Permit Application Status

PRRES20191206


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20191206
Building Permit - Residential
Certificate of Occupancy
KEVIN HIGDON CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK
05/09/2019
05/16/2019
08/11/2022
Locations
Contacts
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
KEVIN@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/13/2019 05/14/2019
Steve Conrick
As-graded plot plan
Corrective Action Required
05/14/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *Add note in a bubble, "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING."
Residential Plan Review Approved 05/13/2019 05/10/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $980.48 $980.48 Paid Not payable online 05/16/2019
8331507-Sewer Connection Fee $390.00 $390.00 Paid Not payable online 05/16/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid Not payable online 05/16/2019
8350015-Water Meter Fee $408.37 $408.37 Paid Not payable online 05/16/2019
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid Not payable online 05/16/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid Not payable online 05/16/2019
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid Not payable online 05/16/2019
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/08/2022
Outstanding Fees Amount Paid Owing Date Paid
9110078-Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/29/2019 (4:30) 5/29/2019 at 3:30 PM 05/29/2019
Sewer Service Inspection - R Failed 6/12/2019 6/12/2019 06/12/2019
Misc
Corrective Action Required
06/12/2019
No address posted No erosion control
Sewer Service Inspection - R Passed 6/14/2019 06/14/2019
Misc
Resolved
06/14/2019
No address posted No erosion control
Underslab Plumbing Inspection - Residential Passed 6/14/2019 6/14/2019 at 12:15 PM 06/14/2019
Water Service Inspection - R Passed 6/17/2019 6/17/2019 06/17/2019
Piers/Caissons Inspection - Residential Passed 7/11/2019 (9:00) 7/11/2019 at 9:26 AM 07/11/2019
Gas Piping Inspection - Residential Passed 8/28/2019 8/28/2019 08/28/2019
All Rough Inspection - Residential Failed 9/11/2019 9/11/2019 09/11/2019
Miscellaneous Correction
Corrective Action Required
09/11/2019
** Plans were not on site **
Electrical Service Inspection Passed 9/11/2019 9/11/2019 09/11/2019
Gas Service Inspection - Residential Passed 9/11/2019 9/11/2019 09/11/2019
All Rough Inspection - Residential Failed 9/17/2019 09/17/2019
Miscellaneous Correction
Resolved
09/17/2019
** Plans were not on site **
Miscellaneous Correction
Corrective Action Required
09/17/2019
** Beam in kitchen does not have a column under it. ** Rafters gap from hip-ridge beam over kitchen. ** Basement lag bolts need to be tightened. ** Missing smoke detector in bedroom 4.
All Rough Inspection - Residential Passed 9/23/2019 9/23/2019 09/23/2019
Miscellaneous Correction
Resolved
09/23/2019
** Beam in kitchen does not have a column under it. ** Rafters gap from hip-ridge beam over kitchen. ** Basement lag bolts need to be tightened. ** Missing smoke detector in bedroom 4.
Driveway Inspection Partial 10/14/2019 (A.M.) 10/14/2019 10/14/2019
Misc
Informational
10/14/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 10/14/2019 10/18/2019 10/23/2019
Driveway Inspection Passed 10/21/2019 10/23/2019
Misc
Informational
10/14/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 2/13/2020 2/13/2020 02/13/2020
Misc
Corrective Action Required
02/13/2020
- Interconnection required for all smoke/co detectors - Handrails required for garage stairs - Permit pulled after April 1st 2019 shall meet (NEC 2017) requirements for GFCI protection for washing machine outlet and dishwasher outlet - AFCI protection required for all outlets in kitchen, family rooms, dining rooms, living rooms, bedrooms, recreation rooms, closets, hallways, laundry areas. - Basement window well egress ladder required - Electrical outlet by front entry exterior not working or no current where GFCI test could be conducted - Terminate outlet at exterior, back of house by walkout, exposed wiring - Seal around all exterior light fixtures - Single doors to garage to be self closing - Door required to garage from front entry, currently framed as a cased opening - Re-inspection is required when model home office is converted back to a garage before CO
Investigation Inspection Complete 10/13/2020 10/14/2020
Misc
Informational
10/13/2020
Water Dept. says that the manhole on this property has been buried . I am going out today to check on it. Please do not give final occupancy until this is resolved.
Misc
Informational
10/14/2020
This one if fine. No manhole issues.
Plot Plan Inspection Passed 8/9/2022 08/09/2022
Occupancy Inspection - Codes Residential Failed 8/10/2022 8/10/2022 08/10/2022
Misc
Corrective Action Required
08/09/2022
-GRASPABLE HANDRAIL GARAGE STAIRS PER CODE IRC R311.7.8.5 -COMPLETE DECK STAIRS, GUARDRAIL, AND HANDRAIL
Occupancy Inspection - Codes Residential Ready for Temp CO 08/10/2022
Misc
Corrective Action Required
02/13/2020
-COMPLETE DECK STAIRS, GUARDRAIL, AND HANDRAIL
Occupancy Inspection - Codes Residential Full C of O 08/11/2022
Misc
Resolved
08/11/2022
Documents & Images
Date Uploaded File Type Document Name
05/14/2019 Letter Codes Residential Plan Review
05/16/2019 Receipt Receipt for transaction: 2019-002364
05/16/2019 Letter Codes Building Permit
05/17/2019 Plot Plan DOC051719-05172019090818
05/29/2019 Letter INSPECTION SUMMARY
06/12/2019 Letter INSPECTION SUMMARY
06/14/2019 Letter INSPECTION SUMMARY
06/14/2019 Letter INSPECTION SUMMARY
06/17/2019 Letter INSPECTION SUMMARY
06/17/2019 Letter INSPECTION SUMMARY
07/11/2019 Letter INSPECTION SUMMARY
08/28/2019 Letter INSPECTION SUMMARY
09/11/2019 Letter INSPECTION SUMMARY
09/11/2019 Letter INSPECTION SUMMARY
09/11/2019 Letter INSPECTION SUMMARY
09/23/2019 Letter INSPECTION SUMMARY
10/14/2019 Letter INSPECTION SUMMARY
10/23/2019 Letter INSPECTION SUMMARY
10/23/2019 Letter INSPECTION SUMMARY
02/13/2020 Letter INSPECTION SUMMARY
10/13/2020 Letter DE-Daily Inspection Summary
10/14/2020 Letter DE-Daily Inspection Summary
03/03/2021 Letter Codes 180 Day Letter
07/25/2022 Final_2022_07_21_DPiers_LSMO_FECO
08/08/2022 Plot Plan Approved As Graded Plot Plan
08/08/2022 Email 1717 Sw blackstone
08/08/2022 Receipt Receipt for transaction:2022-006496
08/09/2022 Letter INSPECTION SUMMARY
08/09/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter Codes Final Certificate of Occupancy
08/11/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home