Summary
PRRES20202150
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - FINISHED BASEMENT
08/03/2020
08/05/2020
06/23/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/05/2020 08/05/2020
Dylan Eppert
Residential Plan Review Approved 08/05/2020 08/05/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $981.03 $981.03 Paid 08/05/2020
8331506-EFHB Maybrook, Full $553.93 $553.93 Paid 08/05/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 08/05/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/05/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 08/05/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/05/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 08/05/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/20/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/22/2020 (3:00) 10/22/2020 10/22/2020
Underslab Plumbing Inspection - Residential Failed 11/12/2020 11/12/2020 11/12/2020
Misc
Corrective Action Required
11/12/2020
- BACKFILL AT FOUNDATION THAT WILL ALLOW FOR COMPLETE INSPECTION OF UNDERSLAB DWV AND INTERIOR DRAIN TILE
Underslab Plumbing Inspection - Residential Not Ready 11/13/2020 11/13/2020 11/13/2020
Misc
Corrective Action Required
11/12/2020
- BACKFILL AT FOUNDATION THAT WILL ALLOW FOR COMPLETE INSPECTION OF UNDERSLAB DWV AND INTERIOR DRAIN TILE - PROVIDE OSHA APPROVED ACCESS, EGRESS WELL AND LADDER IS NOT OSHA APPROVED ACCESS TO BASEMENT
Underslab Plumbing Inspection - Residential Passed 11/17/2020 11/17/2020 11/17/2020
Misc
Resolved
11/17/2020
Sewer Service Inspection - R Passed 1/19/2021 01/19/2021
Water Service Inspection - R Passed 1/20/2021 (10:30) 1/20/2021 01/20/2021
Erosion Control Inspection Residential Failed 1/25/2021 1/25/2021 01/25/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/25/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN SILT FENCE AT FRONT OF LOT -CLEAN MUD AND GRAVEL FROM STREET
Gas Piping Inspection - Residential Failed 2/10/2021 2/10/2021 02/10/2021
Miscellaneous Correction
Corrective Action Required
02/10/2021
-Support horizontal metallic gas line per code
Gas Service Inspection - Residential Failed 2/10/2021 2/10/2021 02/10/2021
Misc
Corrective Action Required
02/10/2021
-Support horizontal metallic gas line per code
Electrical Service Inspection Passed 2/10/2021 2/10/2021 02/10/2021
All Rough Inspection - Residential Failed 2/10/2021 2/10/2021 02/10/2021
Miscellaneous Correction
Corrective Action Required
02/10/2021
-Unable to verify exterior nailing pattern at PFH -Nail exterior sheathing 12” o.c in field and 6” o.c. at perimeter and seams -Tension straps at PFH -Seal all plate penetrations -Seal gap in top of dead space in garage -Provide top plate at fur out in garage at radon -Seal rim joist at radon -Provide anchor bolts in garage at single car bay, at ends of walls east and west, and at plate break on east wall. -Anchor bolts on east wall to be within middle third of plate -Nail corners and intersecting walls per code -Fireblock tub traps -Seal all penetrations between floors -Seal penetrations between floors in fireplace dead space -Address truss member cut out for roof vent at dining room -Roof vents covered by truss framing at foyer and garage -Provide clearance for B vent at truss bracing -Missing EC2 all locations -Minimum (4) 2x4 stud pack required at girder truss bearing locations -Seal dead spaces at cased openings -Fireblock soffit lines in basement -Support metallic gas line per code -Insulate cantilevers -Provide vertical fireblocking max. 10’ o.c. In fur out wall in basement -Seal gaps in fireblocking at top of fur out wall -Anchor bottom plate in basement walls per code -Provide truss bracing per plans
All Rough Inspection - Residential Failed 2/19/2021 2/19/2021 02/19/2021
Miscellaneous Correction
Corrective Action Required
02/10/2021
-Unable to verify exterior nailing pattern at PFH -Nail exterior sheathing 12” o.c in field and 6” o.c. at perimeter and seams -Address truss member cut out for roof vent at dining room -Roof vents covered by truss framing at foyer and garage -Provide clearance for B vent at truss bracing -Missing EC2 all locations -Support metallic gas line per code -Provide truss bracing per plans **OK TO INSULATE**
All Rough Inspection - Residential Failed 2/25/2021 2/25/2021 02/25/2021
Miscellaneous Correction
Corrective Action Required
02/19/2021
-Maintain gravel filter, clean mud and gravel from street -Address truss member cut out for roof vent at dining room - engineer letter from truss manufacturer required -Roof vents covered by truss framing at foyer and garage **OK TO INSULATE**
Erosion Control Inspection Residential Failed 2/25/2021 2/25/2021 02/25/2021
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/25/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN SILT FENCE AT FRONT OF LOT -CLEAN MUD AND GRAVEL FROM STREET
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/25/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -MAINTAIN GRAVEL FILTER- -CLEAN ALL MUD AND GRAVEL FROM STREET-
All Rough Inspection - Residential Failed 3/2/2021 3/2/2021 03/02/2021
Miscellaneous Correction
Corrective Action Required
02/25/2021
-Maintain gravel filter, clean mud and gravel from street -Roof vents covered by truss framing at foyer and garage ** OK TO INSULATE, OK TO ROCK WALLS ONLY NOT CEILING LINE UNTIL ALL ROUGH PASSED**
All Rough Inspection - Residential Passed 3/4/2021 3/4/2021 03/04/2021
Miscellaneous Correction
Resolved
03/04/2021
Gas Service Inspection - Residential Passed 03/04/2021
Misc
Resolved
03/04/2021
Gas Piping Inspection - Residential Passed 03/04/2021
Miscellaneous Correction
Resolved
03/04/2021
-Support horizontal metallic gas line per code
Driveway Inspection Partial 3/11/2021 3/11/2021 03/12/2021
Misc
Informational
03/12/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 3/11/2021 3/11/2021 03/12/2021
Misc
Informational
03/12/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 3/19/2021 3/19/2021 03/22/2021
Misc
Informational
03/12/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Failed 3/19/2021 3/19/2021 03/22/2021
Misc
Resolved
03/22/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Corrective Action Required
03/22/2021
John DiMauro 3/22/2021 POST POUR INSPECTION FAILED (SEE COMMENTS) The sidewalk meets compliance but it is not complete. There is a section of the sidewalk that has not been installed due to landscaping around a sanitary sewer manhole that is obstructing the sidewalk. Corrections need to be complete prior to acceptance of the entire sidewalk.
Occupancy Inspection - Codes Residential Failed 5/4/2021 5/4/2021 05/04/2021
Misc
Corrective Action Required
05/04/2021
-Pay all fees due before final occupancy -Provide erosion control at back of house before any further inspections -Sidewalk inspection still pending -Final grade and sod -Splash blocks and sump discharge -Adjust garage door to be self closing and latching -Install door hardware on garage door -Install receptacles, spark rings, and cover plates at floor boxes in living and dining rooms -1" clearance to combustibles required at B vent at furnace -Receptacle required within 25' of furnace -Provide anti-syphon device at hose bib
Sidewalk Inspection Passed 05/13/2021
Misc
Corrective Action Required
03/22/2021
John DiMauro 3/22/2021 POST POUR INSPECTION FAILED (SEE COMMENTS) The sidewalk meets compliance but it is not complete. There is a section of the sidewalk that has not been installed due to landscaping around a sanitary sewer manhole that is obstructing the sidewalk. Corrections need to be complete prior to acceptance of the entire sidewalk. Joe Starlin 5-13-21 1:37pm The sidewalk panel has been installed.
Occupancy Inspection - Codes Residential Temporary C of O 5/20/2021 5/20/2021 05/20/2021
Misc
Corrective Action Required
05/04/2021
-Final grade and sod -Splash blocks and sump discharge **OK FOR TCO - TCO EXPIRES 6/10/21**
Occupancy Inspection - Codes Residential Temporary C of O 6/17/2021 6/17/2021 06/17/2021
Misc
Corrective Action Required
05/20/2021
-REPLACE VEGETATION DISTURBED FROM CONSTRUCTION ALONG REAR OF LOT **OK FOR TCO - TCO EXPIRES 6/25/21**
Plot Plan Inspection Passed 6/17/2021 6/17/2021 06/17/2021
Erosion Control Inspection Residential Passed 06/17/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/17/2021
Occupancy Inspection - Codes Residential Full C of O 6/23/2021 6/23/2021 06/23/2021
Misc
Resolved
06/23/2021
Documents & Images
Date Uploaded File Type Document Name
08/03/2020 Application Form RR #77 - PERMIT APP
08/03/2020 LOT 77 FINAL
08/03/2020 RR #77 - Juliette - Old World - Sheets- signed
08/03/2020 400422
08/03/2020 77 RESERVE AT STONEY CREEK ROOF LAYOUT- signed
08/05/2020 Drawing APPROVED TRUSS LAYOUT
08/05/2020 Specifications APPROVED TRUSS PACKAGE
08/05/2020 Plans APPROVED HOUSE PLANS
08/05/2020 Plot Plan APPROVED PLOT PLAN
08/05/2020 Receipt Receipt for transaction:2020-004981
08/05/2020 Letter DS Building Permit
10/22/2020 Letter INSPECTION SUMMARY
10/27/2020 Engineer Report/Study 7329-2
11/12/2020 Letter INSPECTION SUMMARY
11/13/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/25/2021 Letter INSPECTION SUMMARY
02/10/2021 Letter INSPECTION SUMMARY
02/10/2021 Letter INSPECTION SUMMARY
02/10/2021 Letter INSPECTION SUMMARY
02/10/2021 Letter INSPECTION SUMMARY
02/19/2021 Letter INSPECTION SUMMARY
02/23/2021 RR77 Truss letter
02/25/2021 Letter INSPECTION SUMMARY
02/25/2021 Letter INSPECTION SUMMARY
03/01/2021 RR77 Reserve at Stoney Creek Cut Truss Letter
03/02/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
03/12/2021 Letter INSPECTION SUMMARY
03/12/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
05/04/2021 Letter INSPECTION SUMMARY
05/13/2021 Letter INSPECTION SUMMARY
05/20/2021 Receipt Receipt for transaction:2021-003270
05/20/2021 Letter Codes Temporary Certificate of Occupancy
06/17/2021 Letter Codes Temporary Certificate of Occupancy
06/17/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
06/23/2021 Letter Field Certificate of Occupancy
06/23/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home