Summary
PRRES20173752
Building Permit - Residential
Closed
KEVIN HIDGON CONSTRUCTION LLC
ALTERATION SINGLE FAMILY
BASEMENT FINISH **NO FINAL INSPECTION PERFORMED, PERMIT EXPIRED AND CLOSED**
11/15/2017
11/15/2017
02/18/2021
Locations
Contacts
KEVIN HIDGON CONSTRUCTION LLC, Address:PO BOX 847  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
VAUGHN BLAKE & KELSIE, Address:1713 SW NAPA VALLEY DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 11/17/2017 11/15/2017
Development Center
Plot Plan Review Approved 11/15/2017
Development Center
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Add/Alter Single Family $100.93 $100.93 Paid 11/15/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Residential Failed 11/29/2017 11/29/2017 at 11:50 AM 11/29/2017
Misc
Corrective Action Required
11/29/2017
1. Firestop along tops of furred-out walls, at ends / along furred-down ceiling, at edge of stair landing, and vertically along furred-walls every 10'. 2. BOCA plate at top of 3" DWV, where it enters into joist space. 3. Extend water heater pressure relief discharge pipe. 4. If area under front porch is to be separated by a door, will need to provide a GFI-protected outlet inside the room.
All Rough Inspection - Residential Failed 11/30/2017 11/30/2017 at 1:10 AM 11/30/2017
Misc
Corrective Action Required
11/29/2017
1. Firestop along tops of furred-out walls, at ends / along furred-down ceiling, *still need at corner where furred-out wall meets stair, and at top of steel post by stair* --, and vertically along furred-walls every 10'. *boards have been put in place, but at greater than every 10', and only one of these has been foamed.* 3. Extend water heater pressure relief discharge pipe.
All Rough Inspection - Residential Failed 12/1/2017 12/1/2017 at 2:40 AM 12/01/2017
Misc
Corrective Action Required
11/30/2017
1. Firestop along tops of furred-out walls, at ends / along furred-down ceiling, *still need at corner where furred-out wall meets stair, and at top of steel post by stair* --, and vertically along furred-walls every 10'. *boards have been put in place, but at greater than every 10', and only one of these has been foamed.* **Boards are now every 10', but only a few have now been foamed. Still need to address the two locations near the stair.
All Rough Inspection - Residential Passed 12/4/2017 12/4/2017 at 9:50 AM 12/04/2017
Misc
Resolved
12/04/2017
1. Firestop along tops of furred-out walls, at ends / along furred-down ceiling, *still need at corner where furred-out wall meets stair, and at top of steel post by stair* --, and vertically along furred-walls every 10'. *boards have been put in place, but at greater than every 10', and only one of these has been foamed.* **Boards are now every 10', but only a few have now been foamed. Still need to address the two locations near the stair.
Documents & Images
Date Uploaded File Type Document Name
11/15/2017 Receipt Receipt for transaction: 2017-007292
11/15/2017 Letter Codes Building Permit
11/16/2017 Drawing DOC111617-005
11/29/2017 Letter Inspection Summary
11/30/2017 Letter Inspection Summary
12/01/2017 Letter Inspection Summary
12/04/2017 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home