Permit Application Status

PRRES20182137


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20182137
Building Permit - Residential
Final Completion
KEVIN HIGDON CONSTRUCTION LLC
ALTERATION SINGLE FAMILY
BASEMENT FINISH
07/10/2018
07/10/2018
02/25/2020
Locations
Contacts
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
INTERSTATE ELECTRICAL CONSTRUCTION, Address:3710 ROBINSON PIKE RD, Phone:(816) 761-0200  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 07/10/2018 07/10/2018
Development Center
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Add/Alter Single Family $106.23 $106.23 Paid 07/10/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Residential Failed 1/18/2019 at 8:20 AM 01/18/2019
Misc
Corrective Action Required
01/18/2019
*PLUMBING INCOMPLETE AT BAR SINK. *FIREBLOCKING REQUIRED THROUGHOUT, AT TOP PLATE TO JOIST SPACE ON OUTSIDE WALLS, OUTSIDE WALL NEED YO BE FIRE BLOCKED VERTICALLY AT 10' INTERVAL. *BASEMENT BED NEEDS TO BE ON ARCH FAULT BREAKER
All Rough Inspection - Residential Failed 1/29/2019 1/29/2019 at 8:30 AM 01/29/2019
Misc
Partial Correction
01/29/2019
*FIREBLOCKING REQUIRED AT SOUTH WALL FIR DOWN SPACE TO STUD SPACE FROM EAST END OF FIR DOWN TO WEST END OF FIR DOWN *BASEMENT BED NEEDS TO BE ON ARCH FAULT BREAKER
All Rough Inspection - Residential Passed 1/30/2019 1/30/2019 at 8:31 AM 01/30/2019
Misc
Partial Correction
01/29/2019
*FIREBLOCKING REQUIRED AT SOUTH WALL FIR DOWN SPACE TO STUD SPACE FROM EAST END OF FIR DOWN TO WEST END OF FIR DOWN *BASEMENT BED NEEDS TO BE ON ARCH FAULT BREAKER
Final Inspection - Residential Passed 2/25/2020 2/25/2020 02/25/2020
Rough Electrical Inspection - Residential Passed 02/25/2020
Rough Mechanical Inspection - Residential Passed 02/25/2020
Underslab Plumbing Inspection - Residential Passed 02/25/2020
Rough Plumbing Inspection - Residential Passed 02/25/2020
Documents & Images
Date Uploaded File Type Document Name
07/10/2018 Receipt Receipt for transaction: 2018-004783
07/10/2018 Letter Codes Building Permit
07/11/2018 Scope of Work DOC071118-07112018092447
07/11/2018 Drawing DOC071118-07112018092503
01/18/2019 Letter INSPECTION SUMMARY
01/29/2019 Letter INSPECTION SUMMARY
01/30/2019 Letter INSPECTION SUMMARY
02/25/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home