Permit Application Status

PRRES20170130


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20170130
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNCOVERED DECK
01/20/2017
01/25/2017
09/15/2017
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/24/2017 01/24/2017
Jonathon Smith
Plot Plan Review (P&D) Approved 01/24/2017 01/20/2017
Christina Stanton
Residential Plan Review Approved 01/24/2017 01/20/2017
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,305.67 $1,305.67 Paid 01/25/2017
8331507-Sewer Connection Fee $690.00 $690.00 Paid 01/25/2017
Water Tap Fee $3,310.00 $3,310.00 Paid 01/25/2017
Water Meter Fee $405.36 $405.36 Paid 01/25/2017
Right of Way Permit Fee $75.00 $75.00 Paid 01/25/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/7/2017 (1:30) 2/7/2017 02/07/2017
Sewer Service Inspection - R Passed 2/17/2017 (8:30) 2/17/2017 02/17/2017
Water Service Inspection - R Passed 2/17/2017 (10:15) 2/17/2017 02/17/2017
Underslab Plumbing Inspection - Residential Passed 2/28/2017 2/28/2017 02/28/2017
All Rough Inspection - Residential Not Ready 6/7/2017 6/7/2017 06/07/2017
Misc
Corrective Action Required
06/07/2017
1. Sill plate at garage portal not nailed 3" o.c. Nail garage portal 3" o.c. 2. Nail all siding per manufacturer's instructions. 3. Rear grade, required to have minimum 6" clearance from grade, will check at final. 4. Next to deck door, overnotched stud for exterior light. No security blocking. 5. Fireblocking integrity, loose insulation is no acceptable unless packed tight. 6. Anchor all columns and sill plates per code. 7. Support all plumbing 4' o.c. 8. Missing roof truss hangers, check packet. 9. Fireblock basement wall next to stairs. 10. Security block walkout door. 11. No floor joist layout included with plan packet. Not a complete inspection. Do not insulate.
Gas Service Inspection - Residential Passed 6/7/2017 6/7/2017 06/07/2017
Gas Piping Inspection - Residential Passed 6/7/2017 6/7/2017 06/07/2017
Electrical Service Inspection Passed 6/7/2017 6/7/2017 06/07/2017
All Rough Inspection - Residential Not Ready 6/16/2017 6/16/2017 06/16/2017
Misc
Corrective Action Required
06/07/2017
1. Sill plate at garage portal not nailed 3" o.c. Nail garage portal 3" o.c. 2. Nail all siding per manufacturer's instructions. 3. Rear grade, required to have minimum 6" clearance from grade, will check at final. 4. Next to deck door, overnotched stud for exterior light. No security blocking. 5. Fireblocking integrity, loose insulation is no acceptable unless packed tight. 6. Anchor all columns and sill plates per code. 7. Support all plumbing 4' o.c. 8. Missing roof truss hangers, check packet. 9. Fireblock basement wall next to stairs. 10. Security block walkout door. 11. No floor joist layout included with plan packet. Not a complete inspection. Do not insulate.
All Rough Inspection - Residential Failed 6/20/2017 6/20/2017 06/20/2017
Misc
Corrective Action Required
06/16/2017
1. Sill plate at garage portal not nailed 3" o.c. Nail garage portal 3" o.c. 3. Rear grade, required to have minimum 6" clearance from grade, will check at final. 4. Next to deck door, overnotched stud for exterior light. No security blocking. 6. Anchor all sill plates per code. (BASEMENT, BOLT WITHIN 12" OF BREAK IN SILL AND MINIMUM 2 PER PLATE.) 8. Missing roof truss hangers, check packet. Do not insulate.
All Rough Inspection - Residential Failed 6/21/2017 6/21/2017 06/21/2017
Misc
Corrective Action Required
06/20/2017
1. Sill plate at garage portal not nailed 3" o.c. Nail garage portal 3" o.c. 3. Rear grade, required to have minimum 6" clearance from grade, will check at final. 6. Anchor all sill plates per code. (BASEMENT, BOLT WITHIN 12" OF BREAK IN SILL AND MINIMUM 2 PER PLATE.) 8. Missing roof truss hangers, check packet. Do not insulate.
All Rough Inspection - Residential Failed 6/21/2017 06/21/2017
Misc
Corrective Action Required
06/21/2017
1. Sill plate at garage portal not nailed 3" o.c. Nail garage portal 3" o.c. 3. Rear grade, required to have minimum 6" clearance from grade, will check at final. OK to insulate.
Driveway Inspection Partial 6/27/2017 6/27/2017 06/27/2017
Informational
06/27/2017
John DiMauro 06/27/2017 10:09 AM Forms are up and rock is compacted.
Driveway Inspection Passed 6/29/2017 06/29/2017
Informational
06/29/2017
John DiMauro 06/29/2017 1:51 PM
All Rough Inspection - Residential Partial 07/18/2017
Misc
Partial Correction
07/18/2017
3. Rear grade, required to have minimum 6" clearance from grade, will check at final.
All Rough Inspection - Residential Passed 09/05/2017
Misc
Partial Correction
07/18/2017
3. Rear grade, required to have minimum 6" clearance from grade, will check at final.
Occupancy Inspection - Codes Residential Failed 9/5/2017 9/5/2017 09/06/2017
Misc
Corrective Action Required
09/05/2017
-INSTALL SOD, SPLASHBLOCKS -VEGETATION TO THE LOT TO THE SOUTH SHOULD BE ESTABLISHED, EROSION CONTROL SHALL BE IN PLACE FOR TEMP C OF O
Occupancy Inspection - Codes Residential Temporary C of O 9/7/2017 9/7/2017 09/07/2017
Misc
Corrective Action Required
09/06/2017
-VEGETATION TO THE LOT TO THE SOUTH SHOULD BE ESTABLISHEDSHALL BE IN PLACE FOR TEMP C OF O
Occupancy Inspection - Codes Residential Full C of O 9/15/2017 9/15/2017 at 9:15 AM 09/15/2017
Misc
Resolved
09/15/2017
-VEGETATION TO THE LOT TO THE SOUTH SHOULD BE ESTABLISHEDSHALL BE IN PLACE FOR TEMP C OF O
Documents & Images
Date Uploaded File Type Document Name
01/25/2017 Receipt Receipt for transaction: 2017-000222
01/25/2017 Letter Codes Building Permit
01/27/2017 Plot Plan DOC012617-010
02/06/2017 Engineer Report/Study DOC020617-005
02/07/2017 Letter Inspection Summary
02/08/2017 Engineer Report/Study DOC020817-014
02/17/2017 Letter Inspection Summary
02/17/2017 Letter Inspection Summary
02/28/2017 Letter Inspection Summary
06/07/2017 Letter Inspection Summary
06/20/2017 Letter Inspection Summary
06/21/2017 Letter Inspection Summary
06/21/2017 Letter Inspection Summary
06/27/2017 Letter PW-Daily Inspection Summary
06/29/2017 Letter PW-Daily Inspection Summary
07/18/2017 Letter Inspection Summary
09/06/2017 Letter Inspection Summary
09/07/2017 Letter Codes Temporary Certificate of Occupancy
09/15/2017 Letter Field Certificate of Occupancy
09/18/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home