Permit Application Status

PRRES20181577


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20181577
Building Permit - Residential
Certificate of Occupancy
ASPEN HOMEBUILDERS LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
05/23/2018
05/31/2018
03/05/2020
Locations
Contacts
ASPEN HOME BUILDERS LLC, Address:6618 ROYAL ST #B, Phone:(816) 507-0123  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
ASPEN HOMEBUILDERS LLC, Address:6618 ROYAL ST STE B  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/30/2018 05/30/2018
Troy Thompson
Residential Plan Review Approved 05/25/2018 05/23/2018
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,021.07 $1,021.07 Paid 05/31/2018
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 05/31/2018
8331507-Sewer Connection Fee $570.00 $570.00 Paid 05/31/2018
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 05/31/2018
8350015-Water Meter Fee $431.83 $431.83 Paid 05/31/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/3/2018 8/3/2018 at 1:30 PM 08/03/2018
Underslab Plumbing Inspection - Residential Passed 9/5/2018 9/5/2018 at 7:00 AM 09/05/2018
Piers/Caissons Inspection - Residential Passed 3/21/2019 3/21/2019 03/21/2019
Gas Service Inspection - Residential Passed 5/7/2019 04/29/2019
Electrical Service Inspection Passed 5/7/2019 05/07/2019
All Rough Inspection - Residential Failed 5/7/2019 5/7/2019 05/07/2019
Misc
Corrective Action Required
05/07/2019
- Rear wall CS-PF install or engineer fix. - firestop rear wall at fur down - notched joist for 3" rear wall 1st floor - fire stop garage wall and flue chase 1st floor from vertical to horizontal. -flue clearance 2nd floor - support Ridge and valley over north bedroom 2nd floor -strap braced wall mud room cut at the bottom plate. -install secuirty blocking
Sewer Service Inspection - R Failed 5/8/2019 5/8/2019 05/08/2019
Misc
Corrective Action Required
05/08/2019
Trench caved in and was covered up
Water Service Inspection - R Failed 5/8/2019 5/8/2019 05/08/2019
Misc
Corrective Action Required
05/08/2019
Trench caved in and was covered up
Sewer Service Inspection - R Passed 5/8/2019 5/8/2019 at 1:30 PM 05/08/2019
Misc
Resolved
05/08/2019
Trench caved in and was covered up
Water Service Inspection - R Partial 5/8/2019 5/8/2019 at 1:46 PM 05/08/2019
Misc
Corrective Action Required
05/08/2019
Trench caved in and was covered up
Water Service Inspection - R Passed 5/13/2019 (1:00) 5/13/2019 at 1:40 AM 05/13/2019
Misc
Resolved
05/13/2019
Trench caved in and was covered up
All Rough Inspection - Residential Passed 5/17/2019 5/17/2019 05/17/2019
Misc
Resolved
05/17/2019
Driveway Inspection Partial 6/28/2019 6/28/2019 at 1:45 PM 06/28/2019
Informational
06/28/2019
John DiMauro 06/28/2019 2:42 PM PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 7/3/2019 07/03/2019
Investigation Inspection Complete 12/30/2019 12/30/2019
Occupancy Inspection - Codes Residential Full C of O 3/5/2020 3/5/2020 03/05/2020
Misc
Resolved
03/05/2020
Documents & Images
Date Uploaded File Type Document Name
05/31/2018 Receipt Receipt for transaction: 2018-003338
05/31/2018 Letter Codes Building Permit
06/01/2018 Plot Plan DOC060118-019
08/03/2018 Letter Inspection Summary
09/05/2018 Letter Inspection Summary
03/21/2019 Letter INSPECTION SUMMARY
05/07/2019 Letter INSPECTION SUMMARY
05/08/2019 Letter INSPECTION SUMMARY
05/08/2019 Letter INSPECTION SUMMARY
05/08/2019 Letter INSPECTION SUMMARY
05/08/2019 Letter INSPECTION SUMMARY
05/08/2019 Letter INSPECTION SUMMARY
05/13/2019 Letter INSPECTION SUMMARY
05/17/2019 Letter INSPECTION SUMMARY
06/28/2019 Letter DE-Daily Inspection Summary
07/03/2019 Letter INSPECTION SUMMARY
07/03/2019 Letter INSPECTION SUMMARY
03/05/2020 Letter Field Certificate of Occupancy
03/05/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home