Permit Application Status

PRRES20203376


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20203376
Building Permit - Residential
Certificate of Occupancy
MONTICELLO HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - ENGINEERED FLOOR SYSTEM - FINISHED BASEMENT - I JOIST FLOOR - COVERED PATIO
09/28/2020
10/26/2020
04/21/2021
08/11/2021
Locations
Contacts
MONTICELLO HOMES INC, Address:623 NE LONE HILL DR  
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
PERMITTING@JFECONSTRUCTION.COM  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/23/2020 10/23/2020
Dylan Eppert
Property boundary
Corrective Action Required
10/23/2020

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. PLOT PLAN SHOWS DISTANCE OF 34.25 PLAT SHOWS 35.83'
Sidewalks
Corrective Action Required
10/23/2020

Sidewalks with dimensions must be provided on the plot plan. MISSING SIDEWALK ON NE PARK RIDGE DR.
Basement egress
Corrective Action Required
10/23/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. MDP SHOTS THIS LOT TO BE A FULL NOT A DAYLIGHT. PLEASE SEND ENGINEERS LETTER TO ALLOW FOR THIS LOT TO HAVE A DAYLIGHT OR REVISE PLOT PLAN.
Residential Plan Review Approved 10/23/2020 10/23/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,576.93 $1,576.93 Paid 10/23/2020
8331507-Sewer Connection Fee $690.00 $690.00 Paid 10/23/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 10/23/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 10/23/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/23/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/23/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/20/2020 (11:30) 11/20/2020 11/20/2020
Underslab Plumbing Inspection - Residential Passed 12/11/2020 12/11/2020 12/11/2020
Sewer Service Inspection - R Passed 12/16/2020 (8:45) 12/16/2020 12/16/2020
Water Service Inspection - R Passed 12/17/2020 (1:15) 12/17/2020 12/17/2020
Piers/Caissons Inspection - Residential Passed 1/25/2021 01/25/2021
Informational
01/25/2021
engineer inspected and approved the piers
All Rough Inspection - Residential Failed 1/26/2021 1/26/2021 01/26/2021
Misc
Corrective Action Required
01/26/2021
-GARAGE PORTAL BRACE WALLS-OK
Gas Service Inspection - Residential Passed 4/6/2021 04/06/2021
Electrical Service Inspection Failed 4/6/2021 04/06/2021
Misc
Corrective Action Required
04/06/2021
-Connect the GEC to the grounded bus bar where the service grounded conductor is connected to; or install a #4 copper main bonding jumper from the grounding bus bar on the left to the grounded bus bar
All Rough Inspection - Residential Failed 4/6/2021 04/06/2021
Misc
Corrective Action Required
01/26/2021
FRAMING: -Code requires that the floor frame opening (for HVAC near oven) located more than 3 ft from supporting wall must have double trimmer joist -Solid block ends of joists above kitchen wall. Also required for exterior brace walls above -Anchor garage wall sill plate within 12” of break near stair -Fb bedroom wall from roof (wall above great room I beam); fb floor penetration at plumbing trap -Support bottom of valley rafter at rear bedroom. Install a 2x blocking underneath for support -Install lateral braces that were knocked out for the duct in basement (south side) ELECTRICAL: -Seal wiring penetrations of return air space -Protect wiring at rear dining bottom wall plate **OK TO INSULATE
Electrical Service Inspection Passed 4/12/2021 4/12/2021 04/12/2021
Misc
Resolved
04/12/2021
-Connect the GEC to the grounded bus bar where the service grounded conductor is connected to; or install a #4 copper main bonding jumper from the grounding bus bar on the left to the grounded bus bar
All Rough Inspection - Residential Failed 4/12/2021 4/12/2021 04/12/2021
Misc
Corrective Action Required
04/06/2021
-Fb bedroom wall from roof (wall above great room I beam); fb floor penetration at plumbing trap
All Rough Inspection - Residential Failed 4/14/2021 4/14/2021 04/14/2021
Misc
Corrective Action Required
04/12/2021
-Fb bedroom wall from roof (wall above great room I beam) **The wall is still open to the roof space. Use the same 1/2" wood strip to close off the top of the wall **OK TO INSULATE
All Rough Inspection - Residential Passed 04/15/2021
Misc
Resolved
04/15/2021
-Fb bedroom wall from roof (wall above great room I beam) **The wall is still open to the roof space. Use the same 1/2" wood strip to close off the top of the wall **OK TO INSULATE
Driveway Inspection Partial 6/2/2021 6/2/2021 06/02/2021
Misc
Informational
06/02/2021
Driveway - forms and materials passed pre-inspection.
Sidewalk Inspection Partial 6/2/2021 6/2/2021 06/02/2021
Misc
Informational
06/02/2021
Sidewalk - forms and materials passed pre-inspection.
Driveway Inspection Passed 6/4/2021 6/4/2021 06/04/2021
Misc
Informational
06/02/2021
Driveway - forms and materials passed pre-inspection.
Misc
Informational
06/04/2021
Driveway - passed final inspection.
Sidewalk Inspection Passed 6/4/2021 6/4/2021 06/04/2021
Misc
Informational
06/02/2021
Sidewalk - forms and materials passed pre-inspection.
Misc
Informational
06/04/2021
Sidewalk - passed final inspection.
Occupancy Inspection - Codes Residential Failed 7/29/2021 7/29/2021 07/29/2021
Misc
Corrective Action Required
07/29/2021
-Final grade, sod, downspout and sump pump extensions -Seal above service meter -Provide handrail for rear stair -Front stoop receptacle not giving-protected -Receptacle at 2nd fl rear bathroom sink not tripping -Provide receptacle at cabinet counter wall by fireplace -Provide separation of low voltage from normal power at fireplace switch -Provide secondary locks for slide doors -Kitchen countertop receptacles not gfci-protected -Receptacles located within 6 ft of the pantry sink shall be giving-protected -Install breaker lock for kitchen hood -Protect exposed TJI joists per code -Label lower breaker at sub panel -Locate and make accessible the sewer clean out -Secure the I beam support 2x8 to wall -Where’s the ufer grounding connection?
Occupancy Inspection - Codes Residential Temporary C of O 8/4/2021 8/4/2021 08/04/2021
Misc
Corrective Action Required
07/29/2021
-Final grade, sod, downspout and sump pump extensions -Provide handrail for rear stair -Provide secondary locks for slide doors -Secure the I beam support 2x8 to wall
Occupancy Inspection - Codes Residential Full C of O 8/11/2021 8/11/2021 08/11/2021
Misc
Resolved
08/11/2021
-Final grade, sod, downspout and sump pump extensions -Provide handrail for rear stair -Provide secondary locks for slide doors -Secure the I beam support 2x8 to wall
Documents & Images
Date Uploaded File Type Document Name
09/28/2020 1497_001
09/28/2020 1498_001
10/21/2020 PR-298
10/21/2020 Approved I- Joist Plan
10/21/2020 1909 NE PARK RIDGE DR_PERMIT_10-21-20
10/23/2020 Drawing APPROVED I JOIST PACKAGE
10/23/2020 Plans APPROVED HOUSE PLANS
10/23/2020 Letter Codes Residential Plan Review
10/23/2020 Plot Plan APPROVED PLOT PLAN
10/23/2020 Receipt Receipt for transaction:2020-007160
10/26/2020 Letter DS Building Permit
11/20/2020 Letter INSPECTION SUMMARY
11/20/2020 Letter Codes Residential Plan Review
12/11/2020 Letter INSPECTION SUMMARY
12/16/2020 Letter INSPECTION SUMMARY
12/17/2020 Letter INSPECTION SUMMARY
01/13/2021 Final_2020_12_30_GBSlab DPIer_LSMO_Concrete Design
01/25/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
04/06/2021 Letter INSPECTION SUMMARY
04/06/2021 Letter INSPECTION SUMMARY
04/06/2021 Letter INSPECTION SUMMARY
04/12/2021 Letter INSPECTION SUMMARY
04/12/2021 Letter INSPECTION SUMMARY
04/14/2021 Letter INSPECTION SUMMARY
04/15/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
06/02/2021 Letter INSPECTION SUMMARY
06/04/2021 Letter INSPECTION SUMMARY
06/04/2021 Letter INSPECTION SUMMARY
06/04/2021 Letter INSPECTION SUMMARY
06/04/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
08/04/2021 Letter Codes Temporary Certificate of Occupancy
08/11/2021 Letter Codes Final Certificate of Occupancy
08/11/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home