Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 10/13/2017 10/17/2017
Development Center
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
10/11/2017

Identify roof covering material (IRC Section R905)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
10/11/2017

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Plot Plan Review Approved 10/13/2017 10/11/2017
Nick Lightner
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,247.42 $1,247.42 Paid 10/17/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 10/17/2017
8331504-EFHB Middle Big Creek, Full $636.12 $636.12 Paid 10/17/2017
8331507-Sewer Connection Fee $570.00 $570.00 Paid 10/17/2017
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 10/17/2017
8350015-Water Meter Fee $431.83 $431.83 Paid 10/17/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/27/2017 (11:30) 10/27/2017 at 11:50 AM 10/27/2017
Underslab Plumbing Inspection - Residential Passed 11/20/2017 11/20/2017 at 12:05 PM 11/20/2017
Sewer Service Inspection - R Partial 1/25/2018 (2:00) 1/25/2018 at 3:20 PM 01/25/2018
Misc
Partial Correction
01/25/2018
APPROVED TO FRONT OF THE HOUSE
Water Service Inspection - R Partial 1/25/2018 at 3:26 PM 01/25/2018
Sewer Service Inspection - R Passed 1/26/2018 (9:45) 1/26/2018 at 11:00 AM 01/26/2018
Misc
Resolved
01/26/2018
APPROVED TO FRONT OF THE HOUSE
Water Service Inspection - R Passed 1/26/2018 at 11:15 AM 01/26/2018
All Rough Inspection - Residential Failed 1/31/2018 1/31/2018 at 12:00 PM 01/31/2018
Misc
Corrective Action Required
01/31/2018
1. Fireblock fur downs garage. 2. Header and hanger floor joist over garage. 3. Nail garage portal frame 3” o.c. 4. Stud shoe plumbing garage cold wall. 5. Solid block ends floor joists over beams and front cantilever. 6. Security block walkout door. 7. Deck, post will be required for bearing at both ends. 8. Fireblock change ceiling elevation front bedroom. 9. Stud shoes all plumbing 2nd floor. 10. Interior braced wall line, next to stair, install let in brace.
Gas Service Inspection - Residential Passed 1/31/2018 1/31/2018 at 1:01 PM 01/31/2018
Electrical Service Inspection Passed 1/31/2018 1/31/2018 at 1:11 PM 01/31/2018
All Rough Inspection - Residential Passed 2/8/2018 2/8/2018 at 8:45 AM 02/08/2018
Misc
Resolved
02/08/2018
1. Fireblock fur downs garage. 2. Header and hanger floor joist over garage. 3. Nail garage portal frame 3” o.c. 4. Stud shoe plumbing garage cold wall. 5. Solid block ends floor joists over beams and front cantilever. 6. Security block walkout door. 7. Deck, post will be required for bearing at both ends. 8. Fireblock change ceiling elevation front bedroom. 9. Stud shoes all plumbing 2nd floor. 10. Interior braced wall line, next to stair, install let in brace.
Piers/Caissons Inspection - Residential Passed 2/28/2018 2/28/2018 at 1:00 PM 02/28/2018
Driveway Inspection Partial 2/28/2018 2/28/2018 at 2:30 PM 03/01/2018
Informational
03/01/2018
Tom Chandler 03/01/2018 8:43 AM Inspected forms and compacted aggregate only.
Sidewalk Inspection Failed 3/1/2018 at 2:15 PM 03/01/2018
Informational
03/01/2018
Tom Chandler 03/01/2018 2:30 PM Inspected forms and compacted aggregate only. ADA landing that was installed with the developement is not compliant. Will need to remove and replace. There are a couple of areas that I marked in paint that not compliant for cross slope. Contractor to make corrections and will reinspect in the morning. Called contractor to notify that corrections are needed.
Informational
03/02/2018
Tom Chandler 03/02/2018 10:22 AM Corrections have been made and ready to pour.
Sidewalk Inspection Partial 3/2/2018 at 8:00 AM 03/02/2018
Informational
03/02/2018
Tom Chandler 03/02/2018 10:19 AM Forms have been corrected and landing was removed and will be replaced with the sidewalk. Existing landing did not meet ADA requirements. This was installed with the developement.
Driveway Inspection Passed 3/5/2018 at 1:40 PM 03/05/2018
Informational
03/05/2018
Tom Chandler 03/05/2018 1:51 PM Driveway has been completed and passed final inspection.
Sidewalk Inspection Passed 3/5/2018 at 1:45 PM 03/05/2018
Informational
03/05/2018
Tom Chandler 03/05/2018 1:52 PM Sidewalk has been completed and passed final inspection.
Occupancy Inspection - Codes Residential Not Ready 5/22/2018 5/22/2018 at 2:00 PM 05/21/2018
Occupancy Inspection - Codes Residential Temporary C of O 5/24/2018 5/24/2018 at 7:20 AM 05/24/2018
Misc
Corrective Action Required
05/24/2018
1.BATHROOM FAUCIT IN 1ST BEDROOM ON THE LEFT HAS THE HOT AND COLD WATER ON WRONG SIDE 2. CARPETING MISSING ON STAIRS 3. HANDRAILS LEADING TO 2ND FLOOR NEED TO EXTEND TO THE NOSE OF THE FIRST TREAD
Occupancy Inspection - Codes Residential Full C of O 10/12/2020
Misc
Resolved
10/12/2020
Documents & Images
Date Uploaded File Type Document Name
10/11/2017 Letter Codes Residential Plan Review
10/17/2017 Receipt Receipt for transaction: 2017-006839
10/17/2017 Letter Codes Building Permit
10/17/2017 Plans DOC101717-007
11/20/2017 Letter Inspection Summary
01/25/2018 Letter Inspection Summary
01/26/2018 Letter Inspection Summary
01/31/2018 Letter Inspection Summary
02/08/2018 Letter Inspection Summary
02/28/2018 Letter Inspection Summary
03/01/2018 Letter DE-Daily Inspection Summary
03/01/2018 Letter DE-Daily Inspection Summary
03/02/2018 Letter DE-Daily Inspection Summary
03/05/2018 Certificate/License DE-Daily Inspection Summary
05/21/2018 Letter Inspection Summary
05/24/2018 Letter Codes Temporary Certificate of Occupancy
10/15/2018 Letter Codes 140 Day Letter
05/03/2019 Letter Codes 140 Day Letter
10/12/2020 Letter Field Certificate of Occupancy
10/12/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home