Permit Application Status

PRRES20172142


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20172142
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK FINISHED BASEMENT
06/27/2017
07/10/2017
12/24/2017
05/02/2018
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
KC CUSTOM HOMES, Address:406 NW DONOVAN RD, Phone:(816) 564-5149  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ADVANCED ELECTRICAL LLC, Address:PO BOX 1573, Phone:(816) 347-8187  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/03/2017 06/29/2017
Jonathon Hilton
Residential Plan Review Approved 07/03/2017 06/29/2017
Jonathon Hilton
Plot Plan Review Approved 06/29/2017 06/29/2017
Nick Lightner
Legal description
Resolved
06/29/2017

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. *Can you please change the description to 3rd plat.
Spot elevations
Resolved
06/29/2017

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. *N side of the house to the property corner is showing 1.5% slope. It needs to be atleast 2% If needed add show more drainage arrows on the N side of the house.
Misc
Resolved
06/29/2017

*Can you please provide the MBOE info on the plot plan.
Residential Plan Review Approved 06/29/2017 06/27/2017
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $869.33 $869.33 Paid 07/10/2017
8331504-EFHB Middle Big Creek, Full $569.16 $569.16 Paid 07/10/2017
8331507-Sewer Connection Fee $510.00 $510.00 Paid 07/10/2017
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 07/10/2017
8350015-Water Meter Fee $405.36 $405.36 Paid 07/10/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 07/10/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/25/2017 (10:30) 7/25/2017 07/25/2017
Erosion Control Inspection Residential Partial 07/25/2017
Underslab Plumbing Inspection - Residential Passed 8/28/2017 at 9:20 AM 08/28/2017
Sewer Service Inspection - R Passed 9/1/2017 (10:30) 9/1/2017 at 10:55 AM 09/01/2017
Water Service Inspection - R Partial 9/1/2017 at 11:00 AM 09/01/2017
Water Service Inspection - R Passed 9/6/2017 (8:00) 9/6/2017 at 8:15 AM 09/06/2017
Erosion Control Inspection Residential Failed 11/15/2017 at 2:25 AM 11/15/2017
Misc
Corrective Action Required
11/15/2017
Improve erosion control along curb at site to west of property that has been used as an entrance drive to this property.
Gas Piping Inspection - Residential Passed 11/15/2017 at 2:30 AM 11/15/2017
Gas Service Inspection - Residential Passed 11/15/2017 11/15/2017 at 2:35 AM 11/15/2017
All Rough Inspection - Residential Failed 11/15/2017 11/15/2017 at 2:45 AM 11/15/2017
Misc
Corrective Action Required
11/15/2017
1. Improve erosion control along curb at site to west of property that has been used as an entrance drive to this property before further inspection. 2. BSMT: Firestop tops of furred-out walls and every 10', measured horizontally, along walls (loose insulation not permitted). 3. BSMT: Furr out and firestop around DWV at ceiling level of bathroom. 4. BSMT: Firestop vertical-to-horizontal at southwest corner of bedroom. 5. BSMT: Three joists have been drilled within 2" of the bottom edge at the west bathroom. 6. BSMT: Slope & support DWV. 7. BSMT & 1st FLR: Firestop penetrations and gaps in solid blocking at ceilings and floors - multiple locations. 8. BSMT & 1st FLR: Sill-plate anchors. 9. 1st FLR: Appears that all LIB straps are missing; however, cannot confirm as prints on-site do not have a legend. 10. 1st FLR: Corner nailing - southeast and northeast corners. 11. 1st FLR: More than two consecutive load-bearing studs have been bored along the north wall. 12. 1st FLR: Slope & support DWV in attic. 13. 1st FLR: Interior garage portal straps to top plate. 14. 1st FLR: Missing joist hanger at attic access. 15. ROOF: Purlins are to be 2x10s, and are to be supported at 8'o.c. max, per plans. 16. ROOF: Hip-ridges are overspanned, per plans. 17. EXT: Complete electrical installation. 18. EXT: Siding nails are overdriven; ensure WSP spacing where needed. 19. EXT: Garage portal sheeting - nail to sill-plate at 3"o.c. max.
Electrical Service Inspection Passed 11/15/2017 11/15/2017 at 3:40 AM 11/15/2017
All Rough Inspection - Residential Failed 11/20/2017 11/20/2017 at 1:30 AM 11/20/2017
Misc
Corrective Action Required
11/15/2017
1. Improve erosion control along curb at site to west of property that has been used as an entrance drive to this property before further inspection. 2. BSMT: Firestop tops of furred-out walls and every 10', measured horizontally, along walls (loose insulation not permitted). 4. BSMT: Firestop vertical-to-horizontal at southwest corner of bedroom. 6. BSMT: Slope & support DWV. 10. 1st FLR: Corner nailing - southeast and northeast corners. 11. 1st FLR: More than two consecutive load-bearing studs have been bored along the north wall. 12. 1st FLR: Slope & support DWV in attic. 13. 1st FLR: Interior garage portal straps to top plate. 15. ROOF: Purlins are to be 2x10s, and are to be supported at 8'o.c. max, per plans. *Builder will submit revised plans. 16. ROOF: Hip-ridges are overspanned, per plans. 18. EXT: Siding nails are overdriven; ensure WSP spacing where needed.
Erosion Control Inspection Residential Partial 11/22/2017 at 10:35 AM 11/22/2017
Misc
Partial Correction
11/22/2017
Compliant. Maintain.
All Rough Inspection - Residential Failed 11/22/2017 11/22/2017 at 10:40 AM 11/22/2017
Misc
Corrective Action Required
11/20/2017
6. BSMT: Slope & support DWV. 11. 1st FLR: More than two consecutive load-bearing studs have been bored along the north wall. 12. 1st FLR: Slope & support DWV in attic. 18. EXT: Siding nails are overdriven; ensure WSP spacing where needed.
All Rough Inspection - Residential Failed 11/27/2017 11/27/2017 at 8:50 AM 11/27/2017
Misc
Corrective Action Required
11/22/2017
11. 1st FLR: More than two consecutive load-bearing studs have been bored along the north wall. *Pipe has been rerouted, but studs have not been repaired/sistered. OK to rock all but this location.
All Rough Inspection - Residential Passed 11/29/2017 11/29/2017 at 11:45 AM 11/29/2017
Misc
Resolved
11/29/2017
11. 1st FLR: More than two consecutive load-bearing studs have been bored along the north wall. *Pipe has been rerouted, but studs have not been repaired/sistered. OK to rock all but this location.
Piers/Caissons Inspection - Residential Passed 2/14/2018 2/14/2018 at 4:40 PM 02/14/2018
Driveway Inspection Failed 2/20/2018 at 9:33 AM 02/20/2018
Corrective Action Required
02/20/2018
Matt Munger 02/20/2018 9:38 AM Due to the weather I informed the contractor (left voicemail) that he will need to call back for an inspection another day to ensure proper compaction.
Driveway Inspection Partial 2/26/2018 2/26/2018 at 11:00 AM 02/27/2018
Informational
02/27/2018
Tom Chandler 02/26/2018 Inspected forms and compacted aggregate only.
Sidewalk Inspection Partial 2/26/2018 2/26/2018 at 11:10 AM 02/27/2018
Informational
02/27/2018
Tom Chandler 02/26/2018 Inspected foms and compacted aggregate only.
Driveway Inspection Passed 3/1/2018 at 2:40 PM 03/01/2018
Informational
03/01/2018
Tom Chandler 03/01/2018 2:43 PM Driveway has been completed and passed final inspection.
Sidewalk Inspection Passed 3/1/2018 at 2:45 PM 03/01/2018
Informational
03/01/2018
Tom Chandler 03/01/2018 2:44 PM Sidewalk has been completed and passed final inspection.
Occupancy Inspection - Codes Residential Full C of O 5/2/2018 at 7:55 AM 05/02/2018
Documents & Images
Date Uploaded File Type Document Name
06/27/2017 Letter Codes Residential Plan Review
06/27/2017 Letter Codes Residential Plan Review
07/10/2017 Receipt Receipt for transaction: 2017-004782
07/10/2017 Letter Codes Building Permit
07/10/2017 Plot Plan DOC071017-023
07/25/2017 Letter Inspection Summary
08/28/2017 Letter Inspection Summary
09/01/2017 Letter Inspection Summary
09/06/2017 Letter Inspection Summary
11/15/2017 Letter Inspection Summary
11/15/2017 Letter Inspection Summary
11/22/2017 Letter Inspection Summary
11/27/2017 Letter Inspection Summary
11/29/2017 Letter Inspection Summary
02/14/2018 Letter Inspection Summary
02/20/2018 Letter DE-Daily Inspection Summary
03/01/2018 Letter DE-Daily Inspection Summary
05/02/2018 Letter Field Certificate of Occupancy
05/03/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home