Summary
PRRES20192817
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO
09/30/2019
11/01/2019
07/06/2020
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
PERMITTING@JFECONSTRUCTION.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 10/02/2019 10/16/2019
Kim Brennan
10 Combustion air
Corrective Action Required
09/30/2019

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
10/01/2019

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10) No braced wall locations or length shown on the upper level
Plot Plan Review Approved 10/02/2019 10/16/2019
Kim Brennan
North arrow and scale
Corrective Action Required
10/01/2019

The plot plan must be submitted on either (1) 81/2” x 11”, (2) 81/2”x 14”, or (3) 11” x 17” paper. All information on the plot plan must be drawn to scale. Scale must be 1” = 10’, 20’, or 30’; smaller scales that are multiples of the preceding scales may be used if necessary to represent large sites. All information on the plot plan must be clearly legible.) Plot plan must be drawn to scale
Basement opening elevations
Corrective Action Required
10/01/2019

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
City infrustructure
Corrective Action Required
10/01/2019

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. Please show location of fire hydrant
As-graded plot plan
Corrective Action Required
10/01/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,500.89 $1,500.89 Paid 11/01/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/01/2019
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/01/2019
8331507-Sewer Connection Fee $630.00 $630.00 Paid 11/01/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 11/01/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 11/01/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 11/15/2019 11/15/2019 11/15/2019
Misc
Corrective Action Required
11/15/2019
No access, backfill or provide access to perform inspection
Sewer Service Inspection - R Passed 11/15/2019 (11:15) 11/15/2019 11/15/2019
Water Service Inspection - R Partial 11/15/2019 (11:15) 11/15/2019 11/15/2019
Water Service Inspection - R Passed 11/18/2019 (9:15) 11/18/2019 11/18/2019
Underslab Plumbing Inspection - Residential Passed 11/25/2019 11/25/2019 11/25/2019
Misc
Resolved
11/25/2019
Erosion Control Inspection Residential Failed 2/26/2020 02/26/2020
Misc
Corrective Action Required
02/26/2020
Maintain silt fence - Maintain gravel filter -
Gas Piping Inspection - Residential Passed 2/26/2020 02/26/2020
Gas Service Inspection - Residential Passed 2/26/2020 2/26/2020 02/26/2020
All Rough Inspection - Residential Failed 2/26/2020 2/26/2020 02/26/2020
Misc
Corrective Action Required
02/26/2020
No footing inspection on record- No pier inspection on record- Provide min one 5/8 anchor bolt per plan PFH portal frame garage - Address rafters landing on multiple blocks throughout house - Provide insulation at cantilever living room complete soffit & trim horizontal flashing if required - Provide shield master shower rain head pex within 12” of can light - Provide solid security blocking patio door -
Electrical Service Inspection Passed 2/26/2020 2/26/2020 02/27/2020
Misc
Resolved
02/27/2020
Misc
Resolved
02/27/2020
All Rough Inspection - Residential Passed 3/4/2020 3/4/2020 at 3:50 PM 03/04/2020
Misc
Resolved
03/04/2020
- Provide insulation at cantilever living room complete soffit & trim horizontal flashing if required - Provide shield master shower rain head pex within 12” of can light - Provide solid security blocking patio door -
Driveway Inspection Partial 4/27/2020 (P.M.) 4/27/2020 04/27/2020
Misc
Informational
04/27/2020
Forms were placed and aggregate was present and compacted. They will be using KCMMB mix and white cure. RP 4-27-20
Sidewalk Inspection Partial 4/27/2020 (P.M.) 4/27/2020 04/27/2020
Misc
Informational
04/27/2020
Forms were placed and aggregate was present and compacted. They will be using KCMMB mix and white cure. They have been informed to broom finish the sidewalk, not picture framed. RP 4-27-20
Driveway Inspection Passed 5/7/2020 05/07/2020
Misc
Informational
05/07/2020
Finished driveway meets LS and ADA specs. RP 5-7-20
Sidewalk Inspection Passed 5/7/2020 05/07/2020
Misc
Informational
04/27/2020
Forms were placed and aggregate was present and compacted. They will be using KCMMB mix and white cure. They have been informed to broom finish the sidewalk, not picture framed. RP 4-27-20
Misc
Informational
05/07/2020
Finished sidewalk meets LS and ADA specs. RP 5-7-20
Footing Inspection - Residential Passed 11/4/2019 06/05/2020
Misc
Informational
06/05/2020
- FOUNDATION ONLY PERMIT 20193098 -
Piers/Caissons Inspection - Residential Passed 2/28/2020 06/05/2020
Misc
Informational
06/05/2020
- 3RD PARTY BY APEX ON FILE -
Plot Plan Inspection Passed 6/5/2020 06/05/2020
Occupancy Inspection - Codes Residential Failed 6/9/2020 6/9/2020 06/09/2020
Misc
Corrective Action Required
06/09/2020
- PROVIDE FINAL GRADE, SOD, SPLASH BLOCKS -
Occupancy Inspection - Codes Residential Temporary C of O 6/15/2020 6/15/2020 06/15/2020
Misc
Corrective Action Required
06/15/2020
- PROVIDE FINAL GRADE, SOD, SPLASH BLOCKS -
Occupancy Inspection - Codes Residential Full C of O 7/6/2020 7/6/2020 07/06/2020
Misc
Resolved
07/06/2020
Deck Final Inspection - Residential Passed 7/6/2020 07/06/2020
Documents & Images
Date Uploaded File Type Document Name
10/01/2019 Letter Codes Residential Plan Review
11/01/2019 Receipt Receipt for transaction: 2019-007120
11/01/2019 Letter DS Building Permit
11/01/2019 Plot Plan DOC110119
11/15/2019 Letter INSPECTION SUMMARY
11/15/2019 Letter INSPECTION SUMMARY
11/15/2019 Letter INSPECTION SUMMARY
11/18/2019 Letter INSPECTION SUMMARY
11/25/2019 Letter INSPECTION SUMMARY
02/26/2020 Letter INSPECTION SUMMARY
02/26/2020 Letter INSPECTION SUMMARY
02/26/2020 Letter INSPECTION SUMMARY
02/26/2020 Letter INSPECTION SUMMARY
02/27/2020 Letter INSPECTION SUMMARY
02/27/2020 Letter INSPECTION SUMMARY
02/28/2020 Engineer Report/Study 121 NW McKenzie Drive_Framing Evaluation Report_2-27-20
03/02/2020 Engineer Report/Study 121 NW Mackenzie Dr_Lot 1465 Winterset Valley Final_2020.02.28_PostPour GBSlab DPIer_LSMO_Concrete Design
03/04/2020 Letter INSPECTION SUMMARY
04/27/2020 Letter INSPECTION SUMMARY
04/27/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
06/04/2020 Plot Plan As Graded Plot Plan
06/05/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter Codes Temporary Certificate of Occupancy
07/06/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home