Permit Application Status

PRRES20202913


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202913
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS DEFERRED - FINISHED BASEMENT - COVERED DECK
09/09/2020
09/18/2020
03/14/2024
Locations
Contacts
ROESER HOMES LLC, Address:11415 STRANG LINE RD, Phone:(913) 220-7477  
MELISSA@ROESERHOMES.COM  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
ELECTRICAL INVESTMENTS, Address:8014 REEDER ST, Phone:(816) 210-1597  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/14/2020 09/17/2020
Dylan Eppert
Basement elevation
Corrective Action Required
09/14/2020

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.)
Basement egress
Corrective Action Required
09/14/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Spot elevations
Corrective Action Required
09/14/2020

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. SWALE C FLOW ARROWS ON THE PLOT PLAN ARE FLOWING NORTH PER THE MDP THE FLOW APPEARS TO BE GOING SOUTH. PLEASE VERIFY.
Residential Plan Review Approved 09/14/2020 09/14/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,543.13 $1,543.13 Paid 09/18/2020
8331507-Sewer Connection Fee $630.00 $630.00 Paid 09/18/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 09/18/2020
Water Meter Fee $455.54 $455.54 Paid 09/18/2020
Right of Way Permit Fee $80.00 $80.00 Paid 09/18/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/18/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/3/2020 (1:30) 11/3/2020 11/03/2020
Misc
Informational
11/03/2020
Provide third party pier inspection report within 48 hours
Underslab Plumbing Inspection - Residential Passed 12/7/2020 12/7/2020 12/07/2020
Erosion Control Inspection Residential Failed 01/21/2021
Misc
Corrective Action Required
01/21/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -no further inspections until issues are resolved
Sewer Service Inspection - R Passed 3/3/2021 (1:00) 3/3/2021 03/03/2021
Water Service Inspection - R Passed 3/4/2021 (1:00) 3/4/2021 03/04/2021
Erosion Control Inspection Residential Failed 03/10/2021
Misc
Corrective Action Required
01/21/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -no further inspections until issues are resolved
All Rough Inspection - Residential Failed 4/1/2021 4/1/2021 04/01/2021
Misc
Corrective Action Required
04/01/2021
-PFH detail on S-2.0 requires 3 bottom plates with 3” oc fastening per plate -Two rows of 16D sinker nails 3” oc at braced wall panel top plates per plan, see section view of detail -3” oc fastening at wall top plate per detail
Erosion Control Inspection Residential Failed 05/18/2021
Misc
Corrective Action Required
03/10/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -no further inspections until issues are resolved
All Rough Inspection - Residential Failed 5/28/2021 5/28/2021 05/28/2021
Misc
Corrective Action Required
04/01/2021
-PFH detail on S-2.0 requires 3 bottom plates with 3” oc fastening per plate -Two rows of 16D sinker nails 3” oc at braced wall panel top plates per plan, see section view of detail -3” oc fastening at wall top plate per detail
Misc
Corrective Action Required
05/28/2021
City approved plans required to be on site for inspections
Electrical Service Inspection Passed 6/9/2021 6/9/2021 06/09/2021
Gas Service Inspection - Residential Passed 6/9/2021 6/9/2021 06/09/2021
All Rough Inspection - Residential Failed 6/9/2021 6/9/2021 06/09/2021
Misc
Corrective Action Required
05/28/2021
-Complete exterior nailing pattern -Address columns not fully bearing on concrete at back deck -Provide (2) 1/2” bolts at all post to beam connection at deck -Uncover trusses and connections at deck -Fb vent at soffit line in garage -FB hvac chase at soffit line to prevent vertical to horizontal fire spread in garage -Strap top plate at south garage wall lapped less than 24” garage -Nail all corner studs 12” oc -Strap all dwv 2” and smaller at midpoint -Install roof boots throughout -Nail guard at nm by back door -Address no bearing at double girder truss above stairs -Bocca plate at pex in entry -3 studs required at exterior corners at master bath -Lower bocca plates to provide 2” of protection at master bath -Address trusses nailed to plywood at master bed and hallway -missing nails in hanger master bed -Strap top plates at master bed/great room -Strap top plate bored greater than 50% at master bath and upstairs bath south wall -3 studs in corners by basement kitchen -vertical FB basement kitchen 10’ oc maxm -Anchor bolt end of plate each side basement doors -tighten anchor bolts in basement -Vertical FB basement north wall 10’ oc max -Address over bored and over notched studs by electrical panel -top plate over notched for gas line north wall
Misc
Resolved
06/09/2021
City approved plans required to be on site for inspections
All Rough Inspection - Residential Passed 6/16/2021 6/16/2021 06/16/2021
Misc
Resolved
06/16/2021
-Complete exterior nailing pattern -Address columns not fully bearing on concrete at back deck -Provide (2) 1/2” bolts at all post to beam connection at deck -Uncover trusses and connections at deck -Fb vent at soffit line in garage -FB hvac chase at soffit line to prevent vertical to horizontal fire spread in garage -Strap top plate at south garage wall lapped less than 24” garage -Nail all corner studs 12” oc -Strap all dwv 2” and smaller at midpoint -Install roof boots throughout -Nail guard at nm by back door -Address no bearing at double girder truss above stairs -Bocca plate at pex in entry -3 studs required at exterior corners at master bath -Lower bocca plates to provide 2” of protection at master bath -Address trusses nailed to plywood at master bed and hallway -missing nails in hanger master bed -Strap top plates at master bed/great room -Strap top plate bored greater than 50% at master bath and upstairs bath south wall -3 studs in corners by basement kitchen -vertical FB basement kitchen 10’ oc maxm -Anchor bolt end of plate each side basement doors -tighten anchor bolts in basement -Vertical FB basement north wall 10’ oc max -Address over bored and over notched studs by electrical panel -top plate over notched for gas line north wall
Driveway Inspection Partial 9/8/2021 9/8/2021 09/08/2021
Misc
Informational
09/08/2021
Forms were placed and aggregate was present and compacted. RP 9-8-21
Driveway Inspection Passed 9/17/2021 9/17/2021 09/17/2021
Misc
Informational
09/08/2021
Forms were placed and aggregate was present and compacted. RP 9-8-21
Misc
Informational
09/17/2021
Finished driveway meets LS specs. RP 9-17-21
Occupancy Inspection - Codes Residential Failed 9/30/2021 9/30/2021 09/30/2021
Misc
Corrective Action Required
06/16/2021
**PROVIDE EROSION CONTROL ALONG THE STREET -Obtain lawn irrigation permit and submit the backflow test report to city -Final grade, sod, gutters, gutters, downspout and sump pump extensions -Make sure that the sewer tracer wire and port are installed and available at grade level -Seal exterior wall penetrations, seal above AC disconnect, meter, etc -Secure whip within. 12” of AC disconnect Provide guardrail at open side of front stoop more than 30” above surface below, as measured from 36” out from edge -Fb penetration of garage wall below sink -City amendment of the NEC requires all dedicated non-gfci receptacles in garage and unfinished basement to be identified (label, marking, etc) -Garage door not self closing -Install box extensions for switch & receptacle boxes recessed more than 1/4” behind kitchen countertop backsplash -Install box extension for fireplace switch and TV receptacle box recessed more than 1/4” from wall surface; separate the low voltage from 120v wiring at fireplace switch box -Pendant light in master bathroom is not allowed within bath tub zone -Handrail shall be continuous and uninterrupted -Provide gfci protection for all dish washers outlets per NEC 210.8(D) -Provide AFCI protectiotn for all outlets required per NEC 210.12 (washer, bar, dishwasher, fridge, kitchen, pantry, etc) -Install breaker lock for cooktop -Provide grounding clamp listed for connection to rebar -Bond gas piping -Plumbing in dedicated electrical space
Occupancy Inspection - Codes Residential Failed 10/1/2021 10/01/2021
Misc
Corrective Action Required
09/30/2021
**PROVIDE EROSION CONTROL ALONG THE STREET -Obtain lawn irrigation permit and submit the backflow test report to city -Final grade, sod, gutters, gutters, downspout and sump pump extensions -Make sure that the sewer tracer wire and port are installed and available at grade level -Seal exterior wall penetrations, seal above AC disconnect, meter, etc -Secure whip within. 12” of AC disconnect Provide guardrail at open side of front stoop more than 30” above surface below, as measured from 36” out from edge -Fb penetration of garage wall below sink -City amendment of the NEC requires all dedicated non-gfci receptacles in garage and unfinished basement to be identified (label, marking, etc) -Garage door not self closing -Install box extensions for switch & receptacle boxes recessed more than 1/4” behind kitchen countertop backsplash -Install box extension for fireplace switch and TV receptacle box recessed more than 1/4” from wall surface; separate the low voltage from 120v wiring at fireplace switch box -Pendant light in master bathroom is not allowed within bath tub zone -Handrail shall be continuous and uninterrupted -Provide gfci protection for all dish washers outlets per NEC 210.8(D) -Provide AFCI protectiotn for all outlets required per NEC 210.12 (washer, bar, dishwasher, fridge, kitchen, pantry, etc) -Install breaker lock for cooktop -Provide grounding clamp listed for connection to rebar -Bond gas piping -Plumbing in dedicated electrical space -Provide battery backup for the basement patio drain sump pump -Provide guardrail at open side of walking surface where more than 30" above the walkout basement patio floor
Occupancy Inspection - Codes Residential Failed 10/5/2021 10/5/2021 10/05/2021
Misc
Corrective Action Required
10/01/2021
-Obtain lawn irrigation permit and submit the backflow test report to city -Final grade, sod, gutters, gutters, downspout and sump pump extensions -Provide guardrail at open side of front stoop more than 30” above surface below, as measured from 36” out from edge -City amendment of the NEC requires all dedicated non-gfci receptacles in garage and unfinished basement to be identified (label, marking, etc) -Install box extension for fireplace switch and TV receptacle box recessed more than 1/4” from wall surface; -Handrail shall be continuous and uninterrupted-return to wall and must be able to withstand 200lbs of force
Occupancy Inspection - Codes Residential Temporary C of O 10/6/2021 10/6/2021 10/06/2021
Misc
Corrective Action Required
10/05/2021
TCO until 11-3-21 -Obtain lawn irrigation permit and submit the backflow test report to city -Final grade, sod, gutters, gutters, downspout and sump pump extensions
Plot Plan Inspection Passed 11/17/2021 11/17/2021
Occupancy Inspection - Codes Residential Full C of O 03/14/2024
Misc
Resolved
03/14/2024
TCO until 11-3-21 -Obtain lawn irrigation permit and submit the backflow test report to city -Final grade, sod, gutters, gutters, downspout and sump pump extensions
Documents & Images
Date Uploaded File Type Document Name
09/09/2020 Application Form License_Tax_Application
09/09/2020 Application Form Residental Permit Application 2019
09/09/2020 Final Plot Plan - Lot 1470 WV
09/09/2020 Engineered Plans - Lot 1470 WV
09/14/2020 Plans APPROVED HOUSE PLANS
09/14/2020 Letter Codes Residential Plan Review
09/17/2020 signed engineered letter lot 1470
09/17/2020 Plans APPROVED PLOT PLAN
09/18/2020 Receipt Receipt for transaction:2020-006334
09/18/2020 Letter DS Building Permit
10/22/2020 Plans APPROVED REVISED PLANS
10/22/2020 Drawing APPROVED TRUSS LAYOUT
10/22/2020 Specifications APPROVED TRUSS PACKAGE
11/03/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
03/03/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
03/10/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/28/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/16/2021 Letter INSPECTION SUMMARY
09/08/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter Codes Temporary Certificate of Occupancy
11/17/2021 Plot Plan Approved As Graded Plot Plan
11/17/2021 Letter INSPECTION SUMMARY
04/06/2022 Letter Codes 140 Day Letter
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home