Permit Application Status

PRRES20161251


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20161251
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
NEW HOUSE WITH COVERED DECK - FININSHED BASEMENT
05/31/2016
06/06/2016
09/07/2018
Locations
Contacts
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Not shown for privacy reasons.
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 06/02/2016 06/06/2016
Development Center
Plot Plan Review (P&D) Approved 06/02/2016 06/03/2016
Hector Soto Jr.
Plot Plan Review Approved 06/03/2016
James Fletchall
Plot Plan Review Rejected 06/02/2016 06/02/2016
James Fletchall
Plot Plan Review (P&D) Rejected 06/02/2016 05/31/2016
Hector Soto Jr.
DE Corps of Engineers
Corrective Action Required
05/31/2016

Label 5' sidewalk.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,269.65 $1,269.65 Paid 06/06/2016
Right of Way Permit Fee $75.00 $75.00 Paid 06/06/2016
8331507-Sewer Connection Fee $630.00 $630.00 Paid 06/06/2016
Water Tap Fee $3,214.00 $3,214.00 Paid 06/06/2016
Water Meter Fee $377.18 $377.18 Paid 06/06/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/30/2016 (1:30) 6/30/2016 06/30/2016
Sewer Service Inspection - R Passed 7/28/2016 (11:00) 7/28/2016 07/28/2016
Water Service Inspection - R Partial 7/28/2016 07/28/2016
Water Service Inspection - R Passed 8/2/2016 (9:30) 8/2/2016 08/02/2016
Underslab Plumbing Inspection - Residential Passed 8/5/2016 8/5/2016 08/05/2016
All Rough Inspection - Residential Failed 2/9/2017 2/9/2017 02/09/2017
Misc
Corrective Action Required
02/09/2017
-INSTALL HANGER FOR LVL OVER 1ST FLOOR BEDROOM -FIREBLOCK DEAD SPACE BETWEEN GARAGE AND SHOWER -SOLID BLOCK OVER REAR CANTILEVER GREAT ROOM -WINDER TREAD TO SECOND FLOOR, MAKE SURE YOU HAVE 6" USABLE SPACE AT ANY POINT -NAIL GIRDER TRUSSES -BASEMENT, FIREBLOCK VERTICALLY EVERY 10 FEET OKAY TO INSULATE
Gas Service Inspection - Residential Failed 2/9/2017 2/9/2017 02/09/2017
Misc
Corrective Action Required
02/09/2017
NOT ENOUGH TEST PRESSURE
Electrical Service Inspection Passed 2/9/2017 2/9/2017 02/09/2017
Investigation Inspection Complete 02/09/2017
Gas Service Inspection - Residential Passed 2/14/2017 2/14/2017 02/14/2017
Misc
Resolved
02/14/2017
NOT ENOUGH TEST PRESSURE
All Rough Inspection - Residential Failed 2/21/2017 2/21/2017 02/21/2017
Misc
Corrective Action Required
02/09/2017
-INSTALL HANGER FOR LVL OVER 1ST FLOOR BEDROOM **NAIL THE ANGLE HANGER -FIREBLOCK DEAD SPACE BETWEEN GARAGE AND SHOWER **FB FROM JOIST SPACE. ALSO, INSULATION USED AS FB MATERIAL MUST BE PACKED TIGHT -WINDER TREAD TO SECOND FLOOR, MAKE SURE YOU HAVE 6" USABLE SPACE AT ANY POINT **CHECK ON FINAL -NAIL GIRDER TRUSSES **NAIL THE GIRDERS PER TRUSS DETAIL. NAIL THE UPPER CHORD AS WELL AS THE UPPER PART OF THE WEB MEMEBERS OKAY TO INSULATE
All Rough Inspection - Residential Partial 2/23/2017 2/23/2017 02/23/2017
Misc
Corrective Action Required
02/21/2017
-WINDER TREAD TO SECOND FLOOR, MAKE SURE YOU HAVE 6" USABLE SPACE AT ANY POINT **CHECK ON FINAL
Driveway Inspection Partial 2/27/2017 02/27/2017
Driveway Inspection Passed 3/6/2017 03/06/2017
PW-Misc
Informational
03/06/2017
Tom Chandler 03/06/2017 11:39 AM Driveway has been completed and passed final inspection.
Sidewalk Inspection Partial 4/24/2017 4/24/2017 04/24/2017
Informational
04/24/2017
Tom Chandler 04/24/2017 4:19 PM Inspected forms only.
Sidewalk Inspection Passed 4/28/2017 04/27/2017
Informational
04/27/2017
Tom Chandler 04/27/2017 10:00 AM Sidewalk has been completed and passed final inspection.
Occupancy Inspection - Codes Residential Not Ready 5/26/2017 5/26/2017 05/26/2017
Misc
Corrective Action Required
05/26/2017
NOT MAKING OBVIOUS PUNCH LIST ITEMS THIS IS NOT READY FOR INSPECTION **FYI, CEDAR POSTS IN CONCRETE FOR THE DECK WILL HAVE TO BE REPLACED**
Occupancy Inspection - Codes Residential Failed 9/15/2017 9/15/2017 at 10:50 AM 09/15/2017
Misc
Corrective Action Required
05/26/2017
-CEDAR POSTS IN CONCRETE FOR THE DECK -REAR GRADE SOUTH OF PATIO NEEDS 6" FALL FOR FIRST 10' FROM FOUNDATION. NEED 6" CLEARANCE FROM SOIDING TO GRADE. -SECURITY SCREWS REAR DOORS -FIRE PROTECTION OF FLOORS IN UNFINISHED AREA -HYDRO TUB MOTOR ACCESS
Occupancy Inspection - Codes Residential Failed 2/27/2018 2/27/2018 at 10:35 AM 02/27/2018
Misc
Corrective Action Required
09/15/2017
-REAR GRADE SOUTH OF PATIO NEEDS 6" FALL FOR FIRST 10' FROM FOUNDATION. NEED 6" CLEARANCE FROM SOIDING TO GRADE. Rear grade still doesn't have fall. Trenched in and landscape rock created ponding and water will sit next to footing. re grade rear yard.
Occupancy Inspection - Codes Residential Full C of O 09/07/2018
Misc
Resolved
09/07/2018
-REAR GRADE SOUTH OF PATIO NEEDS 6" FALL FOR FIRST 10' FROM FOUNDATION. NEED 6" CLEARANCE FROM SOIDING TO GRADE. Rear grade still doesn't have fall. Trenched in and landscape rock created ponding and water will sit next to footing. re grade rear yard.
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit