Permit Application Status

PRRES20202006


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202006
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK CLOSED WITH OPEN VIOLATIONS OR EXCEEDED PERMIT LIMITS
07/21/2020
07/31/2020
02/27/2024
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 346  
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
JIM@SABHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/23/2020 07/23/2020
Kim Brennan
Deck location
Corrective Action Required
07/22/2020

Deck location, with dimensions to property lines must be provided on the plot plan. Please show that this is a covered deck
As-graded plot plan
Corrective Action Required
07/22/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 07/23/2020 07/23/2020
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
07/21/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) Please provide square footage for covered deck, garage and unfinished basement
Misc
Corrective Action Required
07/21/2020

Electrical contractor does not have a valid business license.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $987.07 $987.07 Paid 07/31/2020
Right of Way Permit Fee $80.00 $80.00 Paid 07/31/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/31/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 07/31/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 07/31/2020
Water Meter Fee $455.54 $455.54 Paid 07/31/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Water Service Inspection - R Passed 8/19/2020 (1:00) 8/19/2020 at 1:15 PM 08/19/2020
Underslab Plumbing Inspection - Residential Passed 8/20/2020 8/20/2020 08/19/2020
Sewer Service Inspection - R Passed 8/27/2020 (8:45) 8/27/2020 08/27/2020
Footing Inspection - Residential Passed 9/25/2020 09/25/2020
Informational
09/25/2020
FOOTING INSPECTED AND APPROVED BY ENGINEER
Piers/Caissons Inspection - Residential Passed 9/25/2020 09/25/2020
Electrical Service Inspection Passed 11/11/2020 11/11/2020 11/11/2020
Gas Service Inspection - Residential Passed 11/11/2020 11/11/2020 11/11/2020
All Rough Inspection - Residential Failed 11/11/2020 11/11/2020 11/11/2020
Misc
Corrective Action Required
11/11/2020
FRAMING: -Garage PFH wall: nail sheathing per code. Expose all nailing -Fb front bedroom wall from roof -Provide full bearing for timber beams at front bedroom -Complete framing of b-vent chase and Fb from attic space -Install hanger for foyer lvl ceiling beam -Provide full bearing for roof beams in garage; nail together both plies of beams -Provide hanger support for ceiling joists in garage -Sister a stud to each stud with over-cut bottom and nail to sill plate; shim all gap under studs; install anchor washers and nuts; anchor sill plates within 12” of break -Nail all corner studs with 16d@12” oc or equivalent nailing -Nail exterior wall sole plates per code -Install hangers for master bedroom and nail all hangers per code -Provide (5)2x4 support for lvl beam at cooktop -Nail together lvl beam per code -Fb basement wall vertically at interval ten ft or less -Anchor basement sill plate per code; min 2 anchors per short plate; add washers where required for secure anchoring; anchor all columns -Provide full width bearing for basement I beam at walkout door -Solid block joist end above I beam -Insulate first, then solid block dining cantilevered joists to bearing wall -Fb basement wall from ceiling space and soffit -Toe nail all joists to top plates with 4-8d or 3-10d -Provide bearing for joist near ufer rebar -Install hanger support above water heater location -Solid block underneath master bedroom lvl beam point load MECHANICAL: -Current code no longer allows dryer duct to be distorted from its round shape ELECTRICAL: -Install a smoke alarm near top of great room ceiling outside master bedroom. Stay min ten ft from cooking appliance **DO NOT INSULATE
All Rough Inspection - Residential Failed 11/19/2020 11/19/2020 11/19/2020
Misc
Corrective Action Required
11/11/2020
FRAMING: -Provide full bearing for timber beams at front -Provide full bearing for roof beams in garage; nail together both plies of beams- -Sister a stud to each stud with over-cut bottom and nail to sill plate; shim all gap under studs; install anchor washers and nuts; anchor sill plates within 12” of break -Install hangers for master bedroom and NAIL all hangers per code EXT WALL NEAR BATH -Insulate first, then solid block dining cantilevered joists to **DO NOT INSULATE
All Rough Inspection - Residential Passed 11/23/2020 11/23/2020 11/23/2020
Misc
Resolved
11/24/2020
FRAMING: -Provide full bearing for timber beams at front -Provide full bearing for roof beams in garage; nail together both plies of beams- -Sister a stud to each stud with over-cut bottom and nail to sill plate; shim all gap under studs; install anchor washers and nuts; anchor sill plates within 12” of break -Install hangers for master bedroom and NAIL all hangers per code EXT WALL NEAR BATH -Insulate first, then solid block dining cantilevered joists to **DO NOT INSULATE
Driveway Inspection Partial 2/3/2021 (Ready Now) 2/3/2021 02/03/2021
Misc
Informational
02/03/2021
Driveway - forms and materials passed pre-inspection.
Sidewalk Inspection Partial 2/3/2021 (Ready Now) 2/3/2021 02/03/2021
Misc
Informational
02/03/2021
Sidewalk - forms and materials passed pre-inspection.
Driveway Inspection Passed 2/5/2021 2/5/2021 02/05/2021
Misc
Informational
02/03/2021
Driveway - forms and materials passed pre-inspection.
Misc
Informational
02/05/2021
Driveway - (appears to be with in specifications it was not covered for cold weather conditions which is the contractor responsibility.) Driveway passed the final inspection.
Sidewalk Inspection Passed 2/5/2021 2/5/2021 02/05/2021
Misc
Informational
02/03/2021
Sidewalk - forms and materials passed pre-inspection.
Misc
Informational
02/05/2021
Sidewalk - (see notes on driveway) passed final inspection.
Occupancy Inspection - Codes Residential Failed 2/23/2021 2/23/2021 02/23/2021
Misc
Corrective Action Required
02/23/2021
-If lawn irrigation is installed, obtain lawn irrigation permit and submit the backflow test report to city -As-graded plot plan is required prior to sodding. This includes walk-up basement patio to grade; complete retaining wall around basement patio; grading shall slope away from building and away from basement patio -Foundation drain shall be repaired and drain to daylight -Final grade, sod, downspout and sump pump extensions -Make sure that the sewer tracer wire and port are installed and available at grade level -Lag deck ledger board to rim band -Install security compliant light outside basement slide door -Remove obstruction from basement for inspection -Provide battery backup for sump pump
Occupancy Inspection - Codes Residential Temporary C of O 2/24/2021 02/24/2021
Misc
Corrective Action Required
02/23/2021
-If lawn irrigation is installed, obtain lawn irrigation permit and submit the backflow test report to city -As-graded plot plan is required prior to sodding. This includes walk-up basement patio to grade; complete retaining wall around basement patio; grading shall slope away from building and away from basement patio -Foundation drain shall be repaired -Final grade, sod, downspout and sump pump extensions -Make sure that the sewer tracer wire and port are installed and available at grade level -Lag deck ledger board to rim band -Install security compliant light outside basement slide door -Provide battery backup for sump pump
Documents & Images
Date Uploaded File Type Document Name
07/21/2020 Letter Permit Application
07/21/2020 Letter License Tax Application
07/21/2020 MO88 - Air Combustion
07/22/2020 Letter Codes Residential Plan Review
07/23/2020 Drawing Approved Drawings
07/23/2020 Plot Plan Approved Plot Plan
07/31/2020 Receipt Receipt for transaction:2020-004890
07/31/2020 Letter DS Building Permit
08/07/2020 M L Crose 1116 NE Goshen Ct LSMO Monticello 3rd Party Footing Inspection Report 8-7-20
08/19/2020 Letter INSPECTION SUMMARY
08/19/2020 Letter INSPECTION SUMMARY
08/27/2020 Letter INSPECTION SUMMARY
09/25/2020 Letter INSPECTION SUMMARY
09/25/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
11/24/2020 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
02/05/2021 Letter INSPECTION SUMMARY
02/05/2021 Letter INSPECTION SUMMARY
02/23/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter Codes Temporary Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home