Summary
PRRES20190895
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
04/11/2019
05/02/2019
09/22/2021
Locations
Contacts
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
JIM@SABHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 04/15/2019 04/30/2019
Kim Brennan
Misc
Corrective Action Required
04/11/2019

Address on the plans are incorrect.
Miscellaneous Correction
Corrective Action Required
04/11/2019

The plans reference the 2012 IRC and needs to reference the 2018 IRC
Plot Plan Review Approved 04/15/2019 04/15/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $956.28 $956.28 Paid 05/02/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/02/2019
8331507-Sewer Connection Fee $390.00 $390.00 Paid 05/02/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 05/02/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 05/02/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 05/02/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/22/2019 (4:00) 5/22/2019 05/22/2019
Sewer Service Inspection - R Passed 6/4/2019 (11:30) 6/4/2019 06/04/2019
Water Service Inspection - R Partial 06/04/2019
Water Service Inspection - R Passed 6/5/2019 (9:30) 6/5/2019 06/05/2019
Underslab Plumbing Inspection - Residential Failed 6/18/2019 06/18/2019
Misc
Corrective Action Required
06/18/2019
no erosion control no inspection
Underslab Plumbing Inspection - Residential Passed 6/21/2019 6/21/2019 06/21/2019
Misc
Resolved
06/21/2019
no erosion control no inspection
Electrical Service Inspection Passed 8/28/2019 8/28/2019 08/28/2019
Gas Service Inspection - Residential Passed 8/28/2019 8/28/2019 08/28/2019
All Rough Inspection - Residential Failed 8/28/2019 8/28/2019 08/28/2019
Misc
Corrective Action Required
08/28/2019
** Bedroom two is missing its rafter ties along the bottom 1/3 of the rafters ** ** Two 2X6 rafters have a 1/2” gap from the ridge board above bedroom 2 ** ** Need stud shoe in master bedroom closet on outside wall ** ** Too many wires in utility room switch. 22 cu. in. of wire in a 20.5 cu.in. Box** ** Wall outlets in basement room are 13’ apart. Max spacing is 12’ ** ** Wall outlets in living room are 13’ apart. Max spacing is 12’ ** ** Missing collar ties at ridge (through out ) ** **Missing braced wall straps at header of garage doors **
All Rough Inspection - Residential Passed 9/4/2019 9/4/2019 09/04/2019
Misc
Resolved
09/04/2019
Ok to insulate
Electrical Service Inspection Passed 9/4/2019 09/04/2019
Driveway Inspection Partial 9/26/2019 09/26/2019
Misc
Informational
09/26/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 10/3/2019 10/03/2019
Misc
Informational
09/26/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 12/11/2019 12/11/2019 at 2:10 PM 12/11/2019
Misc
Corrective Action Required
12/11/2019
**PERMIT PULLED AFTER APRIL-1 OF 2019 SHALL MEET CODE (NEC 2017) REQUIREMENTS: -AFCI REQUIRED PER NEC 210.12 -TAMPER-RESISTANT RECEPTACLES PER 406.12 -DISH WASHER&LAUNDRY OUTLETS GFCI PROTECTION PER 210.8(A) AND (D). -FOR ALL FUTURE CONSTRUCTIONS, 20 AMP GARAGE CIRCUIT AND OUTLETS SHALL BE REQUIRED PER NEC 210.11(C)(4) AND 210.52(G)(1) -Provide erosion control along street until sodding -Locate the sewer tracer wire and install box -Lawn irrigation permit -Final grade, sod, 3ft downspout extensions, sump pump discharge min 3 ft from house -Install guardrail at open side of stoop floor more than 30” from grade -Garage attic access panel missing -Install breaker lock for kitchen hood -Cooler receptacle within six ft of the wet bar sink shall be gfci-protected -Install joist hangers above water heater -Install double wall interconnecting fitting at common vent connection
Occupancy Inspection - Codes Residential Temporary C of O 12/23/2019 12/23/2019 12/23/2019
Misc
Corrective Action Required
12/11/2019
**PERMIT PULLED AFTER APRIL-1 OF 2019 SHALL MEET CODE (NEC 2017) REQUIREMENTS -FOR ALL FUTURE CONSTRUCTIONS, 20 AMP GARAGE CIRCUIT AND OUTLETS SHALL BE REQUIRED PER NEC 210.11(C)(4) AND 210.52(G)(1) -Locate the sewer tracer wire and install box -Lawn irrigation permit -Final grade, sod, 3ft downspout extensions, sump pump discharge min 3 ft from house
Occupancy Inspection - Codes Residential Full C of O 09/22/2021
Misc
Resolved
09/22/2021
(1) -Locate the sewer tracer wire and install box -Lawn irrigation permit -Final grade, sod, 3ft downspout extensions, sump pump discharge min 3 ft from house
Documents & Images
Date Uploaded File Type Document Name
04/11/2019 Letter Codes Residential Plan Review
05/02/2019 Receipt Receipt for transaction: 2019-001711
05/02/2019 Letter Codes Building Permit
05/02/2019 Plot Plan DOC050219-05022019110803
05/22/2019 Letter INSPECTION SUMMARY
06/04/2019 Letter INSPECTION SUMMARY
06/04/2019 Letter INSPECTION SUMMARY
06/05/2019 Letter INSPECTION SUMMARY
06/18/2019 Letter INSPECTION SUMMARY
06/21/2019 Letter INSPECTION SUMMARY
08/28/2019 Letter INSPECTION SUMMARY
08/28/2019 Letter INSPECTION SUMMARY
08/28/2019 Letter INSPECTION SUMMARY
09/04/2019 Letter INSPECTION SUMMARY
09/04/2019 Letter INSPECTION SUMMARY
09/26/2019 Letter INSPECTION SUMMARY
10/03/2019 Letter INSPECTION SUMMARY
12/11/2019 Letter INSPECTION SUMMARY
12/23/2019 Letter Codes Temporary Certificate of Occupancy
09/22/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home