Permit Application Status

PRRES20183796


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20183796
Building Permit - Residential
Certificate of Occupancy
ACH DEVELOPMENT II LLC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK
11/05/2018
11/16/2018
08/14/2019
Locations
Contacts
ACH DEVELOPMENT II LLC, Address:3170 NE CARNEGIE DR STE 400  
GARY KRUEGER HOMES, Address:309 SE WESTMINISTER RD, Phone:(816) 228-1426  
FOXWOOD SERVICES LLC, Address:2035 TELEVISION PL, Phone:(816) 252-1800  
ADVANCED ELECTRICAL LLC, Address:PO BOX 1573, Phone:(816) 347-8187  
ACCU-PLUMBING INC, Address:PO BOX 683, Phone:(816) 229-4776  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 11/07/2018 11/07/2018
Kim Brennan
10 Combustion air
Corrective Action Required
11/05/2018

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
11/05/2018

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) does not specify uninterrupted height
Miscellaneous Correction
Corrective Action Required
11/05/2018

Please provide the address to the property on all pages of the drawings
Miscellaneous Correction
Corrective Action Required
11/05/2018

Application does not specify covered deck but a covered deck is shown on the plans. Please advise
Miscellaneous Correction
Corrective Action Required
11/05/2018

Application was not filled out entirely. The box as to whether there is a drainage swale required was not filled in. Please advise
Plot Plan Review Approved 11/07/2018 11/07/2018
Steve Conrick
As-graded plot plan
Corrective Action Required
11/06/2018

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. ***Please add a bubble that says "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING"***
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,059.97 $1,059.97 Paid 11/16/2018
Right of Way Permit Fee $80.00 $80.00 Paid 11/16/2018
8331507-Sewer Connection Fee $420.00 $420.00 Paid 11/16/2018
Water Tap Fee $3,409.00 $3,409.00 Paid 11/16/2018
Water Meter Fee $408.37 $408.37 Paid 11/16/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 11/21/2018 (1:00) 11/21/2018 at 1:15 PM 11/21/2018
Misc
Corrective Action Required
11/21/2018
-HAVE ENGINEER OK THE GARAGE FOOTING WITHOUT DEADMAN LOCATED IN LINE WITH THE 4 36" PADS
Underslab Plumbing Inspection - Residential Passed 12/20/2018 12/20/2018 at 9:05 AM 12/20/2018
Piers/Caissons Inspection - Residential Passed 1/4/2019 1/4/2019 at 8:45 AM 01/04/2019
Rough Framing Inspection - Residential Passed 2/22/2019 2/22/2019 at 11:05 AM 02/22/2019
Erosion Control Inspection Residential Failed 3/8/2019 03/08/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/08/2019
DEFICIENT EROSION CONTROL INSTALLATION. EROSION CONTROL MUST BE RE-ESTABLISHED. STREET SHALL BE KEPT CLEAN NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Gas Service Inspection - Residential Passed 3/8/2019 3/8/2019 at 8:35 AM 03/08/2019
Misc
Informational
03/08/2019
*SEE EROSION CONTROL*
All Rough Inspection - Residential Failed 3/25/2019 3/25/2019 at 9:35 AM 03/25/2019
Misc
Corrective Action Required
03/25/2019
FRAMING: -Complete garage portal wall. Install blocking at seams and nail sheathing -Nail CFPF wall siding per plan -Nail corner studs per code -Nail ceiling beam hanger above master bedroom -Install ceiling joist hanger above rear dining -Nail in hanger above front bedroom; support hips at A frame -Solidblock cantilevered joists in basement MECHANICAL: -Install b vent shield in attic -Provide proper clearance around fireplace flue -Unblock return air above wet bar PLUMBING: -Protect 3” waste stack at rear basement bedroom ELECTRICAL: -Flood light at rear -Secure and support all wiring per code in basement. Cannot just rest wiring on framing **OK TO INSULATE
Electrical Service Inspection Failed 3/25/2019 3/25/2019 03/25/2019
Misc
Corrective Action Required
03/25/2019
-Bond service panel enclosure -Only same size EGC in each lug -Tighten SE connector fitting
All Rough Inspection - Residential Passed 3/28/2019 3/28/2019 at 9:15 AM 03/28/2019
Misc
Resolved
03/28/2019
FRAMING: -Complete garage portal wall. Install blocking at seams and nail sheathing -Nail CFPF wall siding per plan -Nail corner studs per code -Nail ceiling beam hanger above master bedroom -Install ceiling joist hanger above rear dining -Nail in hanger above front bedroom; support hips at A frame -Solidblock cantilevered joists in basement MECHANICAL: -Install b vent shield in attic -Provide proper clearance around fireplace flue -Unblock return air above wet bar PLUMBING: -Protect 3” waste stack at rear basement bedroom ELECTRICAL: -Flood light at rear -Secure and support all wiring per code in basement. Cannot just rest wiring on framing **OK TO INSULATE
Electrical Service Inspection Passed 3/28/2019 3/28/2019 03/28/2019
Misc
Resolved
03/28/2019
-Bond service panel enclosure -Only same size EGC in each lug -Tighten SE connector fitting
Water Service Inspection - R Partial 4/9/2019 04/09/2019
Sewer Service Inspection - R Passed 4/9/2019 4/9/2019 at 2:50 PM 04/09/2019
Water Service Inspection - R Passed 4/10/2019 (8:45) 4/10/2019 at 9:25 AM 04/10/2019
Driveway Inspection Partial 5/15/2019 5/15/2019 05/20/2019
Misc
Informational
05/20/2019
The driveway was formed, rock was installed and compacted.
Driveway Inspection Passed 5/21/2019 05/21/2019
Misc
Informational
05/20/2019
The driveway was formed, rock was installed and compacted.
Misc
Informational
05/21/2019
The driveway has been poured and appears to meet all city standards.
Sidewalk Inspection Passed 7/8/2019 7/8/2019 07/11/2019
Misc
Informational
07/08/2019
Sidewalk - forms and materials passed pre-inspection .
Misc
Informational
07/11/2019
Sidewalk - passed final inspection .
Footing Inspection - Residential Passed 07/16/2019
Misc
Resolved
07/16/2019
-HAVE ENGINEER OK THE GARAGE FOOTING WITHOUT DEADMAN LOCATED IN LINE WITH THE 4 36" PADS
Occupancy Inspection - Codes Residential Failed 7/16/2019 7/16/2019 at 10:10 AM 07/16/2019
Misc
Corrective Action Required
07/16/2019
-Sidewalk not approved in record -Final grade, sod, splashblocks. As-graded plot plan is required prior to grading -Roof drainage -Secure NM cable within 12” of panel -Provide min 1” clearance to water heater b-vent -Screw the rear door brace to studs -Install box extensions for floor receptacles
Occupancy Inspection - Codes Residential Temporary C of O 7/18/2019 at 9:15 AM 07/18/2019
Misc
Corrective Action Required
07/16/2019
-Final grade, sod, splashblocks. As-graded plot plan is required prior to grading
Plot Plan Inspection Passed 7/19/2019 07/22/2019
Erosion Control Inspection Residential Passed 08/14/2019
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/16/2019
DEFICIENT EROSION CONTROL INSTALLATION. EROSION CONTROL MUST BE RE-ESTABLISHED. STREET SHALL BE KEPT CLEAN NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Full C of O 8/14/2019 at 11:25 AM 08/14/2019
Misc
Resolved
08/14/2019
-Final grade, sod, splashblocks. As-graded plot plan is required prior to grading -Verify meter well is cleaned and not full of mud
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit