Permit Application Status

PRRES20182343


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20182343
Building Permit - Residential
Certificate of Occupancy
KEVIN HIGDON CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT COVERED DECK
07/24/2018
07/26/2018
11/05/2019
Locations
Contacts
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/26/2018 07/26/2018
Steve Conrick
Residential Plan Review Approved 07/26/2018 07/24/2018
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,206.85 $1,206.85 Paid 07/26/2018
Right of Way Permit Fee $80.00 $80.00 Paid 07/26/2018
8331504-EFHB Middle Big Creek, Full $569.16 $569.16 Paid 07/26/2018
8331507-Sewer Connection Fee $510.00 $510.00 Paid 07/26/2018
Water Tap Fee $3,409.00 $3,409.00 Paid 07/26/2018
Water Meter Fee $408.37 $408.37 Paid 07/26/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/8/2018 (11:30) 8/8/2018 at 11:45 AM 08/08/2018
Underslab Plumbing Inspection - Residential Passed 9/14/2018 9/14/2018 at 9:15 AM 09/14/2018
Sewer Service Inspection - R Passed 9/19/2018 (2:30) 9/19/2018 at 2:20 PM 09/19/2018
Water Service Inspection - R Passed 9/21/2018 9/21/2018 at 9:30 AM 09/21/2018
Gas Piping Inspection - Residential Passed 11/13/2018 11/13/2018 at 8:00 AM 11/13/2018
All Rough Inspection - Residential Failed 12/12/2018 12/12/2018 at 2:31 PM 12/12/2018
Misc
Corrective Action Required
12/12/2018
* NO PLANS ON SITE * NO INSPECTION PERFORMED
Electrical Service Inspection Passed 12/12/2018 12/12/2018 12/12/2018
Gas Service Inspection - Residential Passed 12/12/2018 12/12/2018 12/12/2018
All Rough Inspection - Residential Failed 12/13/2018 12/13/2018 at 3:00 PM 12/13/2018
Misc
Resolved
12/13/2018
* NO PLANS ON SITE * NO INSPECTION PERFORMED
Misc
Corrective Action Required
12/13/2018
*Nail garage portal sheathing per code 3” oc * Add anchor at east side sill plate splice in garage * Add anchor west side sill plate in garage at splice . Install all exterior doors Add anchor at west side garage sill plate at splice within 12 “. * Strap top plate at garage entry hall right side. * Fire block-basement fire place. * Solid block over beams in basement. * Add anchor southwest basement sill plate at splice *Add anchor northeast basement sill plate at splice
All Rough Inspection - Residential Passed 12/20/2018 12/20/2018 at 8:00 AM 12/20/2018
Misc
Resolved
12/20/2018
*Nail garage portal sheathing per code 3” oc * Add anchor at east side sill plate splice in garage * Add anchor west side sill plate in garage at splice . Install all exterior doors Add anchor at west side garage sill plate at splice within 12 “. * Strap top plate at garage entry hall right side. * Fire block-basement fire place. * Solid block over beams in basement. * Add anchor southwest basement sill plate at splice *Add anchor northeast basement sill plate at splice
Driveway Inspection Passed 1/9/2019 1/10/2019 at 9:35 AM 01/10/2019
Misc
Corrective Action Required
01/10/2019
Met contractor on site. The driveway and sidewalk crossing is ADA compliant and has proper aggregate and isolation joints. They are good to pour.
Investigation Inspection Complete 7/9/2019 07/09/2019
Occupancy Inspection - Codes Residential Failed 10/23/2019 10/23/2019 10/23/2019
Misc
Corrective Action Required
10/23/2019
- Secure waterline to foundation in unfurnished area if basement - must fire protect I joists in both unfinished areas of basement
Occupancy Inspection - Codes Residential Full C of O 11/5/2019 11/5/2019 11/05/2019
Misc
Resolved
11/05/2019
Documents & Images
Date Uploaded File Type Document Name
07/26/2018 Receipt Receipt for transaction: 2018-005227
07/26/2018 Letter Codes Building Permit
07/27/2018 Plot Plan DOC072718-07272018144058
08/08/2018 Letter Inspection Summary
09/14/2018 Letter Inspection Summary
09/19/2018 Letter Inspection Summary
09/21/2018 Letter Inspection Summary
11/13/2018 Letter Inspection Summary
12/12/2018 Letter INSPECTION SUMMARY
12/12/2018 Letter INSPECTION SUMMARY
12/12/2018 Letter INSPECTION SUMMARY
12/12/2018 Letter INSPECTION SUMMARY
12/13/2018 Letter INSPECTION SUMMARY
12/20/2018 Letter INSPECTION SUMMARY
01/10/2019 Letter DE-Daily Inspection Summary
01/10/2019 Letter DE-Daily Inspection Summary
05/31/2019 Letter Codes 140 Day Letter
07/09/2019 Letter Codes 180 Day Letter
10/23/2019 Letter INSPECTION SUMMARY
11/05/2019 Letter Field Certificate of Occupancy
11/05/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home