Permit Application Status

PRRES20182092


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20182092
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT COVERED DECK
07/06/2018
07/18/2018
10/03/2019
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
KC CUSTOM HOMES, Address:406 NW DONOVAN RD, Phone:(816) 564-5149  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 07/10/2018 07/17/2018
Brandon Kalwei
19 Footings, column pads, piers and grade beams - dimensions
Corrective Action Required
07/06/2018

Footings, column pads, piers and grade beams - dimensions. (IRC Section R403)Not entirely sure for the garage pads and pier pads in basement on where details are located
20 Footings, column pads, piers and grade beams - reinforcement
Corrective Action Required
07/06/2018

Footings, column pads, piers and grade beams - reinforcement size and spacing. Not entirely sure for the garage pads and pier pads in basement on where details are located
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
07/06/2018

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) cannot find details for 11' ceiling heights.
Misc
Corrective Action Required
07/06/2018

Please provide address of property on constructin drawings.
Misc
Corrective Action Required
07/06/2018

Electrical contractor will need to renew his business license before permit can be issured.
Plot Plan Review Approved 07/10/2018 07/10/2018
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,072.77 $1,072.77 Paid 07/18/2018
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/18/2018
8331504-EFHB Middle Big Creek, Full $569.16 $569.16 Paid 07/18/2018
8331507-Sewer Connection Fee $510.00 $510.00 Paid 07/18/2018
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 07/18/2018
8350015-Water Meter Fee $408.37 $408.37 Paid 07/18/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 7/18/2018 7/18/2018 at 3:15 PM 07/18/2018
Underslab Plumbing Inspection - Residential Passed 8/17/2018 8/17/2018 at 8:30 AM 08/17/2018
Sewer Service Inspection - R Passed 9/25/2018 (9:15) 9/25/2018 at 10:00 AM 09/25/2018
Water Service Inspection - R Passed 9/25/2018 9/25/2018 at 3:30 PM 09/25/2018
All Rough Inspection - Residential Failed 12/28/2018 12/28/2018
Misc
Corrective Action Required
12/28/2018
-plumbing protection plate east wall front bedroom . -security blocking at sliding door , mstr bedroom door etc. -firestop fireplace from attic over mstr, each side of firepalce over builtins. -vent all bath fans and firestop penetrations. -install rear slider. -install floor box at rear great room. -install floor outlets along stair opening per code. -firestop dbl wall at star/ garage wall. - fire stop dbl bsmt walls east side 10' horizontal. - firestop over bsmt window NE bedroom from josit space. - firestop bathroom at ceiling height with 3/4" or 2x4 material. -plumbing protection plates NE bsmt bedroom at bath wall. -anchor bsmt beam posts. -firestop all tub shower traps. - holes drilled in bottom 2" over josit over bar sink and NW bsmt bath.
Electrical Service Inspection Passed 12/28/2018 12/28/2018
Gas Service Inspection - Residential Passed 12/28/2018 12/28/2018
Erosion Control Inspection Residential Failed 12/28/2018
All Rough Inspection - Residential Failed 1/17/2019 1/17/2019 at 10:15 AM 01/17/2019
Misc
Partial Correction
01/17/2019
-plumbing protection plate east wall front bedroom . -install floor box at rear great room. -install floor outlets along stair opening per code. -firestop dbl wall at stair/ garage wall. - firestop over bsmt window NE bedroom from josit space. -plumbing protection plates NE bsmt bedroom at bath wall. -firestop all tub shower traps. - holes drilled in bottom 2" josit over bar sink and NW bsmt bath.
All Rough Inspection - Residential Passed 1/25/2019 1/25/2019 at 12:00 PM 01/25/2019
Misc
Resolved
01/25/2019
-plumbing protection plate east wall front bedroom . -install floor box at rear great room. -install floor outlets along stair opening per code. -firestop dbl wall at stair/ garage wall. - firestop over bsmt window NE bedroom from josit space. -plumbing protection plates NE bsmt bedroom at bath wall. -firestop all tub shower traps. - holes drilled in bottom 2" josit over bar sink and NW bsmt bath.
Piers/Caissons Inspection - Residential Failed 4/2/2019 4/2/2019 04/02/2019
Misc
Corrective Action Required
04/02/2019
Piers full of water
Driveway Inspection Partial 4/5/2019 4/5/2019 04/05/2019
Misc
Informational
04/05/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 4/5/2019 4/5/2019 04/05/2019
Misc
Informational
04/05/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 4/10/2019 04/11/2019
Misc
Informational
04/05/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 4/10/2019 04/11/2019
Misc
Informational
04/05/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 9/30/2019 9/30/2019 09/30/2019
Misc
Corrective Action Required
09/30/2019
- Seal all outside electrical fixtures, penetrations, etc - gfci in garage not working properly - hammer arrestors needed for clothes washer - C/o detector needed outside of downstairs bedrooms, need to Verify that upstairs detectors are C/o as well - gfci outlets in jack and Jill bathroom in basement are not working properly - need to Sheetrock underneath stairs in unfinished basement -outside GFCI by ac unit not working properly
Occupancy Inspection - Codes Residential Failed 10/2/2019 10/2/2019 10/02/2019
Misc
Partial Correction
10/02/2019
- Seal all outside electrical fixtures, penetrations, etc - gfci in garage not working properly - hammer arrestors needed for clothes washer - C/o detector needed outside of downstairs bedrooms, need to Verify that upstairs detectors are C/o as well - gfci outlets in jack and Jill bathroom in basement are not working properly - need to Sheetrock underneath stairs in unfinished basement -outside GFCI by ac unit not working properly
Misc
Corrective Action Required
10/02/2019
- Seal all outside electrical fixtures, penetrations, etc - hammer arrestors needed for clothes washer
Occupancy Inspection - Codes Residential Full C of O 10/3/2019 10/3/2019 10/03/2019
Misc
Resolved
10/03/2019
- Seal all outside electrical fixtures, penetrations, etc - gfci in garage not working properly - hammer arrestors needed for clothes washer - C/o detector needed outside of downstairs bedrooms, need to Verify that upstairs detectors are C/o as well - gfci outlets in jack and Jill bathroom in basement are not working properly - need to Sheetrock underneath stairs in unfinished basement -outside GFCI by ac unit not working properly
Misc
Resolved
10/03/2019
- Seal all outside electrical fixtures, penetrations, etc - hammer arrestors needed for clothes washer
Documents & Images
Date Uploaded File Type Document Name
07/06/2018 Letter Codes Residential Plan Review
07/18/2018 Receipt Receipt for transaction: 2018-004954
07/18/2018 Letter Codes Building Permit
07/18/2018 Letter Inspection Summary
07/18/2018 Plot Plan DOC071818-07182018141739
08/17/2018 Letter Inspection Summary
08/17/2018 Letter Inspection Summary
09/25/2018 Letter Inspection Summary
09/25/2018 Letter Inspection Summary
12/28/2018 Letter INSPECTION SUMMARY
01/17/2019 Letter INSPECTION SUMMARY
01/25/2019 Letter INSPECTION SUMMARY
04/02/2019 Letter INSPECTION SUMMARY
04/05/2019 Letter INSPECTION SUMMARY
04/05/2019 Letter INSPECTION SUMMARY
04/11/2019 Letter INSPECTION SUMMARY
04/11/2019 Letter INSPECTION SUMMARY
04/11/2019 Letter INSPECTION SUMMARY
09/30/2019 Letter INSPECTION SUMMARY
10/02/2019 Letter INSPECTION SUMMARY
10/03/2019 Letter Field Certificate of Occupancy
10/03/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home