Permit Application Status

PRRES20190414


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20190414
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT COVERED DECK
02/25/2019
03/12/2019
04/24/2020
Locations
Contacts
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
JIM@SABHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/27/2019 02/27/2019
Steve Conrick
Residential Plan Review Approved 02/27/2019 02/25/2019
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,048.55 $1,048.55 Paid 03/12/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/12/2019
8331507-Sewer Connection Fee $480.00 $480.00 Paid 03/12/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 03/12/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 03/12/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/22/2019 4/9/2019 04/09/2019
Sewer Service Inspection - R Passed 4/22/2019 4/22/2019 at 10:10 AM 04/22/2019
Water Service Inspection - R Passed 4/23/2019 4/23/2019 04/23/2019
Gas Service Inspection - Residential Passed 7/15/2019 7/15/2019 07/15/2019
Electrical Service Inspection Failed 7/15/2019 7/15/2019 07/15/2019
Misc
Corrective Action Required
07/15/2019
locate ufer ground
All Rough Inspection - Residential Failed 7/15/2019 7/15/2019 07/15/2019
Misc
Corrective Action Required
07/15/2019
- fire stop throughout. - fire stop box in 2nd bedroom. - firestop basement walls, fur downs, drop ceiling, where i beams meet fur downs, dead space angle wall in bsmt. - flue clearance at 1st floor. - secure gas line at fire place. -plans show 2x6 rear basment exterior wall revise plans or provide engineer report.
All Rough Inspection - Residential Failed 7/18/2019 7/18/2019 07/18/2019
Misc
Corrective Action Required
07/15/2019
-plans show 2x6 rear basment exterior wall revise plans or provide engineer report. Locate Ufer ground - attempt to locate location , contact Foundation contractor and or use window cut out for steel
Electrical Service Inspection Failed 7/18/2019 7/18/2019 07/18/2019
Misc
Corrective Action Required
07/15/2019
locate ufer ground\\\ Locate Ufer ground - attempt to locate location , contact Foundation contractor and or use window cut out for steel
Electrical Service Inspection Passed 7/26/2019 7/26/2019 07/26/2019
Misc
Resolved
07/26/2019
locate ufer ground\\\ Locate Ufer ground - attempt to locate location , contact Foundation contractor and or use window cut out for steel
All Rough Inspection - Residential Failed 7/26/2019 7/26/2019 07/26/2019
Misc
Corrective Action Required
07/18/2019
-plans show 2x6 rear basment exterior wall revise plans or provide engineer report.
All Rough Inspection - Residential Passed 7/31/2019 7/31/2019 07/31/2019
Misc
Resolved
07/31/2019
-plans show 2x6 rear basment exterior wall revise plans or provide engineer report.
Driveway Inspection Partial 9/25/2019 9/25/2019 09/25/2019
Misc
Informational
09/25/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 10/2/2019 10/03/2019
Misc
Informational
09/25/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Plot Plan Inspection Passed 4/24/2020 03/26/2020
Occupancy Inspection - Codes Residential Failed 3/26/2020 3/26/2020 03/26/2020
Misc
Resolved
04/24/2020
Piers/Caissons Inspection - Residential Passed 4/24/2020 04/24/2020
Misc
Corrective Action Required
04/24/2020
- pouring footing inlo deck pier -
Underslab Plumbing Inspection - Residential Passed 4/24/2020 04/24/2020
Occupancy Inspection - Codes Residential Full C of O 4/24/2020 4/24/2020 04/24/2020
Documents & Images
Date Uploaded File Type Document Name
03/12/2019 Receipt Receipt for transaction: 2019-000799
03/12/2019 Letter Codes Building Permit
03/14/2019 Plot Plan DOC031419-03142019080041
04/09/2019 Letter INSPECTION SUMMARY
04/22/2019 Letter INSPECTION SUMMARY
04/23/2019 Letter INSPECTION SUMMARY
07/15/2019 Letter INSPECTION SUMMARY
07/15/2019 Letter INSPECTION SUMMARY
07/15/2019 Letter INSPECTION SUMMARY
07/18/2019 Letter INSPECTION SUMMARY
07/26/2019 Letter INSPECTION SUMMARY
07/26/2019 Letter INSPECTION SUMMARY
07/31/2019 Letter INSPECTION SUMMARY
09/25/2019 Letter INSPECTION SUMMARY
10/03/2019 Letter INSPECTION SUMMARY
03/26/2020 Letter INSPECTION SUMMARY
04/24/2020 Letter Codes Final Certificate of Occupancy
04/24/2020 Letter Codes Final Certificate of Occupancy
04/24/2020 Letter Field Certificate of Occupancy
04/24/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home