03/12/2021 Letter INSPECTION SUMMARY
03/15/2021 Letter INSPECTION SUMMARY
03/31/2021 Letter INSPECTION SUMMARY
04/02/2021 Letter INSPECTION SUMMARY
05/04/2021 Letter INSPECTION SUMMARY
05/04/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
07/21/2021 33 Hawthorne Ridge Non-continuous deck post letter
07/22/2021 Plot Plan APPROVED PLOT PLAN
07/23/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter Field Certificate of Occupancy
08/19/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home