Permit Application Status

PRRES20192062


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20192062
Building Permit - Residential
Certificate of Occupancy
KEVIN HIGDON CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
07/31/2019
08/06/2019
05/26/2020
Locations
Contacts
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
HIGGINBOTHAM.BRIAN@YAHOO.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 08/02/2019 08/06/2019
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
07/31/2019

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) no egress shown from the unfinished basement
Plot Plan Review Approved 08/02/2019 08/06/2019
Steve Conrick
Legal description
Corrective Action Required
07/31/2019

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. The address on the plot plan is incorrect. It should be 4020 SW Meritage Ln
Sidewalks
Corrective Action Required
07/31/2019

Sidewalks with dimensions must be provided on the plot plan.
City infrustructure
Corrective Action Required
07/31/2019

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. Fire hydrant is not shown on the plot plan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,496.38 $1,496.38 Paid 08/06/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/06/2019
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 08/06/2019
8331504-EFHB Middle Big Creek, Full $636.12 $636.12 Paid 08/06/2019
8331507-Sewer Connection Fee $570.00 $570.00 Paid 08/06/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 08/06/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 08/06/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/16/2019 8/16/2019 08/16/2019
Underslab Plumbing Inspection - Residential Passed 9/24/2019 9/24/2019 09/24/2019
Piers/Caissons Inspection - Residential Passed 10/15/2019 (2:00) 10/15/2019 10/15/2019
Sewer Service Inspection - R Passed 12/2/2019 (3:00) 12/2/2019 12/02/2019
Water Service Inspection - R Passed 12/10/2019 12/10/2019 12/10/2019
Electrical Service Inspection Passed 12/18/2019 12/18/2019 12/18/2019
Gas Service Inspection - Residential Failed 12/18/2019 12/18/2019 12/18/2019
Misc
Corrective Action Required
12/18/2019
Not enough PSI in pressure gauge
All Rough Inspection - Residential Failed 12/18/2019 12/18/2019 12/18/2019
Misc
Corrective Action Required
12/18/2019
- Install proper hold down washers and bolts. Bolts need to be within middle third of plate - protect electrical at bottom plate in pantry - secure gas line to all fire places - fire place in master bedroom needs to be fire blocked above - fire block gas line going through sub floor in front of fire place - need additional support for valley above master bedroom and bedroom to the south - fireblock below master bathroom tub - collar ties need to be installed - joist hangers needed for second floor stair landing - anchor beam posts in basement - no psi in pressure gauge - address cut floor joist for duct work on north side of furnace - stair stringers going to basement have been cut short, need to be properly bearing - address needs to be posted Do not insulate
Erosion Control Inspection Residential Failed 12/18/2019 12/18/2019
Misc
Corrective Action Required
12/18/2019
Install and fix proper erosion control before any future inspections
All Rough Inspection - Residential Failed 12/26/2019 12/26/2019 12/26/2019
Misc
Corrective Action Required
12/18/2019
- Install proper hold down washers and bolts. Bolts need to be within middle third of plate - protect electrical at bottom plate in pantry - secure gas line to all fire places - fire place in master bedroom needs to be fire blocked above - fire block gas line going through sub floor in front of fire place - need additional support for valley above master bedroom and bedroom to the south - fireblock below master bathroom tub - collar ties need to be installed - joist hangers needed for second floor stair landing - anchor beam posts in basement - no psi in pressure gauge - address cut floor joist for duct work on north side of furnace - stair stringers going to basement have been cut short, need to be properly bearing - address needs to be posted Do not insulate No inspection performed, fix erosion control before future inspections
Gas Service Inspection - Residential Failed 12/26/2019 12/26/2019 12/26/2019
Misc
Corrective Action Required
12/18/2019
Not enough PSI in pressure gauge
Erosion Control Inspection Residential Failed 12/26/2019
Misc
Corrective Action Required
12/18/2019
Install and fix proper erosion control before any future inspections
All Rough Inspection - Residential Failed 12/27/2019 12/27/2019 12/27/2019
Misc
Corrective Action Required
12/26/2019
- secure gas line to all fire places - fire place in master bedroom needs to be fire blocked above - need 10 psi in pressure gauge - address needs to be posted Ok to insulate
Gas Service Inspection - Residential Failed 12/27/2019 12/27/2019 12/27/2019
Misc
Corrective Action Required
12/26/2019
Not enough PSI in pressure gauge, need 10 psi for 15 minutes minimum
All Rough Inspection - Residential Passed 12/31/2019 12/31/2019
Misc
Informational
12/31/2019
- address needs to be posted Ok to insulate
Gas Service Inspection - Residential Passed 12/31/2019 12/31/2019 12/31/2019
Misc
Resolved
12/31/2019
Sidewalk Inspection Partial 2/18/2020 2/18/2020 02/18/2020
Misc
Informational
02/18/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 2/25/2020 02/28/2020
Misc
Informational
02/18/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 3/3/2020 (A.M.) 3/3/2020 03/03/2020
Misc
Informational
03/03/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Partial 03/03/2020
Misc
Informational
03/03/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 3/9/2020 03/10/2020
Misc
Informational
03/03/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 3/9/2020 03/10/2020
Misc
Informational
03/03/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Erosion Control Inspection Residential Failed 3/24/2020 03/24/2020
Misc
Corrective Action Required
12/26/2019
Install and fix proper erosion control before any future inspections
Occupancy Inspection - Codes Residential Failed 3/24/2020 3/24/2020 03/24/2020
Misc
Corrective Action Required
03/24/2020
Final grade sod, splash blocks, check all exterior.
Occupancy Inspection - Codes Residential Temporary C of O 3/26/2020 3/26/2020 03/26/2020
Misc
Corrective Action Required
03/24/2020
Install anti siphon basement hose bib. Secure wardflex at furnaces. Establish erosion control before next inspection. Final grade sod, splash blocks, check all exterior.
Plot Plan Inspection Passed 5/11/2020 05/11/2020
Occupancy Inspection - Codes Residential Failed 5/11/2020 5/11/2020 05/11/2020
Misc
Resolved
05/11/2020
Misc
Corrective Action Required
05/11/2020
- PROVIDE IRRIGATION PERMIT -
Occupancy Inspection - Codes Residential Full C of O 5/26/2020 5/26/2020 05/26/2020
Misc
Resolved
05/26/2020
Documents & Images
Date Uploaded File Type Document Name
07/31/2019 Letter Codes Residential Plan Review
08/05/2019 Letter Codes Residential Plan Review
08/06/2019 Receipt Receipt for transaction: 2019-005351
08/06/2019 Letter DS Building Permit
08/06/2019 Plot Plan DOC080619
08/16/2019 Letter INSPECTION SUMMARY
09/24/2019 Letter INSPECTION SUMMARY
10/15/2019 Letter INSPECTION SUMMARY
12/02/2019 Letter INSPECTION SUMMARY
12/10/2019 Letter INSPECTION SUMMARY
12/18/2019 Letter INSPECTION SUMMARY
12/18/2019 Letter INSPECTION SUMMARY
12/18/2019 Letter INSPECTION SUMMARY
12/18/2019 Letter INSPECTION SUMMARY
12/26/2019 Letter INSPECTION SUMMARY
12/26/2019 Letter INSPECTION SUMMARY
12/26/2019 Letter INSPECTION SUMMARY
12/26/2019 Letter INSPECTION SUMMARY
12/27/2019 Letter INSPECTION SUMMARY
12/27/2019 Letter INSPECTION SUMMARY
12/31/2019 Letter INSPECTION SUMMARY
12/31/2019 Letter INSPECTION SUMMARY
02/18/2020 Letter INSPECTION SUMMARY
02/28/2020 Letter INSPECTION SUMMARY
03/03/2020 Letter INSPECTION SUMMARY
03/03/2020 Letter INSPECTION SUMMARY
03/10/2020 Letter INSPECTION SUMMARY
03/10/2020 Letter INSPECTION SUMMARY
03/24/2020 Letter INSPECTION SUMMARY
03/26/2020 Letter Codes Temporary Certificate of Occupancy
05/11/2020 Letter INSPECTION SUMMARY
05/11/2020 Letter INSPECTION SUMMARY
05/26/2020 Letter Field Certificate of Occupancy
05/26/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home