Permit Application Status

PRRES20191386


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20191386
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
05/30/2019
06/10/2019
08/12/2020
Locations
Contacts
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
FIVE STAR PLUMBING INC, Address:P O BOX 452, Phone:(816) 228-8821  
BSHELTON@IQHOMEBUILDERS.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/03/2019 06/05/2019
Steve Conrick
As-graded plot plan
Corrective Action Required
06/03/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *As graded plot plan
Residential Plan Review Approved 06/03/2019 05/30/2019
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,151.74 $1,151.74 Paid 06/10/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/10/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/10/2019
8331507-Sewer Connection Fee $570.00 $570.00 Paid 06/10/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 06/10/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 06/10/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/14/2019 (11:30) 6/14/2019 06/14/2019
Erosion Control Inspection Residential Failed 06/14/2019
Miscellaneous Correction
Corrective Action Required
06/14/2019
Need to establish erosion control before next inspection
Footing Inspection - Residential Failed 6/18/2019 (11:30) 6/18/2019 06/18/2019
Misc
Corrective Action Required
06/18/2019
Failed- No address. =-no erosion control. --filled in drainage swale at the rear with dig out . --no plans on site, AB showed up before i left. --missing grade beam footing at front of stairs in basement.
Footing Inspection - Residential Passed 6/19/2019 (10:00) 6/19/2019 06/19/2019
Misc
Resolved
06/19/2019
Failed- No address. =-no erosion control. --filled in drainage swale at the rear with dig out . --no plans on site, AB showed up before i left. --missing grade beam footing at front of stairs in basement.
Underslab Plumbing Inspection - Residential Passed 7/10/2019 7/10/2019 07/10/2019
Sewer Service Inspection - R Passed 7/17/2019 7/17/2019 07/17/2019
Water Service Inspection - R Passed 7/18/2019 (11:00) 7/18/2019 07/18/2019
Piers/Caissons Inspection - Residential Passed 9/3/2019 09/03/2019
Electrical Service Inspection Passed 9/27/2019 9/27/2019 09/27/2019
Gas Service Inspection - Residential Passed 09/27/2019
Gas Piping Inspection - Residential Passed 09/27/2019
All Rough Inspection - Residential Failed 9/27/2019 9/27/2019 09/27/2019
Misc
Corrective Action Required
09/27/2019
-fix erosion control around the lot -Protect electrical in west corner of garage and middle column in garage -add stud to NE kitchen wall for siding seam -secure gas line for fireplace -protect 3” piping and waterline at top and bottom plate, NW wall in living room. And strap top and bottom plate -missing joists hangers on SW side of garage -no plans on site
Erosion Control Inspection Residential Failed 10/1/2019 10/01/2019
Miscellaneous Correction
Corrective Action Required
06/14/2019
Need to repair and maintain erosion control before next inspection
All Rough Inspection - Residential Passed 10/1/2019 10/1/2019 10/01/2019
Misc
Resolved
10/01/2019
-fix erosion control around the lot -Protect electrical in west corner of garage and middle column in garage -add stud to NE kitchen wall for siding seam -secure gas line for fireplace -protect 3” piping and waterline at top and bottom plate, NW wall in living room. And strap top and bottom plate -missing joists hangers on SW side of garage -no plans on site
Driveway Inspection Partial 11/15/2019 11/15/2019 11/18/2019
Misc
Corrective Action Required
11/18/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate. The drive approach is formed over 36’ ft and needs to be corrected to be less than 36’ ft.
Driveway Inspection Passed 11/25/2019 12/09/2019
Misc
Corrective Action Required
11/18/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate. The drive approach is formed over 36’ ft and needs to be corrected to be less than 36’ ft.
Sidewalk Inspection Partial 12/23/2019 12/23/2019 12/23/2019
Misc
Informational
12/23/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 12/30/2019 01/02/2020
Misc
Informational
12/23/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 3/19/2020 3/19/2020 03/19/2020
Misc
Corrective Action Required
03/18/2020
--NOTE; As-Graded Plot plan required.
Misc
Corrective Action Required
03/19/2020
- provide as graded plot plan - provide final grade, sod, splash blocks < Permit pulled after April 1 2019 shall meet code requirements ( NEC 2017) - AFCI required per NEC 210.12 - Tamper- resistant receptacles per 406.12 - dish washer & laundry outlets GFCI protection per 210.8 (A) & (D) - for all future construction, 20 amp garage circuit and outlets shall be required per NEC 210.11(C) (4) & 210.52 (G) (1) - provide 3 GFCI receptacles in garage - provide GFCI protection dishwasher & washing machine - provide lock out at service panel for range hood & microwave - GFCI basement under stairs not working - provide hose bib and anti siphon device at main shutoff - seal top of meter can A/C disconnect
Erosion Control Inspection Residential Failed 3/19/2020 03/19/2020
Miscellaneous Correction
Corrective Action Required
10/01/2019
Need to repair and maintain erosion control before next inspection
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/19/2020
MAINTAIN EROSION CONTROL
Occupancy Inspection - Codes Residential Failed 3/24/2020 3/24/2020 03/24/2020
Misc
Resolved
03/25/2020
--NOTE; As-Graded Plot plan required.
Misc
Corrective Action Required
03/19/2020
- provide final grade, sod, splash blocks
Occupancy Inspection - Codes Residential Temporary C of O 3/24/2020 03/24/2020
Misc
Corrective Action Required
03/19/2020
--NOTE; As-Graded Plot plan required.
Misc
Corrective Action Required
03/19/2020
- provide as graded plot plan - provide final grade, sod, splash blocks < Permit pulled after April 1 2019 shall meet code requirements ( NEC 2017) - AFCI required per NEC 210.12 - Tamper- resistant receptacles per 406.12 - dish washer & laundry outlets GFCI protection per 210.8 (A) & (D) - for all future construction, 20 amp garage circuit and outlets shall be required per NEC 210.11(C) (4) & 210.52 (G) (1) - provide 3 GFCI receptacles in garage - provide GFCI protection dishwasher & washing machine - provide lock out at service panel for range hood & microwave - GFCI basement under stairs not working - provide hose bib and anti siphon device at main shutoff - seal top of meter can A/C disconnect
Plot Plan Inspection Passed 3/25/2020 03/25/2020
Occupancy Inspection - Codes Residential Full C of O 8/12/2020 08/12/2020
Misc
Resolved
08/12/2020
--NOTE; As-Graded Plot plan required.
Misc
Resolved
08/12/2020
- provide as graded plot plan - provide final grade, sod, splash blocks
Documents & Images
Date Uploaded File Type Document Name
06/03/2019 Letter Codes Residential Plan Review
06/10/2019 Receipt Receipt for transaction: 2019-003433
06/10/2019 Letter Codes Building Permit
06/12/2019 Plot Plan DOC061219-06122019083052
06/14/2019 Letter INSPECTION SUMMARY
06/14/2019 Letter INSPECTION SUMMARY
06/14/2019 Letter INSPECTION SUMMARY
06/18/2019 Letter INSPECTION SUMMARY
06/19/2019 Letter INSPECTION SUMMARY
07/10/2019 Letter INSPECTION SUMMARY
07/17/2019 Letter INSPECTION SUMMARY
07/18/2019 Letter INSPECTION SUMMARY
09/03/2019 Letter INSPECTION SUMMARY
09/27/2019 Letter INSPECTION SUMMARY
09/27/2019 Letter INSPECTION SUMMARY
09/27/2019 Letter INSPECTION SUMMARY
09/27/2019 Letter INSPECTION SUMMARY
10/01/2019 Letter INSPECTION SUMMARY
10/01/2019 Letter INSPECTION SUMMARY
11/18/2019 Letter INSPECTION SUMMARY
12/09/2019 Letter INSPECTION SUMMARY
12/09/2019 Letter INSPECTION SUMMARY
12/23/2019 Letter INSPECTION SUMMARY
01/02/2020 Letter INSPECTION SUMMARY
01/02/2020 Letter INSPECTION SUMMARY
03/19/2020 Letter INSPECTION SUMMARY
03/19/2020 Letter INSPECTION SUMMARY
03/24/2020 Letter INSPECTION SUMMARY
03/24/2020 Plot Plan LOT 676 ASBUILT
03/24/2020 Letter Codes Temporary Certificate of Occupancy
03/25/2020 Letter INSPECTION SUMMARY
08/12/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home