Permit Application Status

PRRES20201148


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201148
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY PARTIALLY FINISHED BASEMENT COVERED DECK
05/06/2020
05/18/2020
11/09/2020
04/01/2021
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
FIRST CHOICE CUSTOM HOMES LLC, Address:PO BOX 860072, Phone:(913) 449-8935  
fcchllc@yahoo.com  
ADVANCED ELECTRICAL LLC, Address:PO BOX 1573, Phone:(816) 347-8187  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK ST, Phone:(913) 829-8213  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/20/2020 05/18/2020
Steve Conrick
Spot elevations
Corrective Action Required
05/18/2020

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. PROVIDE CROSS SECTION ELEVATIONS WITHIN SWALE
As-graded plot plan
Corrective Action Required
05/18/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
BUILDER ONLY SUBMITTED PLOT PLAN Steven Conrick 05/08/2020 3:47 PM
Residential Plan Review Approved 05/20/2020 05/18/2020
Steve Conrick
Plot Plan Review Rejected 05/13/2020 05/13/2020
Steve Conrick
Spot elevations
Corrective Action Required
05/13/2020

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. PROVIDE CROSS SECTION ELEVATIONS WITHIN SWALE
As-graded plot plan
Corrective Action Required
05/13/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
BUILDER ONLY SUBMITTED PLOT PLAN Steven Conrick 05/08/2020 3:47 PM
Residential Plan Review Approved 05/13/2020 05/13/2020
Steve Conrick
BUILDER ONLY SUBMITTED PLOT PLAN Steven Conrick 05/08/2020 3:47 PM
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $965.74 $965.74 Paid 05/18/2020
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 05/18/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 05/18/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 05/18/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 05/18/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/18/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/18/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/9/2020 (3:00) 6/9/2020 06/09/2020
Underslab Plumbing Inspection - Residential Passed 7/6/2020 7/6/2020 07/06/2020
Miscellaneous Inspection Passed 7/28/2020 7/28/2020 07/28/2020
Misc
Informational
07/28/2020
- Inspected garage portal
Sewer Service Inspection - R Passed 8/14/2020 (10:30) 8/14/2020 08/14/2020
Piers/Caissons Inspection - Residential Passed 8/14/2020 8/14/2020 08/14/2020
Water Service Inspection - R Passed 8/17/2020 (9:30) 8/17/2020 08/17/2020
Electrical Service Inspection Passed 9/28/2020 9/28/2020 09/28/2020
Gas Piping Inspection - Residential Failed 9/28/2020 9/28/2020 09/28/2020
Misc
Corrective Action Required
09/28/2020
-secure ward flex at fireplace
Gas Service Inspection - Residential Passed 9/28/2020 9/28/2020 09/28/2020
All Rough Inspection - Residential Failed 9/28/2020 9/28/2020 09/28/2020
Misc
Corrective Action Required
09/28/2020
-Maintain silt fence along front of lot, clean silt at storm sewer entrance, maintain a gravel filter on lot, correct issues before rescheduling any inspections -Structural straps required at top plate, all exterior walls and interior load bearing walls bored 50% or more -secure ward flex at fireplace -Provide proper fall for DWV vent -Support DWV every 48” o.c., traps not considered support -Joist hangers required for ceiling joists in master water closet, master shower, over 4’ -2x4 laid flat furred downs 3’ or more in basement must be supported to the floor joists to support the ceiling load -Security blocking at basement door -protection plate at DWV basement bath top plate -pan off bottom cantilever in garage
Erosion Control Inspection Residential Failed 9/28/2020 9/28/2020 09/28/2020
Misc
Corrective Action Required
09/28/2020
-Maintain silt fence along front of lot, clean silt at storm sewer entrance, maintain a gravel filter on lot, correct issues before rescheduling any inspections
Gas Piping Inspection - Residential Passed 10/1/2020 10/1/2020 10/01/2020
Misc
Resolved
10/01/2020
All Rough Inspection - Residential Failed 8/14/2020 10/1/2020 10/01/2020
Misc
Corrective Action Required
10/01/2020
-Security blocking at basement door -Pan off bottom cantilever in garage - entry closet
All Rough Inspection - Residential Passed 10/2/2020 10/2/2020 10/02/2020
Misc
Resolved
10/02/2020
Driveway Inspection Partial 12/2/2020 (P.M.) 12/2/2020 12/02/2020
Misc
Informational
12/02/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 12/9/2020 12/9/2020 12/09/2020
Misc
Informational
12/02/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Erosion Control Inspection Residential Failed 1/13/2021 1/13/2021 01/13/2021
Misc
Resolved
01/13/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/13/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN SILT FENCE ON LOT, SILT FENCE REQUIRED AT FRONT OF LOT, MAINTAIN GUTTER BUDDIES AT STREET STORM INLETS AND REMOVE COLLECTED SILT -SILT FENCE REQUIRED AT BACK OF LOT, SILT FENCE CURRENTLY DOWN ALLOWING SILT TO FLOW INTO STORM INLET AT SWALE AT BACK OF LOT
Occupancy Inspection - Codes Residential Failed 3/16/2021 3/16/2021 03/16/2021
Misc
Corrective Action Required
03/16/2021
-Final grade and sod -Provide gutters, downspouts, splash blocks, and sump discharge extension -GFCI at front door doesn't reset -Provide non combustible attic access cover -Provide handrail for garage entry stairs over 4 rises -Provide GFCI protection at dishwasher and washing machine -Provide Hammer arrestors at kitchen sink and washing machine -Provide (2) 3" security screws per hinge and strike plate at exterior doors -Secure whip at AC -Lower drain to grade inside of window well
Occupancy Inspection - Codes Residential Temporary C of O 3/23/2021 3/23/2021 03/23/2021
Misc
Corrective Action Required
03/16/2021
-Maintain erosion control on lot until sod is placed -Final grade and sod -Provide splash blocks and sump discharge extension, minimum 36" discharge from foundation -Lower drain to grade inside of window well OK FOR TCO - TCO EXPIRES 4/9/21
Plot Plan Inspection Passed 3/26/2021 03/26/2021
Occupancy Inspection - Codes Residential Full C of O 4/2/2021 4/2/2021 04/01/2021
Misc
Resolved
04/01/2021
Documents & Images
Date Uploaded File Type Document Name
05/06/2020 Lees Summit Permit Application - 1610 SW Blackstone
05/08/2020 1610 SW Blackstone Pl LSMO_Preliminary HERS Certificate
05/08/2020 Lees Summit Permit Application - 1610 SW Blackstone
05/08/2020 Lees Summit Excise Tax
05/08/2020 Napa Valley 3rd Lot 127 20.0504
05/08/2020 Napa Valley 3rd Lot 127 20.0504
05/08/2020 DW 39134
05/13/2020 APPROVED DW 39134
05/13/2020 Letter Codes Residential Plan Review
05/18/2020 Napa Valley 3rd Lot 127 20.0515
05/18/2020 APPROVED Napa Valley 3rd Lot 127 20.0515
05/18/2020 Receipt Receipt for transaction:2020-002197
05/18/2020 Letter DS Building Permit
06/09/2020 Letter INSPECTION SUMMARY
06/09/2020 Engineer Report/Study 1610 SW BLACKSTONE PL SOIL
07/06/2020 Letter INSPECTION SUMMARY
07/28/2020 Letter INSPECTION SUMMARY
08/14/2020 Letter INSPECTION SUMMARY
08/14/2020 Letter INSPECTION SUMMARY
08/17/2020 Letter INSPECTION SUMMARY
09/28/2020 Letter INSPECTION SUMMARY
09/28/2020 Letter INSPECTION SUMMARY
09/28/2020 Letter INSPECTION SUMMARY
09/28/2020 Letter INSPECTION SUMMARY
09/28/2020 Letter INSPECTION SUMMARY
10/01/2020 Letter INSPECTION SUMMARY
10/01/2020 Letter INSPECTION SUMMARY
10/02/2020 Letter INSPECTION SUMMARY
12/02/2020 Letter INSPECTION SUMMARY
12/09/2020 Letter INSPECTION SUMMARY
01/13/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/23/2021 Letter Codes Temporary Certificate of Occupancy
03/24/2021 Napa Valley 3rd Lot 127 FG 21_0322
03/25/2021 Plot Plan Approved As Graded Plot Plan
03/26/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter Field Certificate of Occupancy
04/01/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home