Permit Application Status

PRRES20181393


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20181393
Building Permit - Residential
Certificate of Occupancy
MAR INVESTMENTS INC
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT COVERED DECK
05/07/2018
05/29/2018
05/30/2019
Locations
Contacts
MAR INVESTMENTS INC, Address:PO BOX 847  
KC CUSTOM HOMES, Address:406 NW DONOVAN RD, Phone:(816) 564-5149  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/09/2018 05/09/2018
Steve Conrick
As-graded plot plan
Corrective Action Required
05/09/2018

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. ***Please put in a bubble "AS GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING."
Spot elevations
Corrective Action Required
05/09/2018

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. ***SE corner of the building to the SW property corner is less that 2% slope. Please provide additional spot elevations or contours.***
Residential Plan Review Approved 05/09/2018 05/09/2018
Brandon Kalwei
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
05/08/2018

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) - no carbon/ smoke for bedroom #2
10 Combustion air
Corrective Action Required
05/08/2018

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $886.34 $886.34 Paid 05/29/2018
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 05/29/2018
8331504-EFHB Middle Big Creek, Full $569.16 $569.16 Paid 05/29/2018
8331507-Sewer Connection Fee $510.00 $510.00 Paid 05/29/2018
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 05/29/2018
8350015-Water Meter Fee $431.83 $431.83 Paid 05/29/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/1/2018 6/1/2018 at 3:15 AM 06/01/2018
Underslab Plumbing Inspection - Residential Passed 7/6/2018 at 8:00 AM 07/06/2018
Sewer Service Inspection - R Passed 7/6/2018 7/6/2018 at 10:30 AM 07/06/2018
Water Service Inspection - R Passed 7/9/2018 7/9/2018 at 10:40 AM 07/09/2018
Piers/Caissons Inspection - Residential Passed 9/4/2018 at 8:20 AM 09/04/2018
Electrical Service Inspection Passed 10/18/2018 10/18/2018 at 9:30 AM 10/18/2018
Gas Service Inspection - Residential Passed 10/18/2018 10/18/2018 at 9:41 AM 10/18/2018
All Rough Inspection - Residential Failed 10/18/2018 10/18/2018 at 9:50 AM 10/18/2018
Misc
Corrective Action Required
10/18/2018
* NO CITY APPROVED PLANS ON SIGHT*
Gas Piping Inspection - Residential Failed 10/23/2018
Misc
Corrective Action Required
10/23/2018
Gas line not connected at fireplace * 0 PSI IN GAS LINE
All Rough Inspection - Residential Failed 10/23/2018 at 8:41 AM 10/23/2018
Misc
Resolved
10/23/2018
* NO CITY APPROVED PLANS ON SIGHT*
Misc
Corrective Action Required
10/23/2018
• fire block spaces left and right of fireplace from fireplace space • Exhaust all bath fans on main floor • Connect gas line at fireplace • Fire block entire east wall in basement from joist space from back of the house to the panel • Exhaust all bath fans in basement • Fire block entire west wall in basement from joist space from back of house to front • Fire block south wall at sliding glass doors in basement from fir down space • Fire block north wall from fir down space in basement at fir down left of stairs • Fire stop gap at north wall basement • Fire block left of windows in basement at fir down • No lags or ledger locks at deck • •
Gas Piping Inspection - Residential Passed 10/26/2018 10/26/2018 at 9:00 AM 10/26/2018
Misc
Corrective Action Required
10/23/2018
Gas line not connected at fireplace * 0 PSI IN GAS LINE
All Rough Inspection - Residential Passed 10/26/2018 10/26/2018 at 9:06 AM 10/26/2018
Misc
Resolved
10/26/2018
• fire block spaces left and right of fireplace from fireplace space • Exhaust all bath fans on main floor • Connect gas line at fireplace • Fire block entire east wall in basement from joist space from back of the house to the panel • Exhaust all bath fans in basement • Fire block entire west wall in basement from joist space from back of house to front • Fire block south wall at sliding glass doors in basement from fir down space • Fire block north wall from fir down space in basement at fir down left of stairs • Fire stop gap at north wall basement • Fire block left of windows in basement at fir down • No lags or ledger locks at deck • •
Sidewalk Inspection Partial 11/19/2018 11/19/2018
Misc
Informational
11/19/2018
Pre pour inspection. The forms are up and there appears to be sufficient compacted aggregate.
Driveway Inspection Partial 11/19/2018 11/19/2018
Misc
Informational
11/19/2018
Pre pour inspection. The forms are up and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 11/30/2018 12/03/2018
Misc
Informational
11/19/2018
Pre pour inspection. The forms are up and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 11/30/2018 12/03/2018
Misc
Informational
11/19/2018
Pre pour inspection. The forms are up and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 2/11/2019 2/11/2019 at 7:30 AM 02/11/2019
Misc
Corrective Action Required
02/11/2019
Install shower enclosure at master bath. Install shower enclosure at guest bath main floor. Install ledger locks or equivalent lag bolts at deck ledger board. Open electric box in master bath. Lockouts on oven and micro breakers Final grading Sod. splash blocks provide as graded plot plan prior to sodding
Occupancy Inspection - Codes Residential Temporary C of O 2/14/2019 2/14/2019 at 11:00 AM 02/14/2019
Misc
Resolved
02/14/2019
Install shower enclosure at master bath. Install shower enclosure at guest bath main floor. Install ledger locks or equivalent lag bolts at deck ledger board. Open electric box in master bath. Lockouts on oven and micro breakers Final grading Sod. splash blocks provide as graded plot plan prior to sodding
Misc
Corrective Action Required
02/14/2019
Final grading Sod. splash blocks provide as graded plot plan prior to sodding
Occupancy Inspection - Codes Residential Temporary C of O 5/21/2019 at 7:45 AM 05/21/2019
Misc
Resolved
05/21/2019
Final grading Sod. splash blocks provide as graded plot plan prior to sodding
Misc
Resolved
05/30/2019
SPLASH BLOKS PROVIDE AS GRADED PLOT PLAN
Occupancy Inspection - Codes Residential Full C of O 5/30/2019 5/30/2019 at 11:01 AM 05/30/2019
Misc
Corrective Action Required
05/21/2019
SPLASH BLOKS PROVIDE AS GRADED PLOT PLAN
Documents & Images
Date Uploaded File Type Document Name
05/08/2018 Letter Codes Residential Plan Review
05/09/2018 Letter Codes Residential Plan Review
05/29/2018 Receipt Receipt for transaction: 2018-003160
05/29/2018 Letter Codes Building Permit
05/29/2018 DOC052918-001
07/06/2018 Letter Inspection Summary
07/06/2018 Letter Inspection Summary
07/09/2018 Letter Inspection Summary
09/04/2018 Letter Inspection Summary
10/18/2018 Letter Inspection Summary
10/23/2018 Letter Inspection Summary
10/26/2018 Letter Inspection Summary
10/26/2018 Letter Inspection Summary
11/19/2018 Letter INSPECTION SUMMARY
11/19/2018 image
11/19/2018 Letter INSPECTION SUMMARY
12/03/2018 Letter INSPECTION SUMMARY
12/03/2018 Letter INSPECTION SUMMARY
02/11/2019 Letter INSPECTION SUMMARY
02/14/2019 Letter Codes Temporary Certificate of Occupancy
05/21/2019 Letter Codes Temporary Certificate of Occupancy
05/30/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home