Summary
PRRES20183171
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
09/19/2018
10/04/2018
01/16/2020
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
steve@kc-customhomes.com  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 09/21/2018 10/04/2018
Kim Brennan
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
09/19/2018

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Plot Plan Review Approved 09/21/2018 10/04/2018
Steve Conrick
Lot elevations
Corrective Action Required
09/24/2018

Existing and finish elevations at all property corners must be provided on the plot plan. ***The elevations at the NW and SE property corners are over 1.0 ft higher than what is shown on the MDP. Please verify that your shots are what is existing and that waster is still flowing how it was designed on the the MDP***
Basement elevation
Corrective Action Required
09/24/2018

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) ***The MDP calls for a Standard basement. Please get approval from the design engineer of Napa Valley 3rd Plat to move forward with the Daylight Basement.***
As-graded plot plan
Corrective Action Required
09/24/2018

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. ***Please add "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING" in a bubble.***
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $799.57 $799.57 Paid 10/04/2018
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/04/2018
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 10/04/2018
8331507-Sewer Connection Fee $390.00 $390.00 Paid 10/04/2018
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 10/04/2018
8350015-Water Meter Fee $408.37 $408.37 Paid 10/04/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/5/2018 at 1:30 PM 10/04/2018
Sewer Service Inspection - R Passed 10/17/2018 10/17/2018 at 1:35 PM 10/17/2018
Water Service Inspection - R Partial 10/18/2018 10/18/2018 10/17/2018
Water Service Inspection - R Passed 10/18/2018 at 9:15 AM 10/18/2018
Underslab Plumbing Inspection - Residential Passed 10/24/2018 10/24/2018 at 8:01 AM 10/24/2018
Gas Piping Inspection - Residential Failed 1/3/2019 1/3/2019 at 9:20 AM 01/03/2019
Misc
Corrective Action Required
01/03/2019
* FIRE PLACE IS NOT INSTALLED * GAS LINE IS NOT BONDED
All Rough Inspection - Residential Not Ready 1/28/2019 1/28/2019 01/28/2019
Misc
Corrective Action Required
01/28/2019
- no plans - no erosion control.
Gas Piping Inspection - Residential Passed 2/12/2019 2/12/2019 at 8:30 AM 02/12/2019
Misc
Resolved
02/12/2019
* FIRE PLACE IS NOT INSTALLED * GAS LINE IS NOT BONDED
Gas Service Inspection - Residential Passed 2/12/2019 2/12/2019 02/12/2019
All Rough Inspection - Residential Not Ready 2/12/2019 2/12/2019 at 8:45 AM 02/12/2019
Misc
Corrective Action Required
01/28/2019
- no plans
Misc
Corrective Action Required
02/12/2019
NO PLANS ON SITE
Electrical Service Inspection Passed 2/12/2019 2/12/2019 at 9:00 AM 02/12/2019
All Rough Inspection - Residential Failed 2/13/2019 2/13/2019 at 11:30 AM 02/13/2019
Misc
Resolved
02/13/2019
- no plans
Misc
Resolved
02/13/2019
NO PLANS ON SITE
Misc
Resolved
02/26/2019
Fire stop nm electrical penetration left of radon chase in garage. Fire block fireplace to attic space. Fire stop gas line penetration at fireplace. Fire block top of great room wall opposite of laundry rm. fire block top of wall from master entry hall to return air space. Fire block stairway wall from mid stairs to front door. Support hip and valley above mudroom (purlin). Install boot at plumbing vent over master bath. Add strong backs to purlins throughout.
All Rough Inspection - Residential Passed 2/26/2019 at 7:30 AM 02/26/2019
Misc
Resolved
02/26/2019
- no plans
Misc
Resolved
02/26/2019
NO PLANS ON SITE
Piers/Caissons Inspection - Residential Passed 4/19/2019 at 7:30 AM 04/19/2019
Driveway Inspection Partial 4/19/2019 4/19/2019 04/19/2019
Misc
Informational
04/19/2019
PRE POUR INSPECTION The forms are up and there appears to be a sufficient amount of compacted aggregate.
Driveway Inspection Passed 4/24/2019 04/24/2019
Misc
Informational
04/19/2019
PRE POUR INSPECTION The forms are up and there appears to be a sufficient amount of compacted aggregate.
Occupancy Inspection - Codes Residential Temporary C of O 5/29/2019 5/29/2019 at 1:00 PM 05/29/2019
Misc
Corrective Action Required
05/29/2019
1.DECK LEDGER BOARD ATTACHMENT NOT ALLOWED TO ATTACH TO CANTILEVER. DOUBLE HEADER AND DOUBLE BOTH SUPPORTING JOISTS . INSTALL JOIST HANGERS AT ALL. 2. FINAL GRADING. 3. SOD. 4. PROVIDE AS GRADED PLOT PLAN PRIOR TO SOD.
Occupancy Inspection - Codes Residential Temporary C of O 7/29/2019 at 10:31 AM 07/29/2019
Misc
Corrective Action Required
07/29/2019
1.DECK LEDGER BOARD ATTACHMENT NOT ALLOWED TO ATTACH TO CANTILEVER. DOUBLE HEADER AND DOUBLE BOTH SUPPORTING JOISTS . INSTALL JOIST HANGERS AT ALL. 2. PROVIDE AS GRADED PLOT PLAN PRIOR TO SOD.
Occupancy Inspection - Codes Residential Failed 8/29/2019 08/29/2019
Misc
Corrective Action Required
07/29/2019
1.DECK LEDGER BOARD ATTACHMENT NOT ALLOWED TO ATTACH TO CANTILEVER. DOUBLE HEADER AND DOUBLE BOTH SUPPORTING JOISTS . INSTALL JOIST HANGERS AT ALL.
Occupancy Inspection - Codes Residential Full C of O 1/16/2020 1/16/2020 01/16/2020
Misc
Resolved
01/16/2020
Documents & Images
Date Uploaded File Type Document Name
09/19/2018 Letter Codes Residential Plan Review
09/24/2018 Letter Codes Residential Plan Review
10/04/2018 Receipt Receipt for transaction: 2018-006704
10/04/2018 Letter Codes Building Permit
10/04/2018 Letter Inspection Summary
10/05/2018 Letter DOC100518-10052018084414
10/05/2018 Plot Plan DOC100518-10052018084426
10/17/2018 Letter Inspection Summary
10/18/2018 Letter Inspection Summary
10/24/2018 Letter Inspection Summary
01/03/2019 Letter INSPECTION SUMMARY
01/28/2019 Letter INSPECTION SUMMARY
02/12/2019 Letter INSPECTION SUMMARY
02/12/2019 Letter INSPECTION SUMMARY
02/12/2019 Letter INSPECTION SUMMARY
02/12/2019 Letter INSPECTION SUMMARY
02/13/2019 Letter INSPECTION SUMMARY
02/26/2019 Letter INSPECTION SUMMARY
04/19/2019 Letter INSPECTION SUMMARY
04/19/2019 Letter INSPECTION SUMMARY
04/24/2019 Letter INSPECTION SUMMARY
05/29/2019 Letter Codes Temporary Certificate of Occupancy
07/29/2019 Letter Codes Temporary Certificate of Occupancy
08/29/2019 Letter INSPECTION SUMMARY
01/16/2020 Letter Codes Final Certificate of Occupancy
01/16/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home