MAR INVESTMENTS INC
NEW SINGLE FAMILY
NEW SINGLE FAMILY FINISHED BASEMENT COVERED DECK STOP WORK ORDER generated on 07/06/2017 12:00 AM by username 'Mitch Plemmons'. STOP WORK ORDER removed on 07/13/2017 12:00 AM by username 'Sally Sarvadi'.
06/08/2017
06/21/2017
12/09/2017
11/08/2022
Locations
Contacts
MAR INVESTMENTS INC, Address:PO BOX 847  
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
ADVANCED ELECTRICAL LLC, Address:PO BOX 1573, Phone:(816) 347-8187  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/23/2017 06/21/2017
Jonathon Hilton
Plot Plan Review Approved 06/21/2017 06/19/2017
Jonathon Hilton
Spot elevations
Corrective Action Required
06/19/2017

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. *Can you please double check the slope from the rear, west and east of the lot. Also the NE corner of the house to the NE corner of the lot and also the NW corner of the house tot he NW corner of the lot. Make sure it is carrying at least 2% or more.
Residential Plan Review Approved 06/21/2017 06/19/2017
Jonathon Hilton
Plot Plan Review Approved 06/12/2017 06/19/2017
Nick Lightner
As-graded plot plan
Resolved
06/19/2017

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *Please provide in a bubble " AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING"
Spot elevations
Resolved
06/19/2017

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. *Can you please double check the slope from the rear, west and east of the lot. Also the NE corner of the house to the NE corner of the lot and also the NW corner of the house tot he NW corner of the lot. Make sure it is carrying at least 2% or more.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $971.04 $971.04 Paid 06/21/2017
8331504-EFHB Middle Big Creek, Full $535.68 $535.68 Paid 06/21/2017
8331507-Sewer Connection Fee $480.00 $480.00 Paid 06/21/2017
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 06/21/2017
8350015-Water Meter Fee $405.36 $405.36 Paid 06/21/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 06/21/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Partial 6/22/2017 6/22/2017 06/22/2017
Misc
Corrective Action Required
06/22/2017
NO ADDRESS NO PERMIT POSTED NO EROSION CONTROL FOOTING MEETS PLANS ON SITE.
Erosion Control Inspection Residential Failed 06/22/2017
Erosion Control Inspection Residential Partial 7/13/2017 7/13/2017 07/13/2017
Sewer Service Inspection - R Passed 7/13/2017 (1:15) 7/13/2017 07/13/2017
Water Service Inspection - R Passed 7/14/2017 (10:45) 7/14/2017 07/14/2017
Erosion Control Inspection Residential Failed 7/14/2017 07/14/2017
Erosion Control Inspection Residential Failed 7/18/2017 07/18/2017
Underslab Plumbing Inspection - Residential Failed 7/18/2017 7/18/2017 07/18/2017
Misc
Corrective Action Required
07/18/2017
NO INSPECTION - EROSION CONTROL / STREET CLEAN-UP
Underslab Plumbing Inspection - Residential Not Ready 7/21/2017 7/21/2017 07/21/2017
Misc
Corrective Action Required
07/18/2017
NOT READY - ALREADY COVERED WITH GRAVEL & STEEL
Underslab Plumbing Inspection - Residential Not Ready 7/24/2017 07/24/2017
Misc
Corrective Action Required
07/21/2017
NOT READY - ALREADY COVERED WITH GRAVEL & STEEL 7/24/17: Still covered - mainly drainage tile.
Erosion Control Inspection Residential Failed 7/24/2017 07/24/2017
Misc
Corrective Action Required
07/24/2017
Gravel needed at entry drive.
Underslab Plumbing Inspection - Residential Passed 7/25/2017 07/25/2017
Misc
Resolved
07/25/2017
NOT READY - ALREADY COVERED WITH GRAVEL & STEEL 7/24/17: Still covered - mainly drainage tile.
Erosion Control Inspection Residential Partial 07/25/2017
Misc
Resolved
07/25/2017
Gravel needed at entry drive.
Piers/Caissons Inspection - Residential Passed 8/29/2017 (9:45) 8/29/2017 at 10:05 AM 08/29/2017
Erosion Control Inspection Residential Partial 9/29/2017 at 10:20 AM 09/29/2017
Misc
Corrective Action Required
09/29/2017
Erosion control compliant. Maintain.
Gas Service Inspection - Residential Passed 9/29/2017 9/29/2017 at 10:25 AM 09/29/2017
Gas Piping Inspection - Residential Passed 9/29/2017 at 10:35 AM 09/29/2017
Electrical Service Inspection Passed 9/29/2017 9/29/2017 at 10:40 AM 09/29/2017
All Rough Inspection - Residential Failed 9/29/2017 9/29/2017 at 10:50 AM 09/29/2017
Misc
Corrective Action Required
09/29/2017
1. BSMT: Anchor columns. 2. BSMT: Joist hanger over egress window. 3. BSMT: BOCA plate at san-swr main. 4. BSMT: Support DWV over entry door to unfinished area. 5. BSMT: Firestop change in ceiling height at entry door to unfinished area. 6. BSMT: Firestop over deadspace behind shower. 7. GARAGE: Interior portal straps. 8. GARAGE: Security blocking at personnel door. 9. GARAGE: Firestop top of DWV chase. 10. GARAGE: Sill plate anchors. 11. 1st FLR: Support DWV over dining room. 12. 1st FLR: Firestop top of return air chase - vert-to-horiz. 13. 2nd FLR: Joist hangers at BR #s 3 & 4. 14. 2nd FLR: Nail siding. 15. 2nd FLR: More than two consecutive studs bored at guest bath. 16. Slope and support DWV in attic. 17. 2nd FLR: Fully install/nail snow blocking.
Erosion Control Inspection Residential Partial 10/4/2017 at 10:15 AM 10/04/2017
Misc
Corrective Action Required
09/29/2017
Erosion control compliant. Maintain.
All Rough Inspection - Residential Failed 10/4/2017 10/4/2017 at 10:20 AM 10/04/2017
Misc
Corrective Action Required
10/04/2017
2. BSMT: Joist hanger over egress window. 4. BSMT: Support DWV over entry door to unfinished area. 5. BSMT: Firestop change in ceiling height at entry door to unfinished area. 6. BSMT: Firestop over deadspace behind shower. 11. 1st FLR: Support DWV over dining room. 14. 2nd FLR: Nail siding. 17. 2nd FLR: Fully install/nail snow blocking.
All Rough Inspection - Residential Failed 10/10/2017 10/10/2017 at 8:20 AM 10/10/2017
Misc
Corrective Action Required
10/04/2017
4. BSMT: Support DWV over entry door to unfinished area. 5. BSMT: Firestop change in ceiling height at entry door to unfinished area. *Either solid block, or insulation should extend 16" below level where solid blocking would go. 6. BSMT: Firestop over deadspace behind shower. *solid blocking 14. 2nd FLR: Nail siding. *east and west walls 17. 2nd FLR: Fully install/nail snow blocking. *master closet
All Rough Inspection - Residential Failed 10/13/2017 at 2:50 AM 10/13/2017
Misc
Corrective Action Required
10/10/2017
6. BSMT: Firestop over deadspace behind shower. *solid blocking 14. 2nd FLR: Nail siding. *east and west walls 17. 2nd FLR: Fully install/nail snow blocking. *master closet
All Rough Inspection - Residential Passed 10/17/2017 10/17/2017 at 11:10 AM 10/17/2017
Misc
Resolved
10/17/2017
6. BSMT: Firestop over deadspace behind shower. *solid blocking 14. 2nd FLR: Nail siding. *east and west walls 17. 2nd FLR: Fully install/nail snow blocking. *master closet
Driveway Inspection Partial 12/5/2017 12/5/2017 at 9:25 AM 12/05/2017
Informational
12/05/2017
Tom Chandler 12/05/2017 9:28 AM Inspected forms and compacted aggregate only. Contractor notified to blanket and maintain temperature throughout cure process.
Driveway Inspection Passed 12/11/2017 at 2:45 PM 12/11/2017
Informational
12/11/2017
Tom Chandler 12/11/2017 2:48 PM Driveway has been completed and passed final inspection.
Plot Plan Inspection Passed 04/27/2018
Occupancy Inspection - Codes Residential Failed 11/2/2018 11/2/2018 at 10:01 AM 11/02/2018
Misc
Corrective Action Required
11/02/2018
• Secondary locking device not installed at sliding glass doors • Access panel at spa tub in master bath has no access • Window screens • I gfci outlet at sub panel will not reset • Under stair storage area must be sheet rocked • Seal sump pump penetration outside • Discharge sump at least 36” away from house • Random hole on east side of house needs to be covered and sealed • Grade at northeast side of house within 6” of siding • As graded plot plan is required • Irrigation permit required
Investigation Inspection Complete 5/9/2019 05/09/2019
Documents & Images
Date Uploaded File Type Document Name
06/09/2017 Letter Codes Residential Plan Review
06/21/2017 Receipt Receipt for transaction: 2017-004121
06/21/2017 Letter Codes Building Permit
06/22/2017 Letter Inspection Summary
06/23/2017 Plot Plan DOC062317-002
07/06/2017 Letter Stop Work Order
07/13/2017 Letter Inspection Summary
07/14/2017 Letter Inspection Summary
07/18/2017 Letter Inspection Summary
07/21/2017 Letter Inspection Summary
07/24/2017 Letter Inspection Summary
07/25/2017 Letter Inspection Summary
08/29/2017 Letter Inspection Summary
09/29/2017 Letter Inspection Summary
10/04/2017 Letter Inspection Summary
10/10/2017 Letter Inspection Summary
10/13/2017 Letter Inspection Summary
10/17/2017 Letter Inspection Summary
12/05/2017 Letter DE-Daily Inspection Summary
12/11/2017 Letter DE-Daily Inspection Summary
04/27/2018 Letter Inspection Summary
04/27/2018 Plot Plan DOC042718-04272018141700
11/02/2018 Letter Inspection Summary
03/22/2019 Letter Codes 140 Day Letter
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home