Summary
PRRES20173141
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - FINISHED BASEMENT
09/19/2017
10/05/2017
09/17/2018
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:1248 SW WYSTERIA DR  
DAVE RICHARDS HOMEBUILDING INC, Address:605 SW US HIGHWAY 40 #414, Phone:(816) 365-8034  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/21/2017 09/28/2017
Nick Lightner
North arrow and scale
Resolved
09/28/2017

The plot plan must be submitted on either (1) 81/2” x 11”, (2) 81/2”x 14”, or (3) 11” x 17” paper. All information on the plot plan must be drawn to scale. Scale must be 1” = 10’, 20’, or 30’; smaller scales that are multiples of the preceding scales may be used if necessary to represent large sites. All information on the plot plan must be clearly legible.) *Plot plan is not to scale. I will double check drainage later when a plot plan comes in that is to scale.
Property boundary
Informational
09/28/2017

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. *Can you please double check the rear lot property boundary. Plat shows them not combined.
Rear yard dimension
Resolved
09/28/2017

The rear yard demision(s) must be provided on the plot plan. *Rear yard doesnt meet setback due to the covered deck. Can you please double check.
Basement elevation
Resolved
09/28/2017

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) *Plot plan shows a walkout basement, but the MDP is calling out a daylight basement. Can you please double check and correct if needed.
Basement opening elevations
Resolved
09/28/2017

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. *Can you please add the MBOE to the plot plan.
Residential Plan Review Approved 09/21/2017 09/20/2017
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
09/19/2017

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) in the master bedroom and bedroom #2
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
09/19/2017

Identify roof covering material (IRC Section R905)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
09/19/2017

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $934.40 $934.40 Paid 10/05/2017
Right of Way Permit Fee $75.00 $75.00 Paid 10/05/2017
8331507-Sewer Connection Fee $360.00 $360.00 Paid 10/05/2017
Water Tap Fee $3,343.00 $3,343.00 Paid 10/05/2017
Water Meter Fee $431.83 $431.83 Paid 10/05/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/19/2017 (1:45) 10/19/2017 at 2:40 PM 10/19/2017
Underslab Plumbing Inspection - Residential Passed 11/9/2017 11/9/2017 at 8:35 AM 11/09/2017
All Rough Inspection - Residential Partial 1/26/2018 1/26/2018 at 10:00 AM 01/26/2018
Misc
Corrective Action Required
01/26/2018
GARAGE PORTAL WALL FRAMING-OK
Sewer Service Inspection - R Passed 2/12/2018 (2:30) 2/12/2018 02/14/2018
Water Service Inspection - R Passed 2/14/2018 at 3:15 PM 02/14/2018
Gas Service Inspection - Residential Passed 2/15/2018 2/15/2018 02/15/2018
Electrical Service Inspection Passed 2/15/2018 2/15/2018 02/15/2018
Piers/Caissons Inspection - Residential Passed 2/15/2018 2/15/2018 02/15/2018
All Rough Inspection - Residential Failed 2/15/2018 2/15/2018 at 9:10 AM 02/15/2018
Misc
Corrective Action Required
01/26/2018
FRAMING: -Nail siding per code -Install collar ties -Fb fireplace space from roof -Support vent above master bath -Fb basement wall per code (vertically every ten ft and from ceiling space) -Install beam under point loads at foyer ELECTRICAL: -Protect wiring within six ft of attic access -Protect range circuit at master toilet -Wall receptacle spacing per code rear basement bedroom -Support and protect wiring per code along I beam in basement PLUMBING: -Protect plumbing at kitchen and pantry ***OK TO INSULATE
All Rough Inspection - Residential Failed 2/20/2018 at 8:15 AM 02/20/2018
Misc
Corrective Action Required
02/15/2018
FRAMING: -Fb basement wall per code (vertically every ten ft and from ceiling space) ELECTRICAL: -Support and protect wiring per code along I beam in basement **support the NM cables at least every 4.5 ft. Look above and near the furnace.Check this at final ***OK TO INSULATE
All Rough Inspection - Residential Passed 2/21/2018 at 9:25 AM 02/21/2018
Misc
Resolved
02/21/2018
FRAMING: -Fb basement wall per code (vertically every ten ft and from ceiling space) ELECTRICAL: -Support and protect wiring per code along I beam in basement **support the NM cables at least every 4.5 ft. Look above and near the furnace.Check this at final ***OK TO INSULATE
Driveway Inspection Partial 3/5/2018 at 1:50 PM 03/05/2018
Informational
03/05/2018
Jeremy Young 03/05/2018 2:26 PM John DiMauro and I Met the contractor on site. The driveway had sufficient compacted rock base of at least 4". He will add The expansion joint and make sure the cross slope is less than 2% for ADA purposes.
Sidewalk Inspection Partial 3/5/2018 at 1:50 PM 03/05/2018
PW-Misc
Informational
03/05/2018
Jeremy Young 03/05/2018 2:30 PM John DiMauro and I met the contractor on site. There was sufficient compacted rock base of at least 4". We verified the cross slopes of the sidewalk to comply with ADA standards. I will inspect after it is poured.
Driveway Inspection Passed 3/8/2018 at 10:50 AM 03/08/2018
Informational
03/08/2018
Jeremy Young 03/08/2018 11:00 AM The contractor poured the driveway. The cross slope is between 0-1.0% through the driveway for ADA requirements. There is 6" of concrete and the expansion joints have been added.
Sidewalk Inspection Passed 3/8/2018 at 10:50 AM 03/08/2018
PW-Misc
Informational
03/05/2018
Jeremy Young 03/05/2018 2:30 PM John DiMauro and I met the contractor on site. There was sufficient compacted rock base of at least 4". We verified the cross slopes of the sidewalk to comply with ADA standards. I will inspect after it is poured.
PW-Misc
Informational
03/08/2018
Jeremy Young 03/08/2018 11:04 AM The sidewalk is in compliance with ADA standards. The cross slope is 0-1% through all of the sidewalk. There is at least 4" of concrete for the sidewalk. It appears the correct concrete was used.
Occupancy Inspection - Codes Residential Failed 7/12/2018 7/12/2018 at 12:00 PM 07/12/2018
Misc
Corrective Action Required
07/12/2018
- no window screens - no ladder at egress in basement - missing door knob to in finished area basement - missing door knob at bedroom closet basement - missing door knob at closet bath in basement - bags are still on smoke detectors in able to test
Occupancy Inspection - Codes Residential Temporary C of O 7/17/2018 7/17/2018 at 9:30 AM 07/17/2018
Misc
Corrective Action Required
07/12/2018
-no ladder at egress in basement -no sod
Occupancy Inspection - Codes Residential Temporary C of O 07/17/2018
Misc
Corrective Action Required
07/17/2018
-no ladder at egress in basement -no sod
Occupancy Inspection - Codes Residential Full C of O 9/17/2018 at 9:20 AM 09/17/2018
Misc
Resolved
09/17/2018
-no ladder at egress in basement
Documents & Images
Date Uploaded File Type Document Name
09/19/2017 Letter Codes Residential Plan Review
09/20/2017 Letter Codes Residential Plan Review
10/05/2017 Receipt Receipt for transaction: 2017-006677
10/05/2017 Letter Codes Building Permit
10/05/2017 Plot Plan DOC100517-006
10/19/2017 Letter Inspection Summary
11/09/2017 Letter Inspection Summary
01/26/2018 Letter Inspection Summary
02/12/2018 Letter Inspection Summary
02/14/2018 Letter Inspection Summary
02/15/2018 Letter Inspection Summary
02/20/2018 Letter Inspection Summary
02/21/2018 Letter Inspection Summary
03/05/2018 Letter DE-Daily Inspection Summary
03/05/2018 Letter DE-Daily Inspection Summary
03/08/2018 Letter DE-Daily Inspection Summary
03/08/2018 Letter DE-Daily Inspection Summary
03/08/2018 Letter DE-Daily Inspection Summary
07/12/2018 Letter Inspection Summary
07/17/2018 Letter Codes Temporary Certificate of Occupancy
09/17/2018 Letter Field Certificate of Occupancy
09/18/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home