Permit Application Status

PRRES20180307


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20180307
Building Permit - Residential
Certificate of Occupancy
KEVIN HIGDON CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE UNFINISHED BASEMENT
02/12/2018
02/13/2018
10/01/2018
Locations
Contacts
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/14/2018 02/13/2018
Troy Thompson
Residential Plan Review Approved 02/14/2018 02/12/2018
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,229.05 $1,229.05 Paid 02/13/2018
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 02/13/2018
8331504-EFHB Middle Big Creek, Full $636.12 $636.12 Paid 02/13/2018
8331507-Sewer Connection Fee $570.00 $570.00 Paid 02/13/2018
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 02/13/2018
8350015-Water Meter Fee $431.83 $431.83 Paid 02/13/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/27/2018 at 3:25 PM 02/27/2018
Underslab Plumbing Inspection - Residential Not Ready 3/14/2018 3/14/2018 at 10:25 AM 03/14/2018
Corrective Action Required
03/14/2018
NO ACCESS FOR INSPECTION
Underslab Plumbing Inspection - Residential Passed 3/23/2018 3/23/2018 03/23/2018
Erosion Control Inspection Residential Failed 4/3/2018 at 2:00 PM 04/03/2018
Corrective Action Required
04/03/2018
Matt Munger 04/03/2018 2:13 PM The ESC devices are not in compliance. The gravel and silt that has been tracked into the street will need to be removed.
Sewer Service Inspection - R Passed 4/4/2018 4/4/2018 at 10:10 AM 04/04/2018
Water Service Inspection - R Passed 4/5/2018 at 2:00 PM 04/05/2018
Gas Piping Inspection - Residential Passed 5/25/2018 5/25/2018 at 10:15 AM 05/25/2018
All Rough Inspection - Residential Not Ready 6/18/2018 at 2:30 PM 06/18/2018
Misc
Corrective Action Required
06/18/2018
-erosion control - lean street - carpenters still working
Gas Service Inspection - Residential Passed 6/18/2018 6/18/2018 at 3:00 PM 06/18/2018
All Rough Inspection - Residential Failed 6/21/2018 6/21/2018 at 8:00 AM 06/21/2018
Misc
Corrective Action Required
06/18/2018
-erosion control - lean street - carpenters still working
Electrical Service Inspection Passed 6/21/2018 6/21/2018 at 8:46 AM 06/21/2018
Misc
Corrective Action Required
06/21/2018
1. Fire stopping needed in garage at ceiling 2. Missing anchor bolts at splices in garage need to be withing 12 inches either side of splice 3. Over notched studs in garage 4. Fire stopping needed in 1st floor bathroom 5. Fire stopping needed in pantry 6. Water line in kitchen needs to be moved or protected 7. Missing bolts in filler for I beam 8. Add floor joist hangers on floor joist in entryway 9. Protec wires behind and on side of fireplace in master bedroom 10 Connect exhaust duct in Master bathroom 11 Firestopping need in utility room on 2nd floor
All Rough Inspection - Residential Not Ready 6/27/2018 6/27/2018 06/27/2018
Misc
Corrective Action Required
06/21/2018
-erosion control - lean street - carpenters still working
All Rough Inspection - Residential Failed 6/28/2018 6/28/2018 at 9:10 AM 06/28/2018
Misc
Corrective Action Required
06/27/2018
-erosion control - lean street - carpenters still working
All Rough Inspection - Residential Failed 06/28/2018
Misc
Corrective Action Required
06/28/2018
-erosion control - lean street - carpenters still working
R602.8 Fireblocking required
Corrective Action Required
06/28/2018
1. fireblocking has not been completed. WOOD WALL FRAMING. Fireblocking shall be provided to cut off all concealed draft openings (both vertical and horizontal) and to form an effective fire barrier between stories, and between a top story and the roof space. Fireblocking shall be provided in wood-frame construction in the following locations. 1. In concealed spaces of stud walls and partitions, including furred spaces and parallel rows of studs or staggered studs; as follows: 1.1. Vertically at the ceiling and floor levels. 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm). 2. At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings. 3. In concealed spaces between stair stringers at the top and bottom of the run. Enclosed spaces under stairs shall comply with Section R311.2.2. 4. At openings around vents, pipes, ducts, cables and wires at ceiling and floor level, with an approved material to resist the free passage of flame and products of combustion. 5. For the fireblocking of chimneys and fireplaces, see Section R1003.19. 6. Fireblocking of cornices of a two-family dwelling is required at the line of dwelling unit separation. 2. Over notched stud in garage 3. Missing bolts in filler for I beam at bay window 1st floor
All Rough Inspection - Residential Failed 7/3/2018 7/3/2018 at 10:00 AM 07/03/2018
Misc
Resolved
07/03/2018
-erosion control - lean street - carpenters still working
R602.8 Fireblocking required
Resolved
07/03/2018
1. fireblocking has not been completed. WOOD WALL FRAMING. Fireblocking shall be provided to cut off all concealed draft openings (both vertical and horizontal) and to form an effective fire barrier between stories, and between a top story and the roof space. Fireblocking shall be provided in wood-frame construction in the following locations. 1. In concealed spaces of stud walls and partitions, including furred spaces and parallel rows of studs or staggered studs; as follows: 1.1. Vertically at the ceiling and floor levels. 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm). 2. At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings. 3. In concealed spaces between stair stringers at the top and bottom of the run. Enclosed spaces under stairs shall comply with Section R311.2.2. 4. At openings around vents, pipes, ducts, cables and wires at ceiling and floor level, with an approved material to resist the free passage of flame and products of combustion. 5. For the fireblocking of chimneys and fireplaces, see Section R1003.19. 6. Fireblocking of cornices of a two-family dwelling is required at the line of dwelling unit separation. 2. Over notched stud in garage 3. Missing bolts in filler for I beam at bay window 1st floor
Misc
Corrective Action Required
07/03/2018
1. overnotched stud in garage 2. clean street
All Rough Inspection - Residential Failed 7/5/2018 7/5/2018 at 10:05 AM 07/05/2018
Misc
Corrective Action Required
07/03/2018
1. overnotched stud in garage 2. clean street
Misc
Corrective Action Required
07/05/2018
1. OVER NOTCHED STUD ON HOUSE EAST SIDE OF GARAGE
Driveway Inspection Partial 8/9/2018 8/9/2018 at 1:30 PM 08/09/2018
Informational
08/09/2018
Tom Chandler 08/09/2018 5:46 PM Inspected forms and compacted aggregate only.
Sidewalk Inspection Partial 8/9/2018 8/9/2018 at 1:35 PM 08/09/2018
Informational
08/09/2018
Tom Chandler 08/09/2018 5:47 PM Inspected forms and compacted aggregate only.
Plot Plan Inspection Passed 09/28/2018
Occupancy Inspection - Codes Residential Failed 9/28/2018 9/28/2018 at 2:10 PM 09/28/2018
Misc
Corrective Action Required
09/28/2018
• tighten outlet in garage nw • Smoke alarm in basement needs to be combination smoke/ carbon • Install box extension /spark arrestor at master fire place outlet • Smoke alarm in master bedroom needs to be a combination smoke/ carbon because of the fireplace • Driveway inspection needed • Sidewalk inspection needed
Driveway Inspection Passed 10/1/2018 at 2:30 PM 10/01/2018
Informational
10/01/2018
Tom Chandler 10/01/2018 2:34 PM Driveway has been completed and passed final inspection.
Sidewalk Inspection Passed 10/1/2018 at 2:35 PM 10/01/2018
Informational
10/01/2018
Tom Chandler 10/01/2018 2:35 PM Sidewalk has been completed and passed final inspection.
Occupancy Inspection - Codes Residential Full C of O 10/1/2018 10/1/2018 at 1:30 PM 10/01/2018
Documents & Images
Date Uploaded File Type Document Name
02/13/2018 Receipt Receipt for transaction: 2018-000532
02/13/2018 Letter Codes Building Permit
02/14/2018 Plot Plan DOC021418-006
02/27/2018 Letter Inspection Summary
03/23/2018 Letter Inspection Summary
04/03/2018 Letter DE-Daily Inspection Summary
04/04/2018 Letter Inspection Summary
04/05/2018 Letter Inspection Summary
05/25/2018 Letter Inspection Summary
06/18/2018 Letter Inspection Summary
06/21/2018 Letter Inspection Summary
06/27/2018 Letter Inspection Summary
06/28/2018 Letter Inspection Summary
07/03/2018 Letter Inspection Summary
07/05/2018 Letter Inspection Summary
08/09/2018 Letter DE-Daily Inspection Summary
09/28/2018 Letter Inspection Summary
10/01/2018 Letter DE-Daily Inspection Summary
10/01/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home