Summary
PRRES20170810
Building Permit - Residential
Certificate of Occupancy
NICK ZVACEK CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY
03/22/2017
05/05/2017
05/04/2018
Locations
Contacts
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR  
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/03/2017 05/01/2017
Jonathon Hilton
Plot Plan Review Rejected 03/24/2017 04/26/2017
Nick Lightner
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,083.82 $1,083.82 Paid 05/05/2017
8331504-EFHB Middle Big Creek, Full $636.12 $636.12 Paid 05/05/2017
8331507-Sewer Connection Fee $570.00 $570.00 Paid 05/05/2017
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 05/05/2017
8350015-Water Meter Fee $405.36 $405.36 Paid 05/05/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 05/05/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/12/2017 (1:30) 5/12/2017 05/12/2017
Sewer Service Inspection - R Passed 6/14/2017 (2:15) 6/14/2017 06/14/2017
Underslab Plumbing Inspection - Residential Passed 6/15/2017 6/15/2017 06/15/2017
Water Service Inspection - R Passed 6/19/2017 (1:15) 6/19/2017 06/19/2017
Piers/Caissons Inspection - Residential Passed 8/29/2017 (8:00) 8/29/2017 at 8:25 AM 08/29/2017
All Rough Inspection - Residential Not Ready 9/8/2017 09/08/2017
Misc
Resolved
09/11/2017
NO PRINTS
All Rough Inspection - Residential Failed 9/11/2017 9/11/2017 at 8:50 AM 09/11/2017
Misc
Corrective Action Required
09/11/2017
1. BSMT & 2nd FLR: Elec nail guards where marked with red 'X'. 2. BSMT: Firestop along tops of walls and at end of ceiling furr-out. 3. BSMT: Anchor columns. 4. 1st FLR: Firestop tops of DWV chases at rear of Living Room & Garage. 5. 1st FLR: Notched floor joist over rear of Living Room. 6. 1st FLR: Nail stud shoes at kitchen. 7. 2nd FLR: More than 2 consecutive studs bored at master bath.
Electrical Service Inspection Passed 9/14/2017 9/14/2017 at 8:40 AM 09/14/2017
Gas Piping Inspection - Residential Passed 9/14/2017 at 8:45 AM 09/14/2017
Gas Service Inspection - Residential Passed 9/14/2017 9/14/2017 at 8:50 AM 09/14/2017
All Rough Inspection - Residential Failed 9/14/2017 9/14/2017 at 8:55 AM 09/14/2017
Misc
Corrective Action Required
09/11/2017
2. BSMT: Firestop at ends of ceiling furr-out. (*still missing near top of stairs and near shower) 4. 1st FLR: Firestop tops of DWV chases at rear of Living Room & Garage.
All Rough Inspection - Residential Failed 9/18/2017 9/18/2017 at 8:25 AM 09/18/2017
Misc
Corrective Action Required
09/14/2017
*DC 9/18: Met framers on-site - solid blocking looks good, but still need to fill gaps with foam and/or wool at the two main-floor locations and behind the shower in the basement. (Location in basement, by stairs is OK now.) OK to insulate. 2. BSMT: Firestop at ends of ceiling furr-out. (*still missing near top of stairs and near shower) 4. 1st FLR: Firestop tops of DWV chases at rear of Living Room & Garage.
Miscellaneous Inspection Passed 9/19/2017 at 12:20 PM 09/19/2017
All Rough Inspection - Residential Passed 9/19/2017 at 12:25 PM 09/19/2017
Misc
Resolved
09/19/2017
*DC 9/18: Met framers on-site - solid blocking looks good, but still need to fill gaps with foam and/or wool at the two main-floor locations and behind the shower in the basement. (Location in basement, by stairs is OK now.) OK to insulate. 2. BSMT: Firestop at ends of ceiling furr-out. (*still missing near top of stairs and near shower) 4. 1st FLR: Firestop tops of DWV chases at rear of Living Room & Garage.
Driveway Inspection Passed 10/13/2017 11/6/2017 at 10:10 AM 11/06/2017
Informational
11/06/2017
Tom Chandler 11/06/2017 10:13 AM Driveway has been completed and passed final inspection.
Plot Plan Inspection Passed 4/4/2018 at 1:30 PM 04/04/2018
Corrective Action Required
04/04/2018
There is a discrepancy with the NW proprty corner elevation on lot 91. Lot 92 elevation at the NE poperty corner is not matching. These two lots were surveyed by the same company.
Occupancy Inspection - Codes Residential Failed 4/10/2018 4/10/2018 04/10/2018
R311 MEANS OF EGRESS
Corrective Action Required
04/10/2018
- SUMP PUMP DISCHARGE - LAWN SPRINKLER PERMIT -NO OUTLETS MSTR VANITY -MSTR TUB ACCESS -SMOKE HANGING FROM CEILING NE BED. -NO WALL OUTLET, WALL WITH THERMOSTAT 1ST FLOOR -LABEL SMOKES AT PANEL. -CUT DRAIN PIPE AND CLEAN OUT WINDOW WELL. -NO ANTI SIPHON BSMT HOSE BIB -SELF CLOSING GARAGE DOOR HINGE -NO HANDRAIL IN GARAGAE - HOOD NOT WIRED OR INSTALLED -2ND LOCKING DEVISE FOR SLIDING DOOR - NO REAR STEPS.
Occupancy Inspection - Codes Residential Full C of O 5/4/2018 5/4/2018 at 10:35 AM 05/04/2018
R311 MEANS OF EGRESS
Resolved
05/04/2018
- SUMP PUMP DISCHARGE - LAWN SPRINKLER PERMIT -NO OUTLETS MSTR VANITY -MSTR TUB ACCESS -SMOKE HANGING FROM CEILING NE BED. -NO WALL OUTLET, WALL WITH THERMOSTAT 1ST FLOOR -LABEL SMOKES AT PANEL. -CUT DRAIN PIPE AND CLEAN OUT WINDOW WELL. -NO ANTI SIPHON BSMT HOSE BIB -SELF CLOSING GARAGE DOOR HINGE -NO HANDRAIL IN GARAGAE - HOOD NOT WIRED OR INSTALLED -2ND LOCKING DEVISE FOR SLIDING DOOR - NO REAR STEPS.
Documents & Images
Date Uploaded File Type Document Name
05/05/2017 Receipt Receipt for transaction: 2017-001867
05/05/2017 Letter Codes Building Permit
05/09/2017 Plot Plan DOC050917-010
05/12/2017 Letter Inspection Summary
06/14/2017 Letter Inspection Summary
06/15/2017 Letter Inspection Summary
06/19/2017 Letter Inspection Summary
08/29/2017 Letter Inspection Summary
09/08/2017 Letter Inspection Summary
09/11/2017 Letter Inspection Summary
09/14/2017 Letter Inspection Summary
09/18/2017 Letter Inspection Summary
09/19/2017 Letter Inspection Summary
11/06/2017 Letter DE-Daily Inspection Summary
04/10/2018 Letter Inspection Summary
05/07/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home