Permit Application Status

PRRES20184098


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20184098
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT COVERED DECK
12/12/2018
12/27/2018
11/13/2019
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
KC CUSTOM HOMES, Address:406 NW DONOVAN RD, Phone:(816) 564-5149  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ADVANCED ELECTRICAL LLC, Address:PO BOX 1573, Phone:(816) 347-8187  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
steve@kc-customhomes.com  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 12/14/2018 12/20/2018
Brandon Kalwei
Plot Plan Review Approved 12/14/2018 12/20/2018
Steve Conrick
Misc
Corrective Action Required
12/13/2018

***Show floodzone***
Basement opening elevations
Corrective Action Required
12/13/2018

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. ***The MDP gives an MBOE for this lot of 983.2***
As-graded plot plan
Corrective Action Required
12/13/2018

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. ***Please add "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING" in a bubble***
Spot elevations
Corrective Action Required
12/13/2018

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. ***The front of the lot is very flat and does not meet the 2% requirement.***
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,518.04 $1,518.04 Paid 12/27/2018
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/27/2018
8331504-EFHB Middle Big Creek, Full $703.08 $703.08 Paid 12/27/2018
8331507-Sewer Connection Fee $630.00 $630.00 Paid 12/27/2018
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 12/27/2018
8350015-Water Meter Fee $408.37 $408.37 Paid 12/27/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/4/2019 (1:00) 2/4/2019 at 2:00 PM 02/04/2019
Sewer Service Inspection - R Passed 2/28/2019 2/28/2019 at 2:30 PM 02/28/2019
Water Service Inspection - R Partial 2/28/2019 at 2:50 PM 02/28/2019
Piers/Caissons Inspection - Residential Passed 2/28/2019 at 3:01 PM 02/28/2019
Misc
Resolved
02/28/2019
Water Service Inspection - R Passed 3/1/2019 (10:15) 3/1/2019 at 10:00 AM 03/01/2019
Underslab Plumbing Inspection - Residential Passed 3/18/2019 3/18/2019 at 9:45 AM 03/18/2019
Misc
Corrective Action Required
03/18/2019
POST ADDRESS
Piers/Caissons Inspection - Residential Passed 6/4/2019 6/4/2019 at 1:30 PM 06/04/2019
Misc
Informational
06/04/2019
5 piers for 2 covered decks OK TO POUR
All Rough Inspection - Residential Failed 7/23/2019 7/23/2019 07/23/2019
Misc
Corrective Action Required
07/23/2019
-Cut floor joist at HVAC flue, main floor near garage door entrance. Need engineer ok -Need to fire block at top plate at HVAC heat chase and flue -fire block every 10’ at double walls in basement -fire block dead space at top plate, behind basement shower NW side -cannot locate ufer grounding -security blocking at rear garage door
Electrical Service Inspection Failed 7/23/2019 7/23/2019 07/23/2019
Misc
Corrective Action Required
07/23/2019
Green bonding screw not set in box Could not locate ufer grounding
Gas Service Inspection - Residential Failed 7/23/2019 7/23/2019 07/23/2019
Misc
Corrective Action Required
07/23/2019
No gas pressure
All Rough Inspection - Residential Partial 7/29/2019 7/29/2019 at 11:00 AM 07/29/2019
Misc
Resolved
07/29/2019
-Cut floor joist at HVAC flue, main floor near garage door entrance. Need engineer ok -Need to fire block at top plate at HVAC heat chase and flue -fire block every 10’ at double walls in basement -fire block dead space at top plate, behind basement shower NW side -cannot locate ufer grounding -security blocking at rear garage door
Misc
Corrective Action Required
07/29/2019
engineers report on overbored joist. OK TO INSULATE
Gas Piping Inspection - Residential Failed 7/29/2019 07/29/2019
Misc
Corrective Action Required
07/29/2019
0 PSI IN GAS LINE
Gas Service Inspection - Residential Failed 7/29/2019 7/29/2019 07/29/2019
Misc
Corrective Action Required
07/23/2019
No gas pressure
Misc
Corrective Action Required
07/29/2019
0 PSI IN GAS LINE
All Rough Inspection - Residential Passed 8/1/2019 at 11:00 AM 08/01/2019
Misc
Resolved
08/01/2019
engineers report on overbored joist. OK TO INSULATE
Gas Piping Inspection - Residential Passed 8/1/2019 08/01/2019
Misc
Corrective Action Required
07/29/2019
0 PSI IN GAS LINE
Gas Service Inspection - Residential Passed 8/1/2019 at 11:11 AM 08/01/2019
Misc
Resolved
08/01/2019
No gas pressure
Misc
Resolved
08/01/2019
0 PSI IN GAS LINE
Driveway Inspection Partial 8/7/2019 8/7/2019 08/08/2019
Misc
Informational
08/08/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
08/08/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Electrical Service Inspection Failed 9/20/2019 9/20/2019 09/20/2019
Misc
Resolved
07/29/2019
Green bonding screw not set in box Could not locate ufer grounding
Miscellaneous Correction
Corrective Action Required
09/20/2019
Need access to ufer ground. It has been covered by drywall
Electrical Service Inspection Passed 10/2/2019 10/2/2019 10/02/2019
Miscellaneous Correction
Resolved
10/02/2019
Need access to ufer ground. It has been covered by drywall
Occupancy Inspection - Codes Residential Failed 10/23/2019 10/23/2019 10/23/2019
Misc
Corrective Action Required
10/23/2019
- Both locking devices needed for back sliding door on main and basement level - Gfci receptacle I’m back deck is not working properly - anti siphon devise needed for hose bib in basement - lockout devices needed for microwave and oven - detector for downstairs bedroom needs to be combo unit smoke and CO - security strike plate or screws needed for door leading to downstairs garage - gfci outside of lower level garage not working properly - final grade, sod, splash blocks - seal all outside electrical fixtures, ac disconnect, etc.
Occupancy Inspection - Codes Residential Full C of O 10/24/2019 10/24/2019 11/13/2019
Misc
Resolved
11/13/2019
Occupancy Inspection - Codes Residential Full C of O 11/13/2019 11/13/2019 11/13/2019
Plot Plan Inspection Passed 11/14/2019 11/13/2019
Documents & Images
Date Uploaded File Type Document Name
12/12/2018 Letter Codes Residential Plan Review
12/13/2018 Letter Codes Residential Plan Review
12/27/2018 Receipt Receipt for transaction: 2018-007714
12/27/2018 Letter Codes Building Permit
12/31/2018 Plot Plan DOC123118-006
01/10/2019 Engineer Report/Study 1518 SW Blackstone Pl_Lot 132 Napa Valley Final_2019.01.07_SiteObv PierDes_LSMO_Shaw Construction
01/29/2019 Engineer Report/Study 1518 SW Blackstone Pl_Lot 132 Napa Valley Final_2019.01.24_HPier_LSMO_Shaw Construction
02/04/2019 Letter INSPECTION SUMMARY
02/28/2019 Letter INSPECTION SUMMARY
02/28/2019 Letter INSPECTION SUMMARY
02/28/2019 Letter INSPECTION SUMMARY
03/01/2019 Letter INSPECTION SUMMARY
03/18/2019 Letter INSPECTION SUMMARY
06/04/2019 Letter INSPECTION SUMMARY
07/23/2019 Letter INSPECTION SUMMARY
07/23/2019 Letter INSPECTION SUMMARY
07/23/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
08/01/2019 Letter INSPECTION SUMMARY
08/01/2019 Letter INSPECTION SUMMARY
08/01/2019 Letter INSPECTION SUMMARY
08/08/2019 Letter INSPECTION SUMMARY
08/15/2019 Engineer Report/Study DOC081219-08122019141625
09/20/2019 Letter INSPECTION SUMMARY
10/02/2019 Letter INSPECTION SUMMARY
10/23/2019 Letter INSPECTION SUMMARY
10/24/2019 Letter Codes Temporary Certificate of Occupancy
11/13/2019 LOT 132A ASBUILT
11/13/2019 Letter Codes Final Certificate of Occupancy
11/13/2019 Letter Field Certificate of Occupancy
11/13/2019 Letter Codes Final Certificate of Occupancy
11/13/2019 Letter Field Certificate of Occupancy
11/13/2019 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home