Permit Application Status

PRRES20201611


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201611
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY FINISHED BASEMENT COVERED DECK CLOSED WITH OPEN VIOLATIONS OR EXCEEDED PERMIT LIMITS
06/15/2020
06/29/2020
02/27/2024
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
KEVIN@HIGDONBUILDERS.COM  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/25/2020 06/25/2020
Steve Conrick
Residential Plan Review Approved 06/25/2020 06/25/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,072.13 $1,072.13 Paid 06/29/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/29/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/29/2020
8331504-EFHB Middle Big Creek, Full $602.64 $602.64 Paid 06/29/2020
8331507-Sewer Connection Fee $540.00 $540.00 Paid 06/29/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 06/29/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 06/29/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/15/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/7/2020 (2:30) 7/7/2020 07/07/2020
Underslab Plumbing Inspection - Residential Not Ready 8/10/2020 8/10/2020 08/10/2020
Misc
Corrective Action Required
08/10/2020
INSPECTION DENIED - NO SILT FENCE FOR EROSION CONTROL ON LOT, INSTALL EROSION CONTROL BEFORE RESCHEDULING INSPECTION -
Erosion Control Inspection Residential Failed 08/10/2020
Misc
Corrective Action Required
08/10/2020
- NO SILT FENCE FOR EROSION CONTROL ON LOT, INSTALL EROSION CONTROL BEFORE RESCHEDULING INSPECTION -
Underslab Plumbing Inspection - Residential Failed 8/13/2020 8/13/2020 08/13/2020
Misc
Corrective Action Required
08/10/2020
- INTERIOR DRAIN TILE COVERED WITH GRAVEL, NO VISIBLE SUMP PIT, UNCOVER ALL INTERIOR DRAIN TILE FOR INSPECTION - SHOWER COVER OFF ON DWV
Underslab Plumbing Inspection - Residential Passed 8/20/2020 8/20/2020 08/20/2020
Misc
Resolved
08/20/2020
Sewer Service Inspection - R Passed 11/3/2020 (9:30) 11/3/2020 11/03/2020
Water Service Inspection - R Partial 11/5/2020 (8:15) 11/5/2020 11/05/2020
Misc
Informational
11/05/2020
- PARTIAL INSPECTION ON PEX ENTRANCE TO HOUSE AND MID POINT RUN TO YARD. OK TO COVER PORTION INSPECTED
Water Service Inspection - R Passed 11/5/2020 11/5/2020 11/05/2020
Misc
Resolved
11/05/2020
- PARTIAL INSPECTION ON PEX ENTRANCE TO HOUSE AND MID POINT RUN TO YARD. OK TO COVER PORTION INSPECTED
Piers/Caissons Inspection - Residential Passed 12/29/2020
Electrical Service Inspection Passed 12/29/2020 12/29/2020 12/29/2020
Gas Service Inspection - Residential Passed 12/29/2020 12/29/2020 12/29/2020
Gas Piping Inspection - Residential Failed 12/29/2020 12/29/2020
Misc
Corrective Action Required
12/29/2020
-SECURE WARD FLEX AT FIREPLACES
All Rough Inspection - Residential Failed 12/29/2020 12/29/2020 12/29/2020
Misc
Corrective Action Required
12/29/2020
-Seal top and bottom plate penetrations -see garage, living room, front entry bath,laundry -Secure all DWV 2” or less at mid point -Install exterior doors -Structural straps at all top plates bored 50% or more on all exterior walls and all interior load bearing walls -Fireblock at fireplace lid between studs -Secure ward flex at fireplace(s) -Nail king studs to headers -security blocking back door -protect NM (romex) 6” AFF at kitchen island -No roof support per plans at (3) lvl kitchen/living room -12” oc nailing at all abutting and intersecting wall corners (braced wall panels) -Holes bored in floor joists for NM less than 2” from end of member, several locations throughout basement -Seal penetrations at basement fireplace -Complete bath exhaust discharge, basement bath -Fireblock vertical to horizontal at furred downs in basement -Fireblock vertical every 10’ between foundation wall and framing -seal gaps in Fireblock -NE Basement bath floor joist bored for pex and DWV less than 2” from end of joist and less than 2” apart -GEC ufer connection in basement bathroom must remain accessible -seal all penetrations through air returns and plenums -(2) bolts at deck post/rim connection -bolt rim to ledger and add angel clip on interior ply at deck
All Rough Inspection - Residential Failed 1/20/2021 1/20/2021 01/20/2021
Misc
Corrective Action Required
01/20/2021
-Seal top and bottom plate penetrations - front entry hall bath -Holes bored in floor joists for NM less than 2” from end of member, several locations throughout basement -NE Basement bath floor joist bored for pex and DWV less than 2” from end of joist and less than 2” apart OK TO INSULATE - REMOVE INSULATION FROM ANY INSPECTION ITEMS
All Rough Inspection - Residential Failed 1/28/2021 1/28/2021 01/28/2021
Misc
Corrective Action Required
01/20/2021
****ALL DOORS TO HOUSE LOCKED AND NO LOCK BOX CODE PROVIDED**** -Seal top and bottom plate penetrations - front entry hall bath -Holes bored in floor joists for NM less than 2” from end of member, several locations throughout basement -NE Basement bath floor joist bored for pex and DWV less than 2” from end of joist and less than 2” apart OK TO INSULATE - REMOVE INSULATION FROM ANY INSPECTION ITEMS
All Rough Inspection - Residential Passed 1/29/2021 1/29/2021 01/29/2021
Misc
Resolved
01/29/2021
Gas Piping Inspection - Residential Passed 01/29/2021
Misc
Resolved
01/29/2021
Driveway Inspection Partial 3/22/2021 3/22/2021 03/22/2021
Misc
Informational
03/22/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate
Sidewalk Inspection Partial 3/22/2021 3/22/2021 03/22/2021
Misc
Informational
03/22/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate
Driveway Inspection Passed 3/29/2021 3/29/2021 03/30/2021
Misc
Informational
03/22/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate
Sidewalk Inspection Passed 3/29/2021 3/29/2021 03/30/2021
Misc
Informational
03/22/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate
Occupancy Inspection - Codes Residential Failed 6/15/2021 6/15/2021 06/15/2021
Misc
Corrective Action Required
06/15/2021
-Obtain lawn irrigation system permit -Resolve outstanding inspection fees before final c of o -splash blocks at all downspout and sump pump discharge locations, min 36” discharge from foundation -seal penetrations in siding, seal along top of AC disconnect and meter can -Security screws at deck door and basement walkout, (2) 3” screws at each hinge and strike plate -Kitchen counter receptacles, Max 1/4” setback at box on non combustible surfaces, box not sealed flush with faceplate on uneven tile surface -Nail all joist hangers and hold downs at deck -(2) 1/2” through bolts at each post beam connection per code
Erosion Control Inspection Residential Passed 06/17/2021
Misc
Resolved
06/17/2021
- NO SILT FENCE FOR EROSION CONTROL ON LOT, INSTALL EROSION CONTROL BEFORE RESCHEDULING INSPECTION -
Plot Plan Inspection Passed 06/17/2021
Occupancy Inspection - Codes Residential Temporary C of O 6/17/2021 6/17/2021 06/17/2021
Misc
Corrective Action Required
06/15/2021
**TCO UNTIL 7-2-21 -(2) 1/2” through bolts at each post beam connection per code
Documents & Images
Date Uploaded File Type Document Name
06/15/2020 Copy of Lees Summit Residental Permit Application 1713 blackstone lot 144
06/22/2020 LOT 144 FINAL
06/22/2020 KH-6107 (WHITE TAIL) LOT 144 (00000004)
06/25/2020 APPROVED KH-6107 (WHITE TAIL) LOT 144 (00000004)
06/25/2020 APPROVED LOT 144 FINAL
06/29/2020 exciseapplication
06/29/2020 Receipt Receipt for transaction:2020-003772
06/29/2020 Letter DS Building Permit
07/07/2020 Letter INSPECTION SUMMARY
08/10/2020 Letter INSPECTION SUMMARY
08/10/2020 Letter INSPECTION SUMMARY
08/13/2020 Letter INSPECTION SUMMARY
08/17/2020 Engineer Report/Study Final_2020.08.11_DPier_LSMO_Concrete Design
08/20/2020 Letter INSPECTION SUMMARY
11/03/2020 Letter INSPECTION SUMMARY
11/05/2020 Letter INSPECTION SUMMARY
11/05/2020 Letter INSPECTION SUMMARY
12/29/2020 Letter INSPECTION SUMMARY
12/29/2020 Letter INSPECTION SUMMARY
12/29/2020 Letter INSPECTION SUMMARY
12/29/2020 Letter INSPECTION SUMMARY
12/29/2020 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/27/2021 1713 Blackstone
01/28/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
06/15/2021 Letter INSPECTION SUMMARY
06/15/2021 Receipt Receipt for transaction:2021-004471
06/17/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter Codes Temporary Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: