Permit Application Status

PRRES20193316


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193316
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - PARTIAL FINISHED BASEMENT
11/08/2019
01/16/2020
09/08/2020
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
KEVIN@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 12/12/2019 01/16/2020
Development Center
Miscellaneous Correction
Corrective Action Required
12/10/2019

Please label all exterior materials
Plot Plan Review Approved 11/12/2019 01/10/2020
Dylan Eppert
Sidewalks
Corrective Action Required
11/11/2019

Sidewalks with dimensions must be provided on the plot plan. NO SIDEWALK SHOWN ON PLAT PLEASE CLARIFY.
Drainage swales
Corrective Action Required
11/11/2019

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide
As-graded plot plan
Corrective Action Required
11/11/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Basement egress
Corrective Action Required
11/11/2019

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. Construction Drawings must be the same layout as the plot plan. They appear flipped. please correct this.
Miscellaneous Correction
Corrective Action Required
11/11/2019

Add 100 year flood elevation detail.
Basement elevation
Corrective Action Required
11/11/2019

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) MDP SHOWS STANDARD BASEMENT AND YOUR PURPOSING A DAYLIGHT. PLEASE ADD
Residential Plan Review Approved 11/12/2019 12/23/2019
Dylan Eppert
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
11/11/2019

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) 1ST FLOOR SQ FT IS DIFFERENT PLEASE CLARIFY FINISHED BASEMENT SQ FT IS OFF PLEASE CLARIFY UNFINISHED BASEMENT SQ FT IS OFF PLEASE CLARIFY GARAGE SQ FT IS OFF PLEASE CLARIFY.
11 Designate R-value(s) for floors, walls, ceilings, roof/ceilings.
Corrective Action Required
11/11/2019

Designate R-value(s) for floors, walls, ceilings, roof/ceilings. (LSCO 7-802) INSULATION DETAIL REFERS TO 2012 IRC AND SHOULD REFERENCE 2018.
Miscellaneous Correction
Corrective Action Required
11/11/2019

ALL NOTES SHOULD REFERENCE 2018 IRC BUILDING CODE NOT 2012.
Planning Review (RES) Rejected 11/13/2019 12/10/2019
Victoria Nelson
Miscellaneous Correction
Corrective Action Required
12/10/2019

Please label all exterior materials
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $971.38 $971.38 Paid 01/16/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 01/16/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 01/16/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 01/16/2020
8331504-EFHB Middle Big Creek, Half $217.62 $217.62 Paid 01/16/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/16/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/16/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/16/2020 1/16/2020 01/16/2020
Underslab Plumbing Inspection - Residential Failed 2/12/2020 2/12/2020 02/12/2020
Misc
Corrective Action Required
02/12/2020
- Post address - Unable to perform inspection due to snow, mud, water covering DWV. Please reschedule inspection when condition allow for a complete inspection.
Underslab Plumbing Inspection - Residential Passed 2/24/2020 2/24/2020 02/24/2020
Misc
Resolved
02/24/2020
- Post address -
Erosion Control Inspection Residential Failed 4/7/2020 04/07/2020
Misc
Corrective Action Required
04/07/2020
Failing erosion control is causing silt to fill in the swale behing the lot. Please take a look and make corrections.
Gas Service Inspection - Residential Failed 4/13/2020 4/13/2020 04/13/2020
Misc
Corrective Action Required
04/13/2020
- secure gas line at fireplace - - provide bond gas line - - pressure steady at 14 psi -
Gas Piping Inspection - Residential Passed 4/16/2020 4/16/2020 04/16/2020
Gas Service Inspection - Residential Failed 4/16/2020 04/16/2020
Misc
Corrective Action Required
04/13/2020
- provide bond gas line -
Erosion Control Inspection Residential Failed 4/24/2020 04/24/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/24/2020
_ MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER -
Electrical Service Inspection Passed 4/24/2020 4/24/2020 04/24/2020
All Rough Inspection - Residential Failed 4/24/2020 4/24/2020 04/24/2020
Misc
Corrective Action Required
04/24/2020
- provide anchor bolts within 12” of plate break family room basement - - tighten anchor bolts & provide nuts & washers basement - - address rafters landing on blocks - - valley strut in garage more than 45 degrees -
Gas Service Inspection - Residential Passed 4/24/2020 4/24/2020 04/24/2020
Misc
Resolved
04/24/2020
All Rough Inspection - Residential Passed 4/29/2020 4/29/2020 04/29/2020
Misc
Informational
04/29/2020
- Engineer letter received concerning approved use of blocks at rafters 4/28/20 Kurt Krasick 2016001265 -
Sewer Service Inspection - R Partial 5/1/2020 5/1/2020 at 2:00 PM 05/01/2020
Misc
Informational
05/01/2020
- 20' sewer from house to middle of yard -
Sewer Service Inspection - R Passed 5/7/2020 (9:15) 5/7/2020 05/07/2020
Misc
Informational
05/01/2020
Water Service Inspection - R Passed 5/7/2020 5/7/2020 05/07/2020
Piers/Caissons Inspection - Residential Passed 5/13/2020 (8:30) 5/13/2020 05/13/2020
Misc
Corrective Action Required
05/13/2020
(3) 24 X 36 DECK PIERS
Driveway Inspection Partial 06/17/2020
Misc
Informational
06/17/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 6/24/2020 6/24/2020 06/25/2020
Misc
Informational
06/17/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 8/20/2020 8/20/2020 08/20/2020
Misc
Corrective Action Required
08/20/2020
- Submit as graded plot plan for review - Obtain lawn irrigation system permit - Complete guardrail and handrail at deck - Solid block between deck stair rises - Dbl joist hanger at deck floor joist and dbl hoist hanger at cantilever header, both over 4’ in length
Occupancy Inspection - Codes Residential Temporary C of O 8/21/2020 8/21/2020 08/21/2020
Misc
Corrective Action Required
08/20/2020
- Submit as graded plot plan for review - Obtain lawn irrigation system permit OK for TCO
Plot Plan Inspection Passed 9/8/2020 09/08/2020
Misc
Resolved
09/08/2020
Occupancy Inspection - Codes Residential Full C of O 09/08/2020
Misc
Resolved
09/08/2020
Documents & Images
Date Uploaded File Type Document Name
12/10/2019 Letter Codes Residential Plan Review
12/30/2019 Letter Codes Residential Plan Review
01/16/2020 Receipt Receipt for transaction: 2020-000198
01/16/2020 Letter DS Building Permit
01/16/2020 Letter INSPECTION SUMMARY
01/16/2020 Letter DS Building Permit
01/17/2020 Plot Plan DOC011720-01172020101523
02/12/2020 Letter INSPECTION SUMMARY
02/24/2020 Letter INSPECTION SUMMARY
04/07/2020 Letter DE-Daily Inspection Summary
04/13/2020 Letter INSPECTION SUMMARY
04/16/2020 Letter INSPECTION SUMMARY
04/16/2020 Letter INSPECTION SUMMARY
04/24/2020 Letter INSPECTION SUMMARY
04/24/2020 Letter INSPECTION SUMMARY
04/24/2020 Letter INSPECTION SUMMARY
04/24/2020 Letter INSPECTION SUMMARY
04/28/2020 Engineer Report/Study 1626 Blackstone
04/29/2020 Letter INSPECTION SUMMARY
05/01/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter DE-Daily Inspection Summary
05/07/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
06/25/2020 Letter INSPECTION SUMMARY
08/20/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter Codes Temporary Certificate of Occupancy
09/04/2020 Plot Plan APPROVED AS-BUILT
09/08/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter Field Certificate of Occupancy
09/08/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home