Permit Application Status

PRRES20181762


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20181762
Building Permit - Residential
Certificate of Occupancy
JFE CONSTRUCTION INC
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT COVERED DECK
06/08/2018
06/18/2018
04/23/2019
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
MOOSE ELECTRICAL CONSTRUCTION LLC, Address:105 HARLEQUIN DR, Phone:(816) 682-2693  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 06/12/2018 06/15/2018
Brandon Kalwei
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
06/08/2018

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) unfinished basement sf. not found.
06 Designate use of each room or space
Corrective Action Required
06/08/2018

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. - the upper level room is labeled office and i believe it needs to bedroom #2
Plot Plan Review Approved 06/13/2018 06/14/2018
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $842.46 $842.46 Paid 06/18/2018
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 06/18/2018
8331507-Sewer Connection Fee $420.00 $420.00 Paid 06/18/2018
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 06/18/2018
8350015-Water Meter Fee $431.83 $431.83 Paid 06/18/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/3/2018 7/3/2018 at 8:00 AM 07/03/2018
Sewer Service Inspection - R Passed 7/17/2018 7/17/2018 at 8:00 AM 07/17/2018
Water Service Inspection - R Partial 7/17/2018 7/17/2018 at 8:20 AM 07/17/2018
Water Service Inspection - R Passed 7/18/2018 (11:00) 7/18/2018 07/18/2018
Underslab Plumbing Inspection - Residential Passed 7/20/2018 7/20/2018 07/20/2018
Piers/Caissons Inspection - Residential Failed 8/9/2018 (1:00) 8/9/2018 at 1:30 PM 08/09/2018
Misc
Corrective Action Required
08/09/2018
- REMOVE LOOSE DIRT FROM 2 HOLES TO THE NORTH
Piers/Caissons Inspection - Residential Passed 8/10/2018 (8:00) 8/10/2018 at 8:30 AM 08/10/2018
Misc
Corrective Action Required
08/09/2018
- REMOVE LOOSE DIRT FROM 2 HOLES TO THE NORTH
Electrical Service Inspection Passed 11/6/2018 11/6/2018 at 7:00 AM 11/06/2018
Gas Service Inspection - Residential Failed 11/6/2018 11/6/2018 at 8:00 AM 11/06/2018
All Rough Inspection - Residential Failed 11/6/2018 11/6/2018 at 8:10 AM 11/06/2018
Misc
Corrective Action Required
11/06/2018
- No psi -Joist hanger joist at stairs to lvl. -stair wall install studs directly under joist where wall is built with single top plate. -Fire stop dbl wall at bedroom and bathroom, dead space at shower. -Firestop dbl wall at south bedroom from joist space and 10' horizontal. -Firestop Drop ceiling rear bsmt walls. -Security blocking. -Joist hanger joist and lvl under fireplace. -Brace LVL in ceiling/attic per plan. -Install braced wall CS-PF breakfast room. -Install ridge legs over garage to I beam. -Provide 30” clearance over attic access. -install Garage door straps. -Fire stop laundry room wall at plates line height , same over shower and bedroom closet . -Strap top plates at mstr closet front porch wall. -Brace lvl over breakfast room. Support rafters to lvl install hanger or ledger under notched rafters. -Install Purlin in same rafters . Support ridge over kitchen wall. Roof area not framed per plans . -Fire stop dead space right of refrigerator.
Gas Service Inspection - Residential Passed 11/12/2018 11/12/2018 11/12/2018
All Rough Inspection - Residential Failed 11/12/2018 11/12/2018 11/12/2018
Misc
Corrective Action Required
11/06/2018
-Firestop dbl wall at south bedroom from joist space and 10' horizontal. seal all penetrations. fire stopped with 1/2" not 3/4" -Brace lvl over breakfast room. brace the north end. -Fire stop dead space right of refrigerator. seal from attic
All Rough Inspection - Residential Passed 11/19/2018 11/19/2018 11/19/2018
Misc
Resolved
11/19/2018
-Firestop dbl wall at south bedroom from joist space and 10' horizontal. seal all penetrations. fire stopped with 1/2" not 3/4" -Brace lvl over breakfast room. brace the north end. -Fire stop dead space right of refrigerator. seal from attic
Driveway Inspection Partial 12/10/2018 12/10/2018 12/11/2018
Misc
Informational
12/11/2018
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 12/18/2018 12/18/2018
Misc
Informational
12/11/2018
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Temporary C of O 3/25/2019 3/25/2019 03/25/2019
Misc
Corrective Action Required
03/25/2019
- exterior items only: sod, erosion control needs to be installed asap. Water meter , final grade, splashblocks etc.
Occupancy Inspection - Codes Residential Full C of O 4/23/2019 4/23/2019 04/23/2019
Misc
Resolved
04/23/2019
- exterior items only: sod, erosion control needs to be installed asap. Water meter , final grade, splashblocks etc.
Documents & Images
Date Uploaded File Type Document Name
06/08/2018 Letter Codes Residential Plan Review
06/18/2018 Receipt Receipt for transaction: 2018-003956
06/18/2018 Letter Codes Building Permit
06/21/2018 Plot Plan DOC062118-06212018113716
07/03/2018 Letter Inspection Summary
07/17/2018 Letter Inspection Summary
07/18/2018 Letter Inspection Summary
07/20/2018 Letter Inspection Summary
08/09/2018 Letter Inspection Summary
08/10/2018 Letter Inspection Summary
11/06/2018 Letter Inspection Summary
11/12/2018 Letter Inspection Summary
11/19/2018 Letter INSPECTION SUMMARY
12/11/2018 Letter INSPECTION SUMMARY
12/18/2018 Letter DE-Daily Inspection Summary
03/25/2019 Letter Codes Temporary Certificate of Occupancy
04/23/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home